Get a printer friendly Acrobat™ file of the
CSLFB Manual

Clark Sonic Logo

CSLFB Liquid Ultrasonic Flow Transmitters

Loop Powered 4-20 mA Output, Flows to 400 GPM, 3/4" to 3" Pipe, Brass

DESCRIPTION

Clark Sonic ultrasonic flow transmitters are ideal for measurement of flow rates of acoustically conductive liquids, including most clean liquids and many liquids with entrained solids.

Main advantages include excellent long term stability, no pressure drop, broad fluid compatibility, high accuracy and low cost. Also, there are no moving parts.

At the heart of the transmitter is a proprietary mixed signal ASIC which allows sophisticated timing, control and transducer drive circuitry to be combined on a single integrated circuit. The ASIC uses a special algorithm that is an improvement upon the standard single-path measurement technique. Using the "sing around" method, the ultrasonic transducer alternates between transmitting and receiving to measure differences in flight time between upstream and downstream transmissions. A sound pulse is transmitted from an upstream transducer towards a downstream transducer like a traditional time-of-flight measurement. However, the received sound pulse then triggers a second downstream transmission that then triggers a third and so on for a specific number of cycles. This process is repeated in the upstream direction.

Because it takes an average flight time over multiple cycles to compute the 
difference in flight times, the approach yields a significant improvement in timing 
accuracy when compared with the time-of-flight difference of a single sound pulse in 
each direction. This algorithm, combined with the pico-second timing resolution of the 
ASIC, provides the precise time measurement capability necessary for compact, small 
diameter ultrasonic meters.
The output of the transmitter is unaffected by changes in fluid temperature, density 
and viscosity as the flow calculation is independent of the speed of sound.
Wetted materials include ULTEM® encapsulated ultrasonic transducers with a choice 
of elastomer seals and Brass body material.

SPECIFICATIONS
GENERAL

Flow Range: Bi-directional, field selectable per "Standard Models" table
Accuracy: ±.75% of full scale
Operating Temperature: -40 to 190°F (-40 to 87.8°C)
Response Time: User Selectable, 2 or 10 seconds
Viscosity Range: 0.2 to 150 cSt (0.2 to 150 mPas)
Liquid Density: 30.6 to 74.9 lb/cu.ft. (490 to 1200 kg/m3)
Max. Working Pressure: 250 PSI (17.2 bars)
Pipe Sizes: 3/4", 1", 1 1/2", 2", 3"
Pipe Connections:
    Sizes 3/4" to 2"- Female NPT, BSP
    Size 3": ASME 150 or DIN 16 Flange
Electrical Enclosure: Integral to Body casting with gasketed cover; One 1/2" 
    NPT conduit connection (plugged when model ordered with metric threads) 
    and one M16 x 1.5 connection (plugged when model ordered with NPT threads)
Electrical Connections: Screw terminal connections on PC board
Enclosure Rating: NEMA 4 (IP 65)
Power: 18 to 36 VDC

WETTED MATERIALS

Ultrasonic Transducers: ULTEM® Encapsulated
Seals: EPDM, Buna-N, Neoprene, FKM, or other
Body Material: Brass (UNS C83600)

OUTPUT

Analog: 2-wire, 4-20 mA output; Output is 4 mA from zero to min. flow 
    (see Standard Model table)
Error Detection: An optically isolated sink output is activated under 
   certain detectable fault conditions, such as transducer failure or 
   overly noisy output due to flow stream anomalies, as might be seen 
   due to excessive bubble entrainment. The optional Fault output is 
   an optically isolated NPN transistor capable of sinking up to 10 mA 
   from a voltage source of no more than 48 VDC.
Direction of Flow: Optional output to indicate direction of flow is 
   available. Activation or deactivation of an optically isolated 10 mA 
   sink output indicates flow direction. Error detection is not available 
   when this option is ordered.
Optional Temperature Sensor: 3 wire RTD, 100 Ohm, Platinum, 0.06% accuracy. 
	Built in to transducer shell for monitoring process temperature. 
	Optional 8 pin electrical connector standardly recommended with this option.

Optional NEMA 4 four or eight-pin receptacles installed in transmitter conduit connection and factory wired along with mating circular connectors simplify field installation.

Graph
Pipe Sizes
Size/Connection A B C D E
Inches mm Inches mm Inches mm Inches mm Inches mm
3/4" & 1" 9.20 234 1.62 41.10 2.06 52.30 6.40 163 2.40 61.00
1-1/2" & 2" 9.88 251 2.75 69.90 2.51 63.80 6.40 163 2.40 61.00


Pipe Flange
Size/Connection A B C D E
Inches mm Inches mm Inches mm Inches mm Inches mm
3" ASME 150 11.00 - Ø 7.50 - 3.16 - 6.50 - 2.50 -

80 mm DIN 16

- 280 - 190 - 84.00 - 165 - 63.50

STANDARD MODELS

Model Pipe Size/Thread Size *Field Selectable Full Scale Ranges (GPM) *Field Selectable Full Scale Ranges (LPM)
  Min. Max. Min. Max.
CSLFB34 3/4" NPT or BSP L 0.23 15 0.90 60
H 0.38 25 1.50 100
CSLFB10 1.0" NPT or BSP L 0.45 30 1.70 115
H 0.75 50 3.00 200
CSLFB15 1.50" NPT or BSP L 0.60 40 2.30 150
H 1.20 80 4.50 300
CSLFB20 2.0" NPT or BSP L 0.90 60 3.40 225
H 1.80 120 6.80 455
CSLFB30 3" ASME Class 150 Flange 80 mm DIN Class 150 Flange L 3.00 200 11.00 750
H 6.00 400 23.00 1500
*Other F.S. ranges can be specified

DP/DS PANEL METER/DISPLAY OPTION

Digital panel meter installed on transmitter Power Supply: Loop Powered Display: 4-1/2 Digit LED, 0.6" Case: NEMA 4X Versions: DP Option: Displays 0-100% F.S DS Option: Scaled to customer requirement

 

       Panel Meter/Display option

      Four or eight pin receptacle
      connector recommended.

 

ORDERING INFORMATION ORDER NUMBER (ABCD) Example: CSLFB10NPTGB
FOR YOUR CONVENIENCE, THESE ITEMS ARE AVAILABLE ONLINE OR PLEASE CALL 1-800-253-2497 TO ORDER
A B C D
Model Pipe Thread Units of Measure Transducer Seal
3/4" to 2" 3"
CSLFB34 NPT= Female NPT ASME= ASME Class 150 Flange G= Gallons Per Minute (U.S.) E= EPDM
CSLFB10 B = Buna-N
CSLFB15 BSP=Female British Standard Pipe (G) DIN = DIN Class 16 Flange L = Liters Per Minute N= Neoprene®
CSLFB20 V= FKM
CSLFB30
 
Options
-= None
DF= Direction of flow output option, call factory at 1-800-253-2497 to order.
R=100 OhmPlatinum RTD
DP=Display % F.S
DS=Display in Engineering Units- specify
 
Transmitter Connector Option
-= 1/2" NPT
4R= 4-Pin Male Circular Receptacle
8R= 8-Pin Male Circular Receptacle
4C= 4-Pin Female Circular Connector
8C= 8-Pin Female Circular Connector
 
*For non-listed ranges specify model followed by full span value
Example: CSLFB15-50G = 50 GPM at 20 mA or CSLFB15-200L=200LPM @ 20 mA

Qty:

Show Discount Schedule


ULTEM® is a registered trademark of The General Electric Company Neoprene® is a registered trademark of DuPont Dow Clark reserves the right to make design changes without prior notice.
INSTRUMENTATION > FLOW > CSLFB Liquid Ultrasonic Flow Transmitters