511 Series Low Cost Pressure Transmitter
Liquids And Gases, FS Ranges 30" Hg Vacuum to 7500 PSI
DESCRIPTION
These compact Low Cost pressure transmitters meet the highest specification for mechanical stress, EMC compatibility, and operational reliability.
Model 511 is particularly suitable for demanding industrial applications. The sensor utilizes a ceramic technology developed by Huba Control of Switzerland. Millions sold over the past 10 years demonstrate the reliability of the ceramic sensor design that utilizes integrated (to the sensor) electronics.
The integrated sensor/electronic design has a high degree of accuracy over wide temperature range.
|
|
 |
|
|
 |
|
|
 |
|
|
|
|
|
 |
|
|
* HIGH RESISTANCE TO EXTREME TEMPERATURE
* COMPACT, RUGGED CONSTRUCTION
* PATENTED RUPTURE SEALING DEVICE IN
CONNECTOR
* PREVENTS MEDIA LEAKAGE IN EVENT OF
SENSOR FAILURE
*ATTRACTIVE PRICE TO PERFORMANCE RATIO
|
|
|
|
|
SPECIFICATIONS
Pressure Measurement: Absolute pressure & gage pressure (differential
measurement of pressure relative to ambient pressure).
F.S. Pressure Ranges: -1 to 600 bar (-14.5 to 8700 PSI)
Maximum/Rupture Pressure:
3.0x Full scale at - 1
4 bar
2.5x Full scale at 6
400 bar
2.0x Full scale at 600 bar
Higher rupture pressure on request
A patented media stop system prevents media egress when
exceeding rupture pressure range (40 bar nominal value)
Accuracy:
Total of linearity, hysteresis and repeatability: < +/- 0.3% fs
Adjustment accuracy zero point and full scale: < +/- 0.3% fs
Casing: Stainless steel 1.4305 (AISI 303)
Materials In Contact With The Medium:
Ceramic Al2O3
Stainless steel 1.4305 (AISI 303)
Rupture Seal: PPS
Seal Material:FPM, NBR, others on request
Media Temperature With Sealing Materials:
FPM - 15
+ 125°C
NBR - 25
+ 85°C
FPM SPEC. - 40
+ 150°C
Ambient Temperature: Max. 85 °C
(Versions up to 150°C on request)
Temperature Influences:
Zero < +/- 0.015% fs/°C
Span < +/- 0.015% fs/°C
Temperature range - 40
+ 125 °C
Dynamic Response: Suitable for static and dynamic measurements.
Response time < 2 ms, typ. 1 ms
Pressure Connections: See order code selection table
Weight: Version inside thread 85 grams
Version outside thread 95 grams
Installation Orientation: Unrestricted
Signal/Power Supply: See order code selection table
Protection: Short circuit-proof and protected against polarity reversal.
Each connection is protected against other with max. +/- supply
voltage.
Electric strength 500 VDC, on request 1000 VDC
Load:
Voltage outputs: > 10 kOhm / < 100 nF
Current Output: Max 1250 Ohms
Current Consumption With Max. Signal Output:
Voltage outputs: < 4 mA
4 - 20 mA: < 20 mA
Electrical connections : M12 x 1 or cable, 1.5 meters (other connectors
available on request) |
|
|
 |
|
 |
|
|
| TESTING |
|
| Shock according to IEC 68-2-27: 75 G, 11 ms half sine wave, all 3 directions. Free fall from 1 m on concrete (6x). |
| Constant shock according to IEC 68-2-29: 40 G for 6 ms, 1000x all 3 directions. |
Vibration according to IEC 68-2-6: 20 G, 9 ... 200 Hz, 2 ... 9 Hz with amplit +/- 15 mm, 1 Octave / min.all 3 directions, 50
constant load. |
Electromagnetic compatibility: CE conformity (EMC) by application of harmonized standards: Interference stability EN 50082-2, IEC
61000-6-2 and EN 61326-1, interference emit EN 50081-1, EN 55022, CISPR 22, EN 61326-1 |
| Interference Stability |
Test Standard |
Effects |
| Electrostatic discharge (ESD) |
EN 61000-4-2 |
No effect |
| 15 kV air discharge, 8 kV contact discharge |
| High-frequency electromagnet radiation (HF) |
EN 61000-4-3 |
No effect |
| 200 V/m, 80 ... 1000 Mz |
| Conducted HF interference |
EN 61000-4-6 |
No effect |
| 30 V, 0.15 ... 80 MHz |
| Fast transients (burst) |
EN 61000-4-4 |
No effect |
| 4 kV |
| Surge |
EN 61000-4-5 |
No failure |
| Line-Line, Line-Case 500 V, 12 Ohm, 9 µF |
| 1 kV, 42 Ohm, 0.5 µF |
| Magnetic fields |
EN 61000-4-8 |
No effect |
| 30 A/m, 50 Hz |
| Insulation voltage |
500 VDC (optional 1000 VDC) |
No effect |
| 350 VAC (optional 700 VAC) |
| Interference Emit |
Test Standard |
Effects |
| |
EN 55022 |
|
| Conducted interference |
0.15... 30 MHz |
No emission |
| Radiation from housing |
30...1000 MHz, 10 meters |
No emission |
|
|
ORDERING INFORMATION
MODEL NUMBER ABCDEFGH
Example: 511-9A1003031 |
|
|
| FOR YOUR CONVENIENCE, THESE ITEMS ARE AVAILABLE ONLINE |
| A=Model |
B=Type |
*C=Range |
D=Seals |
E=Output |
F=Elect. Connections |
G=Press. Connections |
H=Connection Orifice |
| 511 |
9=Gage pressure |
A1= 0 to 30?Hg Vacuum |
00=FPM |
3=4-20 mA (2-wire, 8-33VDC) |
0=1.5 Meter Cable |
3= 1/4-18 NPT |
1=Without (ranges to 300 psi) |
| B1= 0 to 15 PSI |
| B4= 0 to 30 PSI |
2=With (ranges 500psi and greater) |
| B5= 0 to 60 PSI |
| B7= 0 to 100 PSI |
|
| C1= 0 to 200 PSI |
| C2= 0 to 300 PSI |
| C3= 0 to 500 PSI |
| D0= 0 to 1000 PSI |
| D2= 0 to 2000 PSI |
| D3= 0 to 3000 PSI |
| * Ranges in other units of pressure such as bar are available. Special ranges available on request. |
| Consult us with special requirements |
| BOLD ITEMS ARE TYPICALLY IN STOCK (2-3 week delivery for non-stock items) |
|
|
|
|
|
|
| PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS |
| A=Model |
B=Type |
*C=Range |
D=Seals |
E=Output |
F=Elect. Connections |
G=Press. Connections |
H=Connection Orifice |
| 511 |
9=Gage pressure |
A1= 0 to 30?Hg Vacuum |
00=FPM |
3=4-20 mA (2-wire, 8-33VDC) |
0=1.5 Meter Cable |
3= 1/4-18 NPT |
1=Without (ranges to 300 psi) |
| 8=Absolute pressure |
B1= 0 to 15 PSI |
20=NBR |
1= 0-5 V |
1=M12 x 1 (without female connector) |
6= 1/8-27 NPT |
2=With (ranges 500psi and greater) |
| |
B4= 0 to 30 PSI |
60=FPM SPEC |
2= 0-10 V (3-wire, 8-33VDC) |
|
1=G1/4 female |
|
| B5= 0 to 60 PSI |
|
|
5= M12 x 1.5 male |
| B7= 0 to 100 PSI |
6= M14 x 1.5 male |
| C1= 0 to 200 PSI |
|
| C2= 0 to 300 PSI |
| C3= 0 to 500 PSI |
| D0= 0 to 1000 PSI |
| D2= 0 to 2000 PSI |
| D3= 0 to 3000 PSI |
| E46= 0 to 5000 PSI (FPM SPEC seal only) |
| E56= 0-7500 PSI (FPM SPEC seal only) |
| |
| Accessories & Options: |
| 106975=Female connector for M12 x 1 |
| Packaging: |
| Single=Single Package for each transmitter |
| Multiple=Packaged in 25 piece lots |
| |
| * Ranges in other units of pressure such as bar are available. Special ranges available on request. |
| Consult us with special requirements |
| BOLD ITEMS ARE TYPICALLY IN STOCK (2-3 week delivery for non-stock items) |
|
|
For assistance call 978-568-3400
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|