Clark Solutions

IP 100/200 Series Insertion Liquid Flow Transmitters

Flow rates from 1.9 GPM to 170,000 GPM,
3" to 48" Pipe Sizes

DESCRIPTION

Ruby bearings and a non-drag pick-off give these adjustable insertion flow sensors the widest flow range of any of the paddlewheel types. A sensor detects the passage of miniature magnets in the six rotor blades. The resulting squarewave signal can be sent for hundreds of feet without a transmitter, over unshielded cable. This signal can be connected directly to many PLC's and other controls without any additional electronics. Installation fittings are standard 1- 1/2" or 2" NPT. A depth adjustment system allows two basic sizes to cover pipe sizes from 3" to 48".

A modular system of electronics can be attached directly to the flow sensor or remotely mounted. The FT415/420 provides full indication of rate and total, plus 4-20 mA output. The AO55 provides a 4-20 mA output, and the PD10 has a programmable pulse output for pump pacing.

The installation fitting of the EX sensor is standard male NPT, and can be directly threaded into ordinary saddles or threaded weld fittings. The IP115 and 215 include an isolation valve, allowing hot-tap installation, or installation and removal under pressure. The standard isolation valve is Bronze, but a 316 Stainless Steel valve is available as an option if needed.

SPECIFICATIONS

Sensor: Hall effect Sensor, 12 VDC current sinking pulse

Materials:
   Sensor Body: Brass, 316 SS, PVC
   Rotor: PVDF
   Shaft: Nickel-bound tungsten carbide or zirconia,
   Bearings: Ruby
   Range: 0.3 - 30 FPS (0.1 - 9 M/s)
   Accuracy: ± 1-1/2% FS

Maximum Pressure:
   PVC: 150 psi @75° F (10 bar)F
   Brass & SS: 200 PSI (14 bar)
   316 SS: 250 PSI (17 bar)

Insertion Force: 0.44 X pressure in pipe.

Pipe Size:
   IP 101/115: 3"- 10" (50-250mm)
   IP 201/215: 10"- 48" (250-1200mm)

Maximum Temperature:
   PVC: 130°F (55° C) @ 0 psi
   Brass & SS: 200°F (93° C)

Fitting Size: PVC, 2" NPT; Brass & SS, 1-1/2" NPT
Power: 5-24 VDC,1.5mA
Nominal K-factor: 11 Hz/ FPS (3.6 Hz/M/s)
Cable: #22 AWG 3-con, 18'(6m)
Maximum Cable Run: 2,000' (650m)

FEATURES

 

IP101/IP201

Features

 

IP 115/IP215

Features

 

Features

Flow Range (GPM)
Pipe Size Min. Flow Max. Flow
3 7 700
4 12 1,100
6 30 2,500
8 50 4,500
10 75 7,000
12 100 10,000
16 175 16,000
24 400 35,000

 

IP101-201/115-215 Pipe K Factors (Pulses per Gallon) for Various Pipe Sizes

 

3" 4" 5" 6" 8" 10" 12" 16" 24" 30" 36" 38" 42"
Sch. 40 PVC/Steel 28.92 16.79 10.69 7.40 4.27 2.14 1.51 0.960 0.420 0.250 0.180 0.160 0.135
Sch. 80 PVC/Steel 32.37 18.59 11.75 8.20 4.68 2.35 1.66 1.050 - - - - -
Stainless Steel (10S) 25.61 15.00 9.71 6.74 3.92 1.98 1.40 - - - - - -
Stainless Steel (40S) 28.92 16.79 10.51 7.40 4.27 2.14 1.49 - - - - - -
Stainless Steel (80S) 32.37 18.59 11.75 8.20 4.68 2.26 - - - - - - -
Type. K Copper Tubing 32.21 18.12 11.79 8.26 4.73 - - - - - - - -
Type L Copper Tubing 31.39 17.85 11.46 7.97 - - - - - - - - -
Copper Pipe 29.03 17.01 10.62 7.26 4.25 - - - - - - - -
Class 52 Duct. Iron 25.93 15.28 - 6.90 3.86 1.99 1.39 0.780 - - - - -

OPTIONAL OUTPUT MODULES

These modules mount directly in a meter enclosure (supplied installed) or remote mount on
a wall or in a panel.

FT415/420: FT420 indicating transmitter features rate and
total display and 4-20 mA output. It also provides scaled pulse
output for solenoid driven pump pacing, a pulse pass through
for use with a PLC, and a programmable flow rate setpoint.
Model FT415 is a battery powered indicating transmitter similar
to FT420 except it does not have a 4-20 mA output.

Power: 4-20 mA Loop Powered, 12-32 VDC
Rate Display: 6-digit autorange, 1/2” character height.
Pulse Output: 0.1 sec.open collector pulse (scaled);
   high or low alarm; sensor pulse (unscaled)
Input: pulse frequency, +5 VDC K
Factor Range: 0.050-999999.9
Pulse Output Range: 0.1-200,000 units/pulse
Flow Alarm Output Range: 0.1-999999.99
Enclosure: NEMA 4X die-cast aluminum.

A055: 4-20 mA output module is easily scaled using rotary switches to enter the desired top end of range.

Power: 12-36 VDC
Temperature: 32º-130ºF (0º to 55ºC)
Input: open-collector, solid-state
Min Frequency: 10 Hz (@20 mA)
Max. Frequency: 999.9 Hz
Output: Proportional 4-20 mA
Frequency Setting: 4 Rotary DIP switches
Input Averaging: 2-16 seconds, switch selectable
Response Time: 2-60 seconds 90% full scale.

PD10: Output module is easily scaled using rotary switches to enter the desired number of pulses from paddle sensor to equal one pulse output to pump.

Power: 6-18 VDC
Divider: 1-999
Temperature: 32º-130ºF (0º to 55ºC)
Max. Frequency: 350 Hz (pulses/second)
Output: Open Collector transistor, 100 mS duration.

FT420- Meter Mount

FT420- Meter Mount


FT420- Wall Mount

FT420- Wall Mount

A055 Meter Mount

A055 Meter Mount

PD10 OUTPUT MODULE

PD10

ORDERING INFORMATION

ORDER NUMBER EXAMPLE: IP115-SA055

PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS
Model Material Output Options
IP101 Models IP101/202 B= Brass -= Pulse Output (standard)  01= Ceramic Shaft
IP201  S= 316 SS FT415 or FT420M= FT415 or FT420 (mounted in meter enclosure)  03= Bi-directional output (2 outputs) 
IP115 P= PVC *FT415W orFT420W= FT 415 orFT420 (remote wall mounting)  06= LMI connector 
IP215 Models IP115/215 B= Brass Unit/Bronze Ball Valve A055M= A055 (mounted in meter enclosure)  08= Stainless Valve Assembly (Model IP115/215)
   S= 316 SS Unit/Bronze Ball Valve  *A055W= A055 (remote wall mounting) 40= Submersible (consult Clark)
P= PVC Unit/PVC Gate Valve PD10M= PD10 (mounted in meter enclosure) 60= Viton O-rings
  PD10W= PD10 (remote wall mounting, requires Option 07) E= EPDM O-ring
  07= Seametrics connector (to connect wall mount PD10 to meter)
*Supplied with brackets for wall mounting

For assistance call 978-568-3400