Clark Solutions
400 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches
1, 2 & 3 Switch output, Adjustable Ranges 30” Vac to 6000 PSI, -180 to 650°F

(Page 4 of 5)
Page 1 2 3 4 5

Range/Material Code Adjustable Set Point Max. Temp Scale Division Stem/Bulb Size OD x Length
°F °C °F °C °F °C
TEMPERATURE MODEL B400, B402, B403 INTERNAL ADJUSTMENT VIA REFERENCE DIAL

120

0 to 225

-17.8 to 107.2

275

135

5

5

9/16" x 1-7/8" below 1/2" NPT thread (nickel-plated brass)

121

200 to 425

93.3 to 218.3

475

246.1

5

5

9/16" x 1-7/8" below 1/2" NPT thread (nickel-plated brass)

TEMPERATURE MODEL C400, C402, C403 INTERNAL ADJUSTMENT, NO REFERENCE DIAL

120

0 to 225

-17.8 to 107.2

275

135

-

-

9/16" x 1-7/8" below 1/2" NPT thread (nickel-plated brass)

121

200 to 425

93.3 to 218.3

475

246.1

1-

-

9/16" x 1-7/8" below 1/2" NPT thread (nickel-plated brass)

TEMPERATURE MODEL E400, E402, E403 INTERNAL ADJUSTMENT VIA REFERENCE DIAL

2BSA

-120 to 100

-84.4 to 37.8

150

65.5

10

5

3/8 x 2-5/8"

2BSB

30 to 250

1.1 to 121.1

300

148.9

10

5

3/8 x 2-5/8"

3BS

100 to 400

37.8 to 204.4

450

232.2

10

10

3/8 x 2-1/8"

4BS

25 to 100

-3.9 to 37.8

150

65.5

5

2

3/8 x6-3/4"

5BS

-20 to 80

-28.9 to 26.7

130

54.4

5

2

3/8 x 5"

8BS

350 to 640

176.7 to 337.8

690

365.6

10

10

3/8 x 3-1/4"

TEMPERATURE MODEL F400, F402, F403 INTERNAL ADJUSTMENT, NO REFERENCE DIAL

Stainless steel bulb & capillary

1BS

-180 to 120

-115 to 48.9

170

76.6

-

-

3/8 x 3-3/4"

2BS

-125 to 350

-87.2 to 176.7

400

204.4

-

-

3/8 x 2-5/8"

3BS

-125 to 500

-87.2 to 260

550

287.7

-

-

3/8 x 2-1/8"

4BS

-40 to 120

-40 to 48.9

170

76.6

-

-

3/8 x 6-3/4"

5BS

-40 to 180

-40 to 82.2

230

110

-

-

3/8 x 5"

6BS

0 to 250

-17.8 to 121.1

300

148.8

-

-

3/8 x 4-1/2"

7BS

0 to 400

-17.8 to 204.4

450

232.2

-

-

3/8 x 3"

8BS

50 to 650

10 to 343.3

700

371.1

-

-

3/8 x 3-1/4"

ORDERING INFORMATION
PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS

SPECIFY MODEL NUMBER, RANGE CODE (FROM CHARTS) THEN OPTIONS IF REQUIRED
EXAMPLE: J400-5700140M201(10 PSI RISING)
Model - Pressure
J400 One SPDT output; internal adjustment with no reference dial
J402 Two SPDT outputs; internal adjustment with no reference dial
J403 Three SPDT outputs; internal adjustment with no reference dial
H400 One SPDT output; internal adjustment with reference dial
H402 Two SPDT outputs; internal adjustment with reference dial
H403 Three SPDT outputs; internal adjustment with reference dial
Model - Differential Pressure
J400K One SPDT output; internal adjustment with no reference dial
J402K Two SPDT outputs; internal adjustment with no reference dial
H400K One SPDT output; internal adjustment with reference dial
H402K Two SPDT outputs; internal adjustment with reference dial
Model - Temperature
B400 Immersion stem; one SPDT output; internal adjustment with reference dial
B402 Immersion stem; two SPDT outputs; internal adjustment with reference dial
B403 Immersion stem; three SPDT outputs; internal adjustment with reference dial
C400 Immersion stem; one SPDT output; internal adjustment with no reference dial
C402 Immersion stem; two SPDT outputs; internal adjustment with no reference dial
C403 Immersion stem; three SPDT outputs; internal adjustment with no reference dial
E400 Bulb and capillary; one SPDT output; internal adjustment with reference dial
E402 Bulb and capillary; two SPDT outputs; internal adjustment with reference dial
E403 Bulb and capillary; three SPDT outputs; internal adjustment with reference dial
F400 Bulb and capillary; one SPDT output; internal adjustment with no reference dial
F402 Bulb and capillary; two SPDT outputs; internal adjustment with no reference dial
F403 Bulb and capillary; three SPDT outputs; internal adjustment with no reference dial
Switch Options
NO SWITCH OPTIONS ARE AVAILABLE FOR PRESSURE RANGES 440 TO 443
0140 Gold contacts, 1A 125 VAC resistive
0500 Close deadband, 5A 125/250 VAC resistive
1010 DPDT switch,10 A 125/250 VAC resistive.  NOT AVAILABLE TEMPERATURE VERSIONS OR MODEL J403 AND RANGE CODES 448-449, 520-535, 540-547, 570-572
1070 10 A 125 VDC resistive; deadband and minimum set point will increase. NOT AVAILABLE ON MODELS B & E OR RANGE CODES 448-449, 520-535, 540-547, 570-572
1520 Adjustable deadband, 15 A 125/250/277 VAC resistive. NOTE: FOR MODEL J403, NOT AVAILABLE ON MIDDLE SWITCH. NOT AVAILABLE ON MODEL TYPES B,E,H,C403,F403 OR RANGE CODES 520-535, 540-547, 570-572, 610-614
1530 External manual reset,15 A 125/250/480 VAC resistive; latches on rise only. NOT AVAILABLE ON MODEL 403 OR RANGE CODES 520-535, 570-572
1535 High ambient,15 A 125/250 VAC resistive; temperatures up to 250 °F (145 °C). NOT AVAILABLE ON MODELS 520-535
1537 Vapor sealed switch,15 A 125/250 VAC resistive. NOT AVAILABLE ON RANGE CODES 520-535
1539 Fungus resistant case,15 A 125/250 VIC resistive. NOT AVAILABLE ON RANGE CODES 520-535
2000 20 A 125/250/300 VAC resistive. NOT AVAILABLE ON RANGE CODES 520-535, 540-547, 570-572
Other Options
M020 Red status light,115 VAC only. Specify whether light goes on or off with increasing or decreasing pressure or temperature.
M201 Factory set one switch; specify increasing or decreasing pressure or temperature and setpoint
M202 Factory set two switches. NOT AVAILABLE SINGLE SWITCH VERSIONS
M203 Factory set three switches; note: the third or middle switch must always be set to highest pressure or temperature when switches are set apart. NOT AVAILABLE SINGLE OR DUAL SWITCH VERSIONS
M276 Range indicated on nameplate in bars/mbars.  NOT AVAILABLE ON TEMPERATURE VERSIONS
M278 Range indicated on nameplate in Kg/cm2. NOT AVAILABLE ON TEMPERATURE VERSIONS
M321 Gasketed Lexan® window.  NOT AVAILABLE ON J,C,F TYPES
M444 Paper ID tag
M446 Stainless steel ID tag & wire attachment
M504 316L stainless steel immersion stem.  AVAILABLE ON MODELS 120,121 ONLY
M540 Viton® construction (deadband and low end range may increase slightly); wetted parts include Viton® diaphragm and O-ring plus standard connection material. Deadbands increase approximately 15% and low end of range will increase 10%.  AVAILABLE MODELS 448-457,610-614,540-547
M550 Oxygen service cleaning; internal construction may change. NOT AVAILABLE ON MODELS 440-443
M900 Watertight conduit fitting; converts 7/8” hole to 1/2” NPT fitting. Required for product to meet NEMA 4X
6361-704 Surface Mounting Hardware required for models 520-535, 540-547
Optional Sensor Material for “WC Ranges. Available Models 520-525
XC001 Aluminum pressure connection, Viton® diaphragm, Viton® O-ring
XC002 Aluminum pressure connection, Kapton® diaphragm, Buna-N O-ring
XC003 Aluminum pressure connection, Kapton® diaphragm, Viton® O-ring
XC004 316L Stainless steel pressure connection, 316L stainless steel diaphragm, Viton® O-ring. (Over range pressure is limited to 100 psi)
XC005 316L Stainless steel pressure connection, Viton® diaphragm, Viton® O-ring
XC006 316L Stainless steel pressure connection, Kapton® diaphragm, Viton® O-ring
XC007 316L Stainless steel pressure connection, Teflon® diaphragm, Viton® O-ring
Viton® is a registered trademarks of DuPont Dow Elastomers.
Kapton® and Teflon® are registered trademarks of E.I.DuPont.
Lexan® is a registered trademark of General Electric Company
Page 1 2 3 4 5
For assistance call 978-568-3400
pumps | valves | instrumentation | new products | contact clark | site/product directory | enewsletter | home