The complete lack of moving parts of this insertion flow sensor is the source of its reliability. There is no rotor to stop turning in dirty water and there are no bearings to wear out. A rapidly reversing magnetic field is produced in the lower housing, and as the fluid moves through this field a voltage is generated. This tiny voltage is measured and translated into a frequency signal which is proportional to flow rate. This square wave signal can be sent directly to a PLC or other control, or can be converted using any of the associated family of indicators and converters.
A modular system of electronics can be attached directly to the flow sensor or remotely mounted. The FT420 provides full indication of rate and total, plus 4- 20 mA output. The AO55 provides a 4-20 mA output, and the FS30 can be used as a precise setpoint flow switch.
The installation fitting of the EX sensor is standard male NPT, and can be directly threaded into ordinary saddles or threaded weld fittings. The EX115 and 215 include an isolation valve, allowing hot-tap installation or installation and removal under pressure. The standard isolation valve is Bronze, but a 316 Stainless Steel valve is available as an option if needed.
Power: 12 - 24 Vdc, 250 mA
Flow Range: 0.2 to 20 ft/sec (.06 - 6.09 m/sec)
Fitting Size: EX101, 201 = 1½" MNPT; EX115, 215 = 2" MNPT
Installation Pipe Sizes: EX101/EX115, 3" to 10" pipe; EX201/EX215,
10" to 48"
Temperature: Ambient, 0° to 180°F (-17 - 82°C); Fluid,
32° to 212°F (0° - 100°C)
Pressure: 200 psi (13.8 bar)
Minimum Conductivity: 20 microsiemens/cm
Mechanical Materials: 316 SS or Brass
Electrodes: Carbon Graphite
Electrode plate: PVDF
Housing: Cast powder-coated aluminum
O-rings: EPDM
Calibration Accuracy: 1% of full scale
Output: Square wave pulse, opto-isolated, 500 Hz @ 20 ft/sec is standard.
4-20 mA, rate and total indicator and alarm output are optional.
Bi-directional: Direction output, opto-isolated
Empty Pipe Detection Software: defaults to zero flow.
![]() |
Magmeter Insertion Depth The meter only extends approximately 1/8th of diameter into the pipe, minimizing the potential for clogging due to debris. |

| Flow Range (GPM) | ||
| Pipe Size | Min. Flow | Max. Flow |
| 2 | 2.1 | 209 |
| 3 | 4.6 | 461 |
| 4 | 7.9 | 794 |
| 6 | 18 | 1,800 |
| 8 | 31.2 | 3,120 |
| 10 | 49.2 | 4,920 |
| 12 | 70 | 6,980 |
| 16 | 110 | 11,020 |
| 24 | 251 | 25,060 |
|
|
Pipe K Factors (Pulses per Gallon) for Various Pipe Sizes | ||||||||||||||||
|
|
2" | 3" | 4" | 6" | 8" | 10" | 12" | 14" | 16" | 18" | 20" | 22" | 24" | 30" | 36" | 42" | 48" |
| Sch. 40 PVC/Steel | 143.4 | 65.01 | 37.80 | 16.66 | 9.62 | 6.10 | 4.30 | 3.56 | 2.72 | 2.152 | 1.731 | - | 1.197 | - | 0.515 | - | - |
| Sch. 80 PVC/Steel | 163.0 | 72.86 | 41.86 | 18.46 | 10.54 | 6.70 | 4.74 | 3.92 | 2.99 | 2.357 | 1.904 | 1.571 | 1.318 | 0.722 | 0.497 | - | - |
| Stainless Steel (10S) | 131.7 | 57.66 | 33.76 | 16.20 | 8.83 | 5.64 | 3.99 | 3.30 | 2.51 | 1.973 | 1.601 | 1.318 | 1.110 | 0.710 | - | - | - |
| Stainless Steel (40S) | 143.4 | 65.01 | 37.80 | 16.66 | 9.62 | 6.10 | 4.19 | 3.49 | 2.63 | 2.059 | 1.654 | 1.357 | 1.134 | 0.716 | 0.493 | 0.360 | 0.263 |
| Type L Copper Tubing | 155.5 | 70.65 | 40.18 | 17.94 | 10.27 | 6.61 | 4.58 | - | - | - | - | - | - | - | - | - | - |
| Type. K Copper Tubing | 159.7 | 72.51 | 41.19 | 18.59 | 10.66 | 6.86 | 4.79 | - | - | - | - | - | - | - | - | - | - |
| Copper Pipe | 144.3 | 65.35 | 38.80 | 16.33 | 9.58 | 6.13 | - | - | - | - | - | - | - | - | - | - | - |
| Class 52 Duct. Iron | - | - | 34.41 | 15.54 | 8.71 | 5.65 | 3.95 | 2.91 | 2.22 | 1.756 | 1.422 | - | 0.987 | 0.635 | - | - | - |
These modules mount directly on the EX series electrical enclosure or remote mount on
a wall or in a panel
FT420: Indicating transmitter features rate and total display and 4-20 mA output. It also provides scaled pulse output for solenoid driven pump pacing, a pulse pass through for use with a PLC, and a programmable flow rate setpoint. Power: 4-20 mA Loop Powered, 12-32 VDC A055: 4-20 mA output module is easily scaled using rotary switches to enter the desired top end of range. Power: 12-36 VDC FS30: Converts mag flow sensor to a flow switch. Setting is easy using rotary switches inside the housing. An indicator shows switch status. Power: 12-36 VDC |
![]() FT420
A055
|
| PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS | |
| Model | Material |
| EX101 | B = Brass |
| EX201 | S = 316 SS |
| EX115 | |
| EX215 | |
| Options | |
| - = Pulse Output (standard) | |
| FT420M = FT420 (mount in transmitter enclosure) | |
| *FT420W = FT420 (remote wall mounting) | |
| A055M = A055 (mount in transmitter enclosure) | |
| *A055W = A055 (remote wall mounting) | |
| FS30M = FS30 (mount in transmitter enclosure) | |
| *FS30W = FS30 (remote wall mounting) | |
| *Supplied with brackets for wall mounting | |