Pressure Transmitter, 652 Series Differential Pressure Transmitter
•HIGH OVERPRESSURE SAFETY
  PROTECTION
•RUGGED MECHANICS WITH HIGH
  OPERATING RELIABILITY
•COMPATIBLE WITH SLIGHTLY
  AGGRESSIVE LIQUIDS AND GASES
•ATTRACTIVE PRICE TO PERFORMANCE
  RATIO

HUBA
652 Series Differential Pressure Transmitter
Liquids And Gases, F.S. Ranges 20 inches w.c to 15 PSID

DESCRIPTION
The differential pressure transmitter series 652 are especially suited for the continuous level or flow monitoring of neutral and slightly aggressive liquids and gases in heating, ventilation and process applications.

The pressure or differential pressure to be monitored acts on a diaphragm, which in turn acts against a spring. A permanent magnet fastened on the diaphragm moves in the direction of a hall sensor mounted outside the pressure case. This sensor emits an electrical signal which is proportional to the magnetic field. The signal is linearized, compensated and amplified.

1) Pressure case
2) Diaphragm
3) Permanent magnet
4) Printed Circuit board
5) Cover
6) PG9 Strain Relief
7) Vent
P1 Higher Pressure, Lower Vacuum
P2 Lower pressure, Higher Vacuum
SPECIFICATIONS
Pressure ranges: See ordering information.
Max Pressure:
       145 PSI range 20.0“ w.c.
       290 PSI range 7 PSID and higher
Rupture pressure: 435 PSI
Linearity: < +/- 1.5 % fs
Hysteresis: < +/- 1.5 % fs
Zero point offset < +/- 1.0 % fs
Pressure case: Anodized black aluminium, brass or
       nickel-plated brass
Cover: plastic
Diaphragm: NBR-based, EPDM, Viton
Materials Coming Into Contact With Media:
       430F SS
       304 SS
       301 SS
       AISI A2 Alloy screws
       Polyacetate-C / Polyamide
Operating Temperature: NBR-based, 32-176 °F
       (0-80 °C); FPM, 14-176 °F(-10-80 °C); EPDM,
       14-176 °F( -10-80 °C)
Operating Temperature PC Board: -13-140 °F
       (-25-60 °C)
 
Temperature Drift: 0.08% fs / degree from
       Calibration Temperature (20 °C) 
Response Time: < 10 ms
Pressure connections: 1/8 NPT female thread
Weight Aluminum Pressure Case :13 oz
Weight Brass/Nickel-Plated Brass Case: 1.9 lbs
Installation: The transmitter is calibrated in the
       factory with the diaphragm positioned
       vertically. In the case of liquid media, vent
       screw should be oriented up and the
       pressure connections down.
Outputs: 0 -10 V, 3-wire cable ; 4-20 mA
       3-wire cable
Installation Warmup Time: 15 minutes
Power supply: 20 - 30 VDC
Current load: < 300 Ohm
Voltage load: < 10 KOhm
Current Consumption:
       0 - 10 V- 35 mA
       4 - 20 mA- max. 55 mA
Case material
1) Anodized Aluminum
2) Brass
3) Nickel Plated Brass
4) Mounting brackets
 
DIMENSIONS (MM) & ELECTRICAL
   
ORDERING INFORMATION
MODEL NUMBER ABCDEFGHI
Example: 652.934100N20

FOR YOUR CONVENIENCE, THESE ITEMS ARE AVAILABLE ONLINE
A=Model B=Range C=Output D=Linearity E=Power F=Elect. Connections G=Press. Connections H=Case I=Diaphragm
652.9 1=0-20"w.c. 4=4-20mA 1=±1.5% fs 0=20-30VDC 0=Screw Terminals N=1/8 FNPT 2=Nickel Plated Brass 0=NBR-Based
3= 0-7.0 PSID
4= 0-15 PSID
 
Accessories & Options:
A01: Type A mounting bracket
Higher Accuracies on Request
Special Ranges Available On Request

Qty:

Show Discount Schedule

PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS
A=Model B=Range C=Output D=Linearity E=Power F=Elect. Connections G=Press. Connections H=Case I=Diaphragm
652.9 1=0-20"w.c. 4=4-20mA 1=±1.5% fs 0=20-30VDC 0=Screw Terminals N=1/8 FNPT 2=Nickel Plated Brass 0=NBR-Based
3= 0-7.0 PSID 0=0-10V 0=Anodized Aluminum 1=FPM
4= 0-15 PSID   1=Brass 2=EPDM
 
Accessories & Options:
A01: Type A mounting bracket
A02: Type B mounting bracket
Higher Accuracies on Request
Special Ranges Available On Request

ASK US ABOUT OUR....

LOW PRESSURE AIR
TRANSMITTERS & SWITCHES
Wet to Wet Transmitters & Switches
Wet to Wet Transmitters & Switches
For assistance call 978-568-3400