The IP80 Series are impeller-type insertion meters designed for use in pipe sizes 1/2" to 8". High-quality jewel bearings and nickel-bound tungsten carbide shaft are used for maximum life and extremely low friction. Bodies are machined from solid rod for maximum precision. Low-flow performance is superior. The rotation of the rotor is detected by a zero-drag Hall-effect sensor. Output is a pulse-type square wave, which can be sent long distances (up to 2,000 feet) without a transmitter. This signal can be connected directly to Clark data logger and control modules, as well as PLC's, counters, and computer cards.
IP meters are ideal for chemical proportioning applications. For rate and total display, as well as pump pacing, the FT415/420 flow indicator can be mounted directly on the IP80 Series, or remotely on a wall or panel. If display is not required for pump pacing, pulse divider PD10 provides adjustable pump pacing.
The IP80 Series come with special fittings, ensuring correct depth placement in the pipe. Fittings are available in PVC, brass, and stainless steel. Sensors are available in brass, 316 stainless steel, PVC, and polypropylene. In plastic pipe 3"- 8", use an IP82 sensor, which is 1.00" longer than the IP81 to accommodate the larger fittings.
Sensor: Hall effect Sensor, 12 VDC current sinking pulse
Materials:
Sensor Body: PVC, Polypro, Brass, or 316 SS
Rotor: Kynar (PVDF)
Shaft: Nickel-bound tungsten carbide, ceramic optional
Bearings: Ruby jewel
O-ring: Buna-N, Viton® or EPDM optional
Maximum Temperature:
PVC, Polypro (See Temp. Chart):130°F (55°C) Brass,
SS: 200°F (93°C)
Maximum Pressure:
PVC & Polypro (See Temp. Chart): 175 PSI (12 bar) at 75°F
Brass: 200 PSI (14 bar)
316 SS: 250 PSI (17 bar)
Accuracy: ±1.5% F.S.
K-factor: IP80 Series meter are factory calibrated in their fittings.
The K-factor (meter factor) is indicated on the side of the fitting.
This represents the actual number of pulses per gallon the
meter produced during the factory flow
test.


| Table 1-Flow Ranges (GPM) | |||||||||
| 1/2" | 3/4" | 1" | 1-1/2" | 2" | 3" | 4" | 6" | 8" | |
| Min. | 0.28 | 0.50 | 0.80 | 1.90 | 3.10 | 6.90 | 12.00 | 27.00 | 47.00 |
| Max. | 28 | 50 | 80 | 190 | 314 | 691 | 1200 | 2700 | 4700 |
The following Tee fittings, saddle fittings and weld fittings are available for IP80 series paddle flow meters.
| Model | Material & Style | Size code for pipe size | ||||||
| 1/2" | 3/4" | 1" | 1-1/2" | 2" | 3" | 4" | ||
| MF81T-P | PVC/male stub | 050 | 075 | 100 | 150 | 200 | * | * |
| MF81TC-B | Bronze/female sweat (copper tube) | 050 | 075 | 100 | 150 | 200 | 300 | 040 |
| MF81T-B | Bronze/female thread | 050 | 075 | 100 | 150 | 200 | 300 | 040 |
| MF81T-S | 304 SS/female thread | 050 | 075 | 100 | 150 | 200 | - | - |
| MF81T-C | Carb-Steel female thread | 050 | 075 | 100 | 150 | 200 | - | - |
| *Use MF82S-P with Option-16- see Table 3 | ||||||||
| Model | Material & Style | Size code for pipe size | |||
| 3" | 4" | 6" | 8" | ||
| MF82S-P | **PVC | 300 | 400 | 600 | 800 |
| MF82S-F | Ductile Iron | 300 | 400 | 600 | 800 |
| MF82S-Y | Polypro | 300 | 400 | 600 | 800 |
| MF83S-B | Bronze | 300 | 400 | - | - |
| Option 16 | Saddle fitting installed on 16" long pipe stub (PVC only) | ||||
| **PVC saddles are supplied with Buna-N 0-rings only. For chemical service the o-ring must be removed and the saddle must be glued onto the pipe with PVC cement used as directed. | |||||
| Model | Material & Style | Size code for pipe size | |||
| 3" | 4" | 6" | 8" | ||
| MF82W-B | Bronze | 300 | 400 | 600 | 800 |
| MF82W-C | Carbon Steel | 300 | 400 | 600 | 800 |
| MF82W-S | 316 SS | 300 | 400 | 600 | 800 |
These modules mount directly in a meter enclosure (supplied installed) or remote mount on
a wall or in a panel.
FT415/420: FT420 indicating transmitter features rate and Power: 4-20 mA Loop Powered, 12-32 VDC A055: 4-20 mA output module is easily scaled using rotary switches to enter the desired top end of range. Power: 12-36 VDC PD10: Output module is easily scaled using rotary switches to enter the desired number of pulses from paddle sensor to equal one pulse output to pump. Power: 6-18 VDC |
![]() FT420- Meter Mount
FT420- Wall Mount
A055 Meter Mount
PD10 |
| PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS | ||||
| Model | Material | Output | Fitting | Options |
| IP81 | B = Brass | - = Pulse Output (standard) FT415 or | Select Model & Size Code From Tables 2, 3, or 4 | 01 = Ceramic Shaft |
| IP82 | S = 316 SS | FT420M = FT415 or FT420 (mounted in meter enclosure) | 06 = LMI connector | |
| P = PVC | *FT415W or FT420W = FT 415 orFT420 (remote wall mounting) | 16 = See Table 3 | ||
| Y = Polypro | A055M = A055 (mounted in meter enclosure) | 60 = Viton® O-rings | ||
| K = PVDF | *A055W = A055 (remote wall mounting) | E = EPDM O-ring | ||
| PD10M = PD10 (mounted in meter enclosure) | 07 = Seametrics connector (to connect wall mount PD10 to meter) | |||
| PD10W = PD10 (remote wall mounting) | ||||
| *Supplied with brackets for wall mounting | ||||