PRODUCT SPECIFICATIONS > INSTRUMENTATION

NOSHOK

Series 615 Pressure Transmitter

High Accuracy, Vacuum To 120,000 PSIG & 300 PSIA

DESCRIPTION

NOSHOK Series 615 Pressure Transducers are designed for heavy duty applications requiring high accuracy and durability. Utilizing diffused semiconductor or sputtered Thin Film technology, these transducers are stable, accurate, shock resistant, and extremely durable.

The durability is coupled with the mechanical integrity of the case, process connection, and wetted parts constructed of corrosion resistant stainless steel.

Available in a wide variety of electrical and process configurations, the Series 615 Pressure Transducers are the choice for heavy duty applications.

A final electrical output and calibration inspection is performed on all NOSHOK transducers prior to shipment to ensure 100% "out of the box" reliability.

FEATURES

  • Advanced diffused semi-conductor and sputtered thin film sensor for maximum stability
  • High accuracy and long term stability
  • Ranges from vacuum to 120,000 psi
  • Corrosion resistant stainless steel construction
  • Span and zero adjustments
 Hydraulic & Pneumatic Systems	
 Industrial Machinery	
 Pumps & Compressors
 HVAC
 Water Management
 Laboratory & Test
 Medical Equipment
 Railroad Equipment
 Marine
 Power Generation

SPECIFICATIONS

Output signals: 4mA to 20mA, 2-wire; 1 Vdc to 5Vdc, 1 Vdc to 6Vdc, 1 Vdc to 11 Vdc, 
	3-wire; 0Vdc to 5Vdc and 0 Vdc to 10 Vdc, 3-wire; 0 Vdc to 5 Vdc and 0 Vdc to 10 Vdc, 4-wire
Pressure ranges: Standard gauge ranges from vacuum to 120,000 psig; 
	Standard absolute ranges from 15 psia to 300 psia
Proof pressure: 3 times Full Scale for ranges 0 psi to 2psi through 0 psi to 200 psi
	1.75 times Full Scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
	1.5 times Full Scale for 0 psi to15,000 psi range
	1.2 times Full Scale for ranges 0 psi to 20,000 psi through 0 psi to120,000 psi
Burst pressure: 3.8 times Full Scale for ranges 0 psi to 2 psi through 0 psi to 200 psi
	4 times Full Scale for ranges 0 psi to 300 psi through 0 psi to10,000 psi
	3 times Full Scale for 0 psi to15,000 psi range
	1.5 times Full Scale for ranges 0 psi to 20,000 psi through 0 psi to120,000 psi
Accuracy: ±0.25% Full Scale (best fit straight line); Includes the combined effects of linearity, 
	hysteresis and repeatability; ±0.125% Full Scale (optional)
Repeatability: < ±0.05% Full Scale
Hysteresis: < ±0.1% Full Scale
Stability: < ±0.2% Full Scale for 1 year, nonaccumulating
Power supply: 10Vdc to 30 Vdc for current output, unregulated ;14 Vdc to 
	30 Vdc for voltage output, unregulated
Load limitations: < (VPower—10)/0.020 Amp for 4mA to 20mA
	>10,000 Ohms for 0 Vdc to 10Vdc, 3-wire
	>5,000 Ohms for 0 Vdc to 5Vdc, 3-wire
Wetted materials: 316 stainless steel for vacuum through 300psi; 17-4PH stainless steel 
	sensing diaphragm and 316 stainless steel process connection for higher ranges
Housing materials: 316 stainless steel
Temperature ranges: Compensated 32°F to 175°F/0°C to 80°C
Effect: ±0.01%/°F for zero and span
Storage: -40°F to 212°F/-40°C to 100°C
Media: -20°F to 212°F/-30°C to 100°C
Ambient: -15°F to 175°F/-10°C to 80°C
Response time: Less than 1ms (between 10%and 90% Full Scale)
Durability: >100,000,000 Full Scale cycles
Adjustment: ±10% Full Scale for zero and span
Environmental protection: NEMA4X, IP65(IEC529)
Electromagnetic rating: CE compliant to EMC norm EN61326:1997/A1:1998RFI, EMI and ESD protection
Electrical protection: Reverse polarity over voltage and short circuit protection
Shock: Less than ±0.05% Full Scale effect or 1000 g's @20 ms on any axis
Vibration: Less than ±0.01% Full Scale effect for 15 g's@0 Hz to 2000 Hz on any axis
Weight: Approximately 7.2oz.
Series 625 Intrinsically Safe Pressure Transmitter

2-Wire Wiring
  Hirschmann Cable M12 Bendix
+ Supply 1 Red 1 A
+ Output 2 Black 3 B

3-Wire Wiring
  Hirschmann Cable M12 Bendix
+ Supply 1 Red 1 A
Common 2 Black 3 B
+ Output 3 White 4 C


ORDERING INFORMATION

ORDER NUMBER:615-A-B-C-D-E
EXAMPLE: 615-2-1-1-2-8

PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS
Model A= Range
PSIG PSIG PSIG PSIG PSIA
Range Code Range Range Code Range Range Code Range Range Code Range Range Code Range
615 30V -30 in. Hg to 0 PSIG 5 0 to5 PSIG 600 0 to 600 PSIG 15000 0 to 15,000 PSIG 15A 0 to 15 PSIA
30/15 -30 in. Hg to 15 PSIG 10 0 to10 PSIG 750 0 to 750 PSIG 20000 0 to 20,000 PSIG 30A 0 to 30 PSIA
30/30 -30 in. Hg to 30 PSIG 15 0 to 15 PSIG 1000 0 to 1000 PSIG 30000 0 to 30,000 PSIG 60A 0 to 60 PSIA
30/60 -30 in. Hg to 60 PSIG 30 0 to30 PSIG 2000 0 to 2000 PSIG 40000 0 to 40,000 PSIG 100A 0 to 100 PSIA
30/100 -30 in. Hg to 100 PSIG 60 0 to60 PSIG 3000 0 to 3,000 PSIG 50000 0 to 50,000 PSIG 150A 0 to 150 PSIA
30/150 -30 in. Hg to 150 PSIG 100 0 to 100 PSIG 4000 0 to 4,000 PSIG 60000 0 to 60,000 PSIG 200A 0 to 200 PSIA
30/200 -30 in. Hg to200 PSIG 150 0 to 150 PSIG 5000 0 to 5,000 PSIG 75000 0 to 75,000 PSIG 300A 0 to 300 PSIA
30/300 -30 in. Hg to 300 PSIG 200 0 to 200 PSIG 6000 0 to 6,000 PSIG 85000 0 to 85,000 PSIG    
2 0 to 2 PSIG 300 0 to 300 PSIG 7500 0 to 7,500 PSIG 100000 0 to 10,0000 PSI
3 0 to 3 PSIG 500 0 to 500 PSIG 10000 0 to 10,000 PSIG 120000 0 to 120,000 PSIG

B= Accuracy C= Output Signals D= Process Connection E= Electrical Connection
1 ±0.5% 1 = 4mA to 20mA, 2-wire 2 = 1/4" NPT Male 1 = 36"cable (connected to option 8)
2 ±0.25% 2=  0 to 5Vdc, 3-wire 6 = 9/16"-18 aminco (Std on 30000 to 120000 psig) 3 = 6-pin Bendix
  3 = 1 to 5Vdc, 3-wire 8 = 1/2" NPT Male 6 = 1/2"NPT conduit w/36" cable
4 = 1 to 6 Vdc,3-wire*   8 = Hirschmann (DIN EN175301-803 Form A)
5 = 0 to10 Vdc,3-wire 14 = Hirschmann type with1/2"NPT female conduit
6 = 1 to11 Vdc, 3-wire* 25 = M12x14-pin
  36 = Integral 36" Cable
*Ranges up to 0 psig to 60000 psig

Series 615 Pressure Transmitter