Clark Solutions
100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches
Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650°F
(Page 2 of 4)

|
|
|
PRESSURE MODEL H100
| Range/Material Code |
Adjustable Set Point Range |
Deadband |
*Over Range Pressure |
**Proof Pressure |
| psi |
bar |
psi |
bar |
psi |
bar |
psi |
bar |
|
1.5" sanitary welded 316L stainless steel diaphragm and pressure connection. Mates with Tri-Clamp fitting systems
|
|
565
|
5 to 30
|
0.3 to 2.1
|
1 to 5
|
0.07 to 0.3
|
1000
|
68.9
|
1500
|
103.4
|
|
566
|
10 to 100
|
0.7 to 6.9
|
1 to 12
|
0.07 to 0.8
|
1000
|
68.9
|
1500
|
103.4
|
|
567
|
15 to 300
|
1.0 to 20.7
|
3 to 22
|
0.21 to 1.5
|
1000
|
68.9
|
1500
|
103.4
|
|
Buna-N diaphragm and O-Ring with 1/4" NPT (female) nickel-plated brass pressure connection; Option M540 Viton® diaphragm & O-Ring available for code 704-705
|
|
701
|
1.5 to 30
|
0.1 to 2
|
1 to 2
|
0.07 to 0.14
|
500
|
34.5
|
600
|
41.4
|
|
702
|
3 to 100
|
0.2 to 6.9
|
1 to 4
|
0.07 to 0.28
|
500
|
34.5
|
600
|
41.4
|
|
703
|
9 to 300
|
0.7 to 20.7
|
1 to 5
|
0.07 to 0.34
|
500
|
34.5
|
600
|
41.4
|
|
704
|
15 to 500
|
1.0 to 34.5
|
2 to 8
|
0.14 to 0.55
|
1500
|
103.4
|
2500
|
172.4
|
|
705
|
30 to 1000
|
2.1 to 69
|
3 to 20
|
0.21 to 1.38
|
1500
|
103.4
|
2500
|
172.4
|
|
706
|
100 to 1700
|
6.9 to 117
|
10 to 30
|
0.07 to 2.07
|
2000
|
137.9
|
2500
|
172.4
|
|
316L stainless steel diaphragm (optional Hastelloy®C, Monel® or Tantalum); Viton® GLT O-Ring (optional Kalrez®, Silicone, Ethylene Propylene, or Aflas®); 316 stainless steel 1/2" NPT (female) pressure connection (optional Hastelloy®B or C, or Monel®), large 0.72" orifice for clean-out purposes. Models 188 & 189 have a 316L stainless steel 1/2" NPT (female) pressure connection
|
|
183
|
1 to 20
|
0.07 to 1.4
|
0.3 to 2.5
|
0.021 to 0.17
|
500
|
34.5
|
1000
|
68.9
|
|
184
|
2 to 50
|
0.14 to 3.4
|
0.3 to 3
|
0.021 to 0.2
|
500
|
34.5
|
1000
|
68.9
|
|
185
|
4 to 100
|
0.3 to 6.9
|
0.5 to 6
|
0.03 to 0.4
|
500
|
34.5
|
1000
|
68.9
|
|
186
|
8 to 200
|
0.6 to 13.8
|
1 to 11
|
0.07 to 0.8
|
500
|
34.5
|
1000
|
68.9
|
|
188
|
50 to 1000
|
3.45 to 68.9
|
25 to 125
|
1.7 to 8.6
|
2000
|
137.9
|
7000
|
482.6
|
|
189
|
250 to 3500
|
17.3 to 241.3
|
50 to 300
|
3.4 to 20.7
|
4000
|
275.8
|
7000
|
482.6
|
|
|
Range/
Material Code |
Adjustable Set Point Range |
Deadband |
*Over Range Pressure |
**Proof Pressure |
| Lower 75% range |
Top 25% Range |
| psi |
bar |
psi |
bar |
psi |
bar |
psi |
bar |
psi |
bar |
| Welded stainless steel diaphragm with 1/2" NPT (female) pressure connections, large 0.072" orifice for clean-out purposes |
|
190
|
5 to 30
|
0.3 to 2.1
|
1 to 3
|
0.07 to 0.2
|
6 max
|
0.4
|
1500
|
103.4
|
2500
|
172.4
|
|
191
|
10 to 100
|
0.7 to 6.9
|
1 to 8
|
0.07 to 0.6
|
15 max
|
1.0
|
1500
|
103.4
|
2500
|
172.4
|
|
192
|
15 to 300
|
1 to 20.7
|
3 to 18
|
0.2 to 1.2
|
25 max
|
1.7
|
1500
|
103.4
|
2500
|
172.4
|
|
193
|
20 to 500
|
1.4 to 34.5
|
4 to 30
|
0.3 to 2.1
|
45 max
|
3.1
|
1500
|
103.4
|
2500
|
172.4
|
|
194
|
80 to 1700
|
5.5 to 117.2
|
5 to 120
|
0.3 to 8.3
|
150 max
|
10.3
|
2000
|
137.9
|
2500
|
172.4
|
|
Welded 316 stainless steel diaphragm with 1/2" NPT (female) pressure connection, 0.06" orifice to dampen pulsations
|
|
490
|
5 to 30
|
0.3 to 2.1
|
1 to 3
|
0.07 to 0.2
|
6 max
|
0.4
|
1500
|
103.4
|
2500
|
172.4
|
|
491
|
10 to 100
|
0.7 to 6.9
|
1 to 8
|
0.07 to 0.6
|
15 max
|
1.0
|
1500
|
103.4
|
2500
|
172.4
|
|
492
|
15 to 300
|
1 to 20.7
|
3 to 18
|
0.2 to 1.2
|
25 max
|
1.7
|
1500
|
103.4
|
2500
|
172.4
|
|
493
|
20 to 500
|
1.4 to 34.5
|
4 to 30
|
0.3 to 2.1
|
45 max
|
3.1
|
1500
|
103.4
|
2500
|
172.4
|
|
494
|
80 to 1700
|
5.5 to 117.2
|
5 to 120
|
0.3 to 8.3
|
150 max
|
10.3
|
2000
|
137.9
|
2500
|
172.4
|
|
|
|
Range/Material Code
|
Adjustable Set Point Range
|
Deadband
|
*Over Range Pressure
|
**Proof Pressure
|
|
psi
|
bar
|
psi
|
bar
|
psi
|
bar
|
psi
|
bar
|
|
316L stainless steel diaphragm (optional Hastelloy®C, Monel® or Tantalum) Viton® GLT O-Ring (optional Kalrez®, Silicone, ethylene propylene or Aflas®), 316 stainless steel 1/2" NPT (female) pressure connection (optional Hastelloy® B, or C, or Monel®), 0.06" orifice. Models 488 & 489, 316L pressure connection.
|
|
483
|
1 to 20
|
0.07 to 1.4
|
0.3 to 2.5
|
0.02 to 0.17
|
500
|
34.5
|
1000
|
68.9
|
|
484
|
2 to 50
|
0.14 to 3.4
|
0.3 to 3
|
0.02 to 0.2
|
500
|
34.5
|
1000
|
68.9
|
|
485
|
4 to 100
|
0.3 to 6.9
|
0.5 to 6
|
0.03 to 0.4
|
500
|
34.5
|
1000
|
68.9
|
|
486
|
8 to 200
|
0.6 to 13.8
|
1 to 11
|
0.07 to 0.8
|
500
|
34.5
|
1000
|
68.9
|
|
488
|
50 to 1000
|
3.4 to 68.9
|
25 to 125
|
1.7 to 8.6
|
2000
|
137.9
|
7000
|
482.6
|
|
489
|
250 to 3500
|
17.2 to 241.3
|
50 to 300
|
3.4 to 20.7
|
4000
|
275.8
|
7000
|
482.6
|
|
Phosphor bronze bellows with 1/4" NPT (female) nickel-plated brass pressure connection. Model 218 has 300 series stainless steel spring in media
|
|
218
|
30" Hg Vac to 0
|
-1 to 0
|
1 to 2" Hg
|
0.03 to 0.07
|
0
|
0
|
30
|
2.07
|
|
270
|
4 to 200
|
0.3 to 13.8
|
1 to 8
|
0.07 to 0.6
|
200
|
13.8
|
250
|
17.2
|
|
274
|
6 to 600
|
0.4 to 20.7
|
1 to 10
|
0.07 to 0.7
|
300
|
20.7
|
350
|
24.1
|
|
Welded 316L stainless steel bellows with 1/4" NPT (female) pressure connections
|
|
358
|
15 to 200
|
1 to 13.8
|
1 to 3
|
0.07 to 0.2
|
200
|
13.8
|
800
|
55.2
|
|
361
|
20 to 300
|
1.38 to 20.7
|
1 to 4
|
0.07 to 0.3
|
300
|
20.7
|
800
|
55.2
|
|
376
|
25 to 500
|
1.8 to 34.5
|
1.5 to 5
|
0.10 to 0.3
|
500
|
34.5
|
800
|
55.2
|
|
303 stainless steel piston, Buna-N O-Ring with 1/4" NPT (female) 303 stainless steel pressure connection (not recommended for gas service since drying of O-Ring seal can allow bleeding of medium into the atmosphere)
|
|
610
|
75 to 1000
|
5.2 to 68.9
|
30 to 150
|
2.07 to 10.3
|
6000
|
413.7
|
10,000
|
689.5
|
|
612
|
125 to 3000
|
8.6 to 206
|
40 to 250
|
2.76 to 17.2
|
6000
|
413.7
|
10,000
|
689.5
|
|
616
|
700 to 5000
|
48.5 to 344
|
40 to 375
|
2.76 to 25.9
|
6000
|
413.7
|
10,000
|
689.5
|
|
316 stainless steel bellows with 1/4" NPT (female) pressure connection (not recommended for gas applications or for rapid or high cycling pressure changes)
|
|
680
|
100 to 1700
|
6.9 to 117.2
|
9 to 40
|
0.6 to 2.8
|
1700
|
117.2
|
2500
|
172.4
|
|
|
DIFFERENTIAL PRESSURE MODEL H100K
|
Range/Material Code
|
Adjustable Set Point Range
|
Deadband
|
***Working Pressure
|
**Proof Pressure
|
|
"wcd/psid
|
mbar/bar
|
psi
|
mbar/bar
|
psi
|
bar
|
psi
|
bar
|
|
Kapton® diaphragm, Buna-N sealing diaphragms and epoxy coated aluminum 1/8" NPT (female) pressure connections
|
|
540
|
0.2 to 7"wcd
|
0.5 to 17.4 mbar
|
0.05 to 0.6"wc
|
0.1 to 1.5 bar
|
200
|
13.8
|
400
|
27.6
|
|
541
|
1 to 20"wcd
|
2.5 to 49.7 mbar
|
0.1 to 1.0"wc
|
0.2 to 2.5 bar
|
200
|
13.8
|
400
|
27.6
|
|
542
|
5 to 50"wcd
|
12.4 to 124.4 mbar
|
0.2 to 2.5"wc
|
0.5 to 6.2 bar
|
200
|
13.8
|
400
|
27.6
|
|
543
|
10 to 200"wcd
|
24.9 to 497.0 mbar
|
0.5 to 8"wc
|
1.2 to 19.9 bar
|
200
|
13.8
|
400
|
27.6
|
|
544
|
2 to 20 psid
|
0.1 to 1.4 bar
|
0.1 to 1.3 psi
|
6.9 to 89.6 bar
|
1200
|
82.7
|
2500
|
172.4
|
|
545
|
5 to 50 psid
|
0.3 to 3.4 bar
|
0.2 to 2.2 psi
|
0 to 0.15 bar
|
1200
|
82.7
|
2500
|
172.4
|
|
546
|
10 to 125 psid
|
0.7 to 8.6 bar
|
0.4 to 5.0 psi
|
0 to 0.34 bar
|
1200
|
82.7
|
2500
|
172.4
|
|
547
|
50 to 250 psid
|
3.4 to 17.2 bar
|
0.8 to 10 psi
|
0.1 to 0.69 bar
|
1200
|
82.7
|
2500
|
172.4
|
|
548
|
100 to 500 psid
|
6.9 to 34.5 bar
|
2.0 to 15 psi
|
0.1 to 1.03 bar
|
1200
|
82.7
|
2500
|
172.4
|
|
|
|
Application Notes: The use of metallic diaphragms where higher pressure shock or heavy cycling is expected should be avoided. Models 171-174 should not be used where system or start-up vacuum pressure might exceed 26 Hg Vac (-0.9 bar). Use of optional diaphragm materials for models 483-489 may increase deadband.
Deadband Note: Models 190-194, 490-494 are expressed as the lower 75% and top 25% of the range span because of the operating characteristics of the diaphragm sensor and switch.
*Over Range Pressure: The maximum pressure that may be applied continuously without causing damage and maintaining set point repeatability.
**Proof Pressure: The maximum pressure to which a pressure sensor may be occasionally subjected, which causes no permanent damage.The unit may require calibration (e.g.,start-up,testing).
***Working Pressure Range: The pressure range within which two opposing sensors can be safely operated and still maintain set point adjustability provided the difference in pressure between them does not exceed the designated adjustable range
|
|
|
|
|
|
For assistance call 978-568-3400
|
|
|
|
|
|
|
|
|
|