ALMEMO Output Connections
RS232, Modem, Analog Signal Retransmission, PID Control, Alarm Relay Output
RS232 CONNECTION
To connect AMR devices to a PC or Printer via 9-Pin Sub-D Connector
FOR YOUR CONVENIENCE, THESE ITEMS ARE AVAILABLE ONLINE
OR PLEASE CALL 1-800-253-2497 TO ORDER |
| Model |
Description |
| ZA1909-DK |
Standard RS232 Connector Cable, 5-foot cable |
| ZA1999-NK5 |
"Daisy Chain" cable to connect two AMR Devices together to make an AMR Device Network |
| ZA1909-DKL |
Fiber-Optic version of ZA1909-DK, ensures electrical isolation, 5-foot cable |
| ZA1601-RK |
Analog Output Cable (for use with chart recorder), Output voltage -1.250 to 2.000, Current Cons. 3 mA max., load >1kohm, 1.5m |
| ZA1000-EGK |
Output cable for limit value alarm Set of dry contacts rated 24V, 10mA |
MODEM CONNECTION
Connect remote AMR device(s) to a modem and dial them up from a PC. Allows for all programming functions and memory download capabilities, just as if device was connected locally. Can connect to single AMR device or AMR device network.
| PLEASE CALL 1-800-253-2497 TO ORDER THIS ITEM |
| Model |
Description |
| ZA1709-MK |
Modem, specially-programmed to support AMR device communications |
|
|
|
 |
|
Get a printer friendly Acrobat file for each of the following:
|
|
|
|
|
 |
|
MULTIPLE ALARM RELAY OUTPUTS, ANALOG RETRANSMISSION, PID CONTROL
The ZA8000-RTA comes standard with 4 SPDT alarm relays. It is connected to AMR loggers using the 2nd digital output socket (socket A2). The ZA8000-RTA's functions (alarm relays and any optional output signals) are referenced to the AMR logger to which it is connected. It has its own digital output (A2) socket, so daisy-chaining loggers together with the ZA8000-RTA in between is possible. The alarms may be assigned to a specific channel or to all channels. Optional voltage or current outputs are available, and provide for analog retransmission of measured values. When used with WIN-Control software, these analog outputs may be converted to proportional control signals, allowing for PID control of processes. The ZA8000-RTA operates on 12VDC, or by AC/DC adapter #ZB3090-NA/USA. |
|
| PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS |
| Model |
Description |
| ZA8000-RTA |
Relay/Analog Output Module, includes 4 ea. SPDT relays |
| ZB3090-NA/USA |
AC/DC Adapter for ZA8000-RTA |
| OA8000-R1 |
Voltage Analog Output Option, -1.2500
+2.0000 VDC |
| OA8000-R2 |
Voltage Analog Output Option, -6.0000
+10.0000 VDC |
| OA8000-R3 |
Current Analog Output Option, 0.0000 (4.0000)
+20.0000 mA |
| OA8000-H |
Fixture for DIN Rail Mounting |
| OA8000-L |
Bracket for Wall or Device Mounting |
|
|
|
|
|
DUAL ALARM RELAY OUTPUT
The ZA1000-EGK/EAK relay output cable allows for two SPST-NO switch outputs. The cable is connected to an AMR logger's second digital output socket (A2). The alarms may be assigned to a specific channel or all channels on the logger. The ZA1000-EGK is used when the alarm setpoints are programmed locally into the AMR logger. The ZA1000-EAK is used when the alarm setpoints are set using WIN-Control software and are not programmed locally in the logger.
|
|
| PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS |
| Model |
Description |
| ZA1000-EGK |
Dual Alarm Relay Output Cable, for use with alarm setpoints programmed at the logger |
| ZA1000-EAK |
Dual Alarm Relay Output Cable, for use with alarm setpoints programmed through WIN-Control software |
|
|
ANALOG OUTPUT CABLE
For connecting an AMR logger to an external device such as a chart recorder. The output is -1.250
+2.000 VDC. The voltage output is equivalent to 0.1mV per digit (i.e., a humidity reading of 45.67% would create an output of 456.7mV). Cable Length is 5 feet. Electrical Connections are via banana plugs. Output signal is assigned to whatever measuring channel is currently being displayed on the logger.
|
|
|
| PLEASE CALL 1-800-253-2497 TO ORDER THIS ITEM |
| Model |
Description |
| ZA1601-RK |
Analog Output Cable, -1.250
+2.000 VDC, 0.1mV/digit |
|
|
|