CSLFC Liquid Ultrasonic Flow Transmitters

Loop Powered 4-20 mA Output, Flows to 3000 GPM, 4" to 10" Pipe, Carbon Steel

DESCRIPTION

ClarkSonic Ultrasonic Flowmeters are ideal for measurement of flow rates of acoustically conductive liquids including most clean liquids and many liquids with entrained solids.

Main advantages include excellent long term stability, no pressure drop, broad fluid compatibility, high accuracy and low cost. Also, there are no moving parts.

At the heart of the transmitter is a proprietary 
mixed signal ASIC which allows sophisticated 
timing, control and transducer drive circuitry 
to be combined on a single integrated circuit. 
The ASIC uses a special algorithm that is an improvement upon 
the standard single-path measurement technique. Using the 
"sing around" method, the ultrasonic transducer alternates between 
transmitting and receiving to measure differences in flight time between 
upstream and downstream transmissions. A sound pulse is transmitted from 
an upstream transducer towards a downstream transducer like a traditional 
time-of-flight measurement.  However, the received sound pulse then triggers 
a second downstream transmission that then triggers a third and so on for a 
specific number of cycles. This process is repeated in the upstream direction.
Because it takes an average flight time over multiple cycles to compute the 
difference in flight times, the approach yields a significant improvement in timing 
accuracy when compared with the time-of -flight difference of a single sound pulse 
in each direction. This algorithm, combined with the pico-second timing resolution 
of the ASIC, provides the precise time measurement capability necessary for compact, 
small diameter ultrasonic meters.
The output of the transmitter is unaffected by changes in fluid temperature, density 
and viscosity as the flow calculation is independent of the speed of sound.
Wetted materials include ULTEM® encapsulated ultrasonic transducers with a choice 
of elastomer seals and epoxy coated carbon steel body material.

SPECIFICATIONS
GENERAL

Flow Range: Bi-directional, field selectable per "Standard Models" table
Accuracy: ±0.75% of full scale
Operating Temperature: -40 to 180°F
Response Time: User selectable, 2 or 10 seconds
Viscosity Range: 0.2 to 150 cSt (0.2 to 150 mPas)
Liquid Density: 30.6 to 74.9 lb/cu.ft. (490 to 1200 kg/m3)
Max. Working Pressure: 200 PSI
Pipe Sizes: 4", 6", 8", 10"
Pipe Connections: ASME class 150 flange
Electrical Enclosure: Integral to Body casting with gasketed cover; One 1/2" 
    NPT conduit connection (plugged when model ordered with metric threads) 
    and one M16 x 1.5 connection (plugged when model ordered with NPT threads)
Electrical Connections: Screw terminal connections on PC board
Enclosure Rating: NEMA 4 (IP 65)
Power: 18 to 36 VDC

WETTED MATERIALS

Ultrasonic Transducers: ULTEM® Encapsulated
Seals: EPDM, Buna-N, Neoprene, FKM, or other
Body Material: Schedule 40, epoxy coated, carbon steel pipe

OUTPUT

Analog: 2-wire, 4-20 mA output; Output is 4 mA from zero to min. flow 
    (see Standard Model table)
Error Detection: An optically isolated 10 mA (max. 48V no load voltage) sink 
    output is activated under certain detectable fault conditions, such as transducer 
    failure or overly noisy output due to flow stream anomalies, as might be seen due 
    to excessive bubble entrainment.
Direction of Flow: Optional output to indicate direction of flow is available. 
    Activation or deactivation of an optically isolated 10 mA (max. 48V no load voltage) 
    sink output indicates flow direction. Error detection is not available when this 
    option is ordered.
 

Graph
Pipe Sizes
Pipe Size Dimensions (Inches)
A B C D E F Bolt Circle Diameter Number of Holes
4" 13.00 9.00 4.00 6.54 2.62 0.75 7.50 8
6" 16.00 11.00 5.09 6.54 2.62 0.88 9.50 8
8" 18.00 13.50 6.11 6.54 2.62 0.88 11.75 8
10" 22.00 16.00 7.18 6.54 2.62 1.00 14.25 12


STANDARD MODELS

Model Pipe Size *Field Selectable Full Scale Ranges (GPM) Min. Max *Field Selectable Full Scale Ranges (LPM) Min. Max
CSLFC4 4" L 6.25 500 25 2000
H 12.5 1000 50 4000
CSLFC6 6" L 12.5 1000 50 4000
H 25 2000 94 7500
CSLFC8 8" L 25 2000 94 7500
H 50 4000 188 15000
CSLFC10 10"   37.5 3000 138 11500
*Other F.S. ranges can be specified


ORDERING INFORMATION ORDER NUMBER (ABCD) Example: CSLFC10GB
PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS
A B C
Model Units of Measure Transducer Seal
CSLFC4 G= Gallons Per Minute (U.S.) E = EPDM
CSLFC6 L= Liters Per Minute B = Buna-N
CSLFC8   N= Neoprene®
CSLFC10 V= FKM
 
Options
DF= Direction of flow output option
 
*For non-listed ranges specify model followed by full span value
Example: CSLFC4-300G = 300 GPM at 20 mA or CSLFC4-750L=750LPM @ 20 mA