DS03 Flow Meter/Switch CLARK SOLUTIONS
DS03 Flow Meter/Switch
F.S. Ranges From 1.5 to 50 l/min water, 30 to 1600 l/min air

DESCRIPTION
The flow meter and switch model DS03 works according to a modified variable area principle. The float is guided in a cylindrical measuring glass by means of a spring. The flowing medium moves the float in the flow direction. The upper edge of the float shows the momentary flow via an etched scale on the measuring glass.

A reed contact is mounted outside the meter in a sealed housing. When the float reaches the position of the reed contact the switch will close. With higher flows the float moves further upward until it reaches a built-in float stop, still keeping the switch closed. This ensures a bistable switch function at any time. The reed contact is adjustable over the full switching range of the meter.


SPECIFICATIONS
Max Pressure: 10 bar (145 PSIG)
Pressure Drop: 0.01-0.2 bar
  (0.2-2.9 PSI)
Max Temperature: 120°C (optionally
  160°C) for liquids, 90°C for gases
Materials:
Measuring Glass - Duran 50
Housing - Aluminum
Connections - Brass or Stainless
O-rings -
              Brass Version - Buna
              Stainless Version - Viton  
Electrical Connections- DIN 43650 plug
Accuracy - ±5% f.s.
Ranges:
Water - 0.1-1.5 l/min to 10-150 l/min
Air - 3.0-30 l/min to 350-2750 l/min
  (at 1.013 bar absolute and 20oC)

APPLICATION
The variable area flow meter and switch model DS03 is used for measuring and monitoring the flow of low viscosity liquids and gases, i.e., in cooling loops of welding machines and laser systems, for pump monitoring, compressors and many other applications.


FEATURES

Small Mounting Dimensions

Brass or Stainless Steel Connections

Scales for Water and Air


High Switching Accuracy

Low Switching Hysteresis
CONTACTS
Function      
N/O: 250V 3A 100VA
SPDT:  250V 1.5A 50VA
*EX-N/O:  250V 2A 60 VA
*EX-SPDT:  250V 1A 30VA
*Per ATEX 100aEXII 2 G, EEx m II T6
DIMENSIONS
Model Dimensions in mm Weight (g)
SW D B G T L
DS03.1.x.x.x 32 43 67 1/4 NPT 14 132 625
DS03.2.x.x.x 32 43 67 1/2 NPT 15 135 625
DS03.2.x.x.05 32 43 67 1/2 NPT 15 163 650
DS03.3.x.x.05 32 43 67 3/4 NPT 16 167 650
DS03.3.x.x.06/07 41 50 70 3/4 NPT 18 152 1000
DS03.4.x.x.06/07 41 50 70 1.0 NPT 19 156 1000
DS03.4.x.x.08 41 50 70 1.0 NPT 20 200 1100
DS03.5.x.x.x 46 55 75 1-1/4 NPT 21 222 1300
DS03
Electrical Connection
ORDERING INFORMATION
Order Number Example DS031N11WA01110
Miniature variable area flow meter and switch
PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS
Connection:  1N = 1/4" female NPT 2N = 1/2” female NPT 3N = 3/4” female NPT 4N= 1” female NPT 5N= 1 1/4" female NPT
Material: 1 = brass with 301 stainless steel spring  2 = all 316 stainless steel 
Scale: 1 = for water 2 = for air 
Measuring Ranges:   Water Air
DS03.1 & DS03.2: WA01= 0.1-1.5 l/min  LA01= 3.0-30 slpm
WA02= 0.2-3.0 l/min  LA02= 6.0-60 slpm
WA03= 0.3-8.0 l/min  LA03= 6.0-160 slpm 
WA04= 1.0-12 l/min  LA04= 20-220 slpm
DS03.2 & DS03.3 WA05= 2.0-18 l/min  LA05= 40-360 slpm
DS03.3 or DS03.4 WAO6= 3-35 l/min  LA06=60-700 slpm
WA07= 4-50 l/min  LA07=60-825 slpm
DS03.4 Only   LA08= 200-1600 slpm 
No. of contacts: 1 = 1 contact  2 = 2 contacts 
Contact function: 1 = N/O  2 = SPDT 3S= Ex-N/O (EEX m II T6) 3U= Ex-SPDT (EEX m II T6) 
Options: 0 = Without 1 = Please List
For assistance call 978-568-3400
pumps | valves | instrumentation | new products | contact clark | site/product directory | enewsletter | home