Model1335_2-Way Valve

CLARK SOLUTIONS
Model 1335, 2-Way, NC & NO Solenoid Valve
3/8 to 3/4” Pipe Size, Piloted, Combined & Direct Acting Solenoid

DESCRIPTION
Model 1335 two-way normally closed and normally open solenoid valves are available in forged brass or 316 stainless steel bodies. A variety of seal and seat materials including Acrylo-Nitrile, Neoprene®, Ethylpropylene, and Viton® satisfy many general industry applications.

Options include weather proof coils & housing, manual override and energized coil indicator light.

SPECIFICATIONS
GENERAL
Operation: Normally closed or normally open
Valve Body Materials: Forged brass, investment
       cast AISI316 stainless steel
Diaphragm: Metal core with choice of seat
       material
Valve Seats: Acrylo-Nitrile, Neoprene®,
       Ethylpropylene, Viton®
Valve Life: > 1,000,000 cycles, field rebuild kits
       available
Connections: BSP or NPT
Operating Voltage - 12VDC, 24VDC/VAC,
       120VAC, 60Hz
Standard Solenoid Housing: Encapsulated coil,
       DIN 43650 connection (PG-9)
Optional Weather Proof Solenoid Housing: NEMA
       4, IP65
Power Consumption:
    Class F coil to 80ºC: 60 Hz, 13 W; DC,19 W
Options: Manual operation, energized coil
       indicator light

Table 1
Wetted Materials
Body Plunger Plunger Tower Springs Diaphragm Inner-Diaph. Material Piston
Brass AISI 430F 304L or 305 SS Copper See Table 2 - AISI 304
AISI 316 AISI 430F 304L or 305 SS Silver & 302 SS See Table 2 AISI 316 AISI 316
Table 2
Seat Material Acrylo Nitrile Neoprene® Ethyl-propylene Viton®
Maximum Temperature +80ºC +80ºC +150ºC +150ºC
Uses Water, air, light oils, kerosene. Low and medium vacuum. Oxygen, alcohol, argon, other non-corrosive light gases and liquids. Freon 12. Water steam, hot water, acetone. Benzene, naphtha, aromatics, etc.. Hot gases. High vacuum.
File LR87427 2M - LR108921-1
File MH16855 Vol. 2 Sec. 2
Connection (NPT or BSP) Orifice Dia. (mm) Cv Coef. (GPM) Kv Coef. (m3/h) Weight (kg)
Brass Body, Direct Acting, Normally Closed: Minimum Differential, 0 Bar; Maximum Differential Pressure, 0.1 Bar
3/8" 14 2.75 2.35 0.76
1/2" 14 3.10 2.65 0.76
3/4" 18 5.03 4.30 0.98
Brass Body, Pilot Operated, Normally Closed: Minimum Differential, 0.1 Bar; Maximum Differential Pressure, 10.0 Bar
3/8" 14 2.75 2.35 0.76
1/2" 14 3.10 2.65 0.76
3/4" 18 5.03 4.30 0.98
Brass Body, Combined Acting, Normally Closed: Minimum Differential, 0 Bar; Maximum Differential Pressure, 7.0 Bar
3/8" 14 2.75 2.35 0.76
1/2" 14 3.10 2.65 0.76
3/4" 18 5.03 4.30 0.98
Brass Body, Pilot Operated, Normally Open: Minimum Differential, 0.1 Bar; Maximum Differential Pressure, 10.0 Bar
3/8" 14 2.75 2.35 0.76
1/2" 14 3.10 2.65 0.76
3/4" 18 5.03 4.30 0.98
DIMENSIONS MM
A
NPT or BSP
B
N.C.
B
N.O.
C D E F
3/4” 80 88 15 51 60 53
1”
1, 1/2” 82 90 17 58 72 55
FUNCTION
Direct acting valves rely on the force applied by the solenoid or spring to change the valve state.

Piloted valves use the fluid pressure to assist in opening and closing the valve, allowing the valve to operate against higher pressures than a direct acting valve.

When the pilot valve is closed, the pressure builds up via a small passage from the upstream side of the valve piston/seat. The valve seat is also acted on by a spring.

When the pilot valve opens, a passage that bypasses the valve piston/seat and connects downstream of the piston/seat is opened, relieving pressure from the top of the valve piston/seat. The inlet fluid pressure lifts up the piston to open the valve.

Flow Calculation, Liquids:

Q= Flow Rate, GPM (U.S.A.)
Cv= Valve Flow Coefficient
DP= Valve Pressure Drop, PSID
G= Specific Gravity of Liquid (= 1.0 for Water)

Standard Coil and DIN43650 Connector Option YC Weather Proof Housing with 1/2” NPT Threaded Conduit Connector
ORDERING INFORMATION
SELECT ITEM FROM EACH COLUMN IN CHART BELOW
EXAMPLE:1335BN3DT12DC
FOR YOUR CONVENIENCE, THESE ITEMS ARE AVAILABLE ONLINE
Model Body Material Seat & Seal Material Pipe Connection Configuration Connection Threads Voltage
1335   B= Brass A= Acrylo-Nitrile 3= 3/8” - = Pilot operated, Normally Closed T= NPT 12DC= 12 VDC
V= Viton 4= 1/2” 120AC= 120 VAC, 60 Hz
  6= 3/4” 24DC= 24VDC
 
Options
Prefix YC= Weather Proof Housing (1/2" NPT Thread)
Bold Order Combinations Typically Ship From Stock

Qty:

Show Discount Schedule


OR PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS
Model Body Material Seat & Seal Material Pipe Connection Configuration Connection Threads Voltage
1335   B= Brass A= Acrylo-Nitrile 3= 3/8” - = Pilot operated, Normally Closed T= NPT 12DC= 12 VDC
I= 316 SS V= Viton 4= 1/2” D = Direct Acting, Normally Closed - = BSP 120AC= 120 VAC, 60 Hz
  N= Neoprene 6= 3/4” A = Combined Acting, Normally Closed   24DC= 24VDC
E= Ethylpropylene   INA = Pilot operated, Normally Open 24AC= 24 VAC, 60 Hz
 
Options
Prefix YC= Weather Proof Housing (1/2" NPT Thread)
Suffix M= Manual Operation
Coil Indicator Light= Consult Factory
Bold Order Combinations Typically Ship From Stock

INSTALLATION RECOMMENDATIONS
Place a strainer with a porosity < 100µ upstream of valve (see Clark Solutions Model 1359 Y Strainer).
Install valve in any position, preferably on a horizontal pipeline with coil up.

For assistance call 978-568-3400