CLARK SOLUTIONS
Model 1335, 2-Way, NC & NO Solenoid Valve
3/8 to 3/4 Pipe Size, Piloted, Combined & Direct Acting Solenoid
DESCRIPTION
Model 1335 two-way normally closed and normally open solenoid valves are available in forged brass or 316 stainless steel bodies. A variety of seal and seat materials including Acrylo-Nitrile, Neoprene®, Ethylpropylene, and Viton® satisfy many general industry applications.
Options include weather proof coils & housing, manual override and energized coil indicator light.
SPECIFICATIONS
GENERAL
Operation: Normally closed or normally open
Valve Body Materials: Forged brass, investment
cast AISI316 stainless steel
Diaphragm: Metal core with choice of seat
material
Valve Seats: Acrylo-Nitrile, Neoprene®,
Ethylpropylene, Viton®
Valve Life: > 1,000,000 cycles, field rebuild kits
available
Connections: BSP or NPT
Operating Voltage - 12VDC, 24VDC/VAC,
120VAC, 60Hz
Standard Solenoid Housing: Encapsulated coil,
DIN 43650 connection (PG-9)
Optional Weather Proof Solenoid Housing: NEMA
4, IP65
Power Consumption:
Class F coil to 80ºC: 60 Hz, 13 W; DC,19 W
Options: Manual operation, energized coil
indicator light
|
|
|
|
 |
|
|
|
| Table 1 |
| Wetted Materials |
| Body |
Plunger |
Plunger Tower |
Springs |
Diaphragm |
Inner-Diaph. Material |
Piston |
| Brass |
AISI 430F |
304L or 305 SS |
Copper |
See Table 2 |
- |
AISI 304 |
| AISI 316 |
AISI 430F |
304L or 305 SS |
Silver & 302 SS |
See Table 2 |
AISI 316 |
AISI 316 |
|
|
|
|
| Table 2 |
| Seat Material |
Acrylo Nitrile |
Neoprene® |
Ethyl-propylene |
Viton® |
| Maximum Temperature |
+80ºC |
+80ºC |
+150ºC |
+150ºC |
| Uses |
Water, air, light oils, kerosene. Low and medium vacuum. |
Oxygen, alcohol, argon, other non-corrosive light gases and liquids. Freon 12. |
Water steam, hot water, acetone. |
Benzene, naphtha, aromatics, etc.. Hot gases. High vacuum. |
|
|
 |
|
|
| File LR87427 2M - LR108921-1 |
|
|
 |
|
|
| File MH16855 Vol. 2 Sec. 2 |
|
|
|
| Connection (NPT or BSP) |
Orifice Dia. (mm) |
Cv Coef. (GPM) |
Kv Coef. (m3/h) |
Weight (kg) |
| Brass Body, Pilot Operated, Normally Closed: Minimum Differential, 0.1 Bar; Maximum Differential Pressure, 10.0 Bar |
| 3/8" |
14 |
2.75 |
2.35 |
0.76 |
| 1/2" |
14 |
3.10 |
2.65 |
0.76 |
| 3/4" |
18 |
5.03 |
4.30 |
0.98 |
| Brass Body, Combined Acting, Normally Closed: Minimum Differential, 0 Bar; Maximum Differential Pressure, 7.0 Bar |
| 3/8" |
14 |
2.75 |
2.35 |
0.76 |
| 1/2" |
14 |
3.10 |
2.65 |
0.76 |
| 3/4" |
18 |
5.03 |
4.30 |
0.98 |
| Brass Body, Pilot Operated, Normally Open: Minimum Differential, 0.1 Bar; Maximum Differential Pressure, 10.0 Bar |
| 3/8" |
14 |
2.75 |
2.35 |
0.76 |
| 1/2" |
14 |
3.10 |
2.65 |
0.76 |
| 3/4" |
18 |
5.03 |
4.30 |
0.98 |
|
|
|
|
 |
|
DIMENSIONS MM |
|
|
A
NPT or BSP |
B
N.C. |
B
N.O. |
C |
D |
E |
F |
| 3/4 |
80 |
88 |
15 |
51 |
60 |
53 |
| 1 |
| 1, 1/2 |
82 |
90 |
17 |
58 |
72 |
55 |
|
|
|
FUNCTION |
|
|
| Piloted valves use the fluid pressure to assist in opening and closing the valve, allowing the valve to operate against higher pressures than a direct acting valve.
When the pilot valve is closed, the pressure builds up via a small passage from the upstream side of the valve piston/seat. The valve seat is also acted on by a spring.
When the pilot valve opens, a passage that bypasses the valve piston/seat and connects downstream of the piston/seat is opened, relieving pressure from the top of the valve piston/seat. The inlet fluid pressure lifts up the piston to open the valve.
|
|
|
 |
|
Flow Calculation, Liquids:
Q= Flow Rate, GPM (U.S.A.)
Cv= Valve Flow Coefficient
DP= Valve Pressure Drop, PSID
G= Specific Gravity of Liquid (= 1.0 for Water)
|
|
|
|
 |
|
 |
|
|
|
Standard Coil and DIN43650 Connector |
|
Option YC Weather Proof Housing with 1/2 NPT Threaded Conduit Connector |
|
|
|
ORDERING INFORMATION
SELECT ITEM FROM EACH COLUMN IN CHART BELOW
EXAMPLE:1335BN3AT12DC |
|
|
| FOR YOUR CONVENIENCE, THESE ITEMS ARE AVAILABLE ONLINE |
| Model |
Body Material |
Seat & Seal Material |
Pipe Connection |
Configuration |
Connection Threads |
Voltage |
| 1335 |
B= Brass |
A= Acrylo-Nitrile |
3= 3/8 |
- = Pilot operated, Normally Closed |
T= NPT |
12DC= 12 VDC |
| V= Viton |
4= 1/2 |
120AC= 120 VAC, 60 Hz |
| |
6= 3/4 |
24DC= 24VDC |
| |
| Options |
| Prefix YC= Weather Proof Housing (1/2" NPT Thread) |
| Bold Order Combinations Typically Ship From Stock |
|
|
|
Show Discount Schedule
|
|
|
|
| OR PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS |
| Model |
Body Material |
Seat & Seal Material |
Pipe Connection |
Configuration |
Connection Threads |
Voltage |
| 1335 |
B= Brass |
A= Acrylo-Nitrile |
3= 3/8 |
- = Pilot operated, Normally Closed |
T= NPT |
12DC= 12 VDC |
| I= 316 SS |
V= Viton |
4= 1/2 |
A = Combined Acting, Normally Closed |
- = BSP |
120AC= 120 VAC, 60 Hz |
| |
N= Neoprene |
6= 3/4 |
INA = Pilot operated, Normally Open |
|
24DC= 24VDC |
| E= Ethylpropylene |
|
|
24AC= 24 VAC, 60 Hz |
| |
| Options |
| Prefix YC= Weather Proof Housing (1/2" NPT Thread) |
| Suffix M= Manual Operation |
| Coil Indicator Light= Consult Factory |
| Bold Order Combinations Typically Ship From Stock |
|
|
|
INSTALLATION RECOMMENDATIONS
Place a strainer with a porosity < 100µ upstream of valve (see Clark Solutions Model 1359 Y Strainer).
Install valve in any position, preferably on a horizontal pipeline with coil up.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|