CLARK SOLUTIONS
Variable Area Flowmeter And Switch For High Pressure Applications
DESCRIPTION
The flow meter and switch model DS04 works according to a modified variable area principle. The float is guided in a cylindrical measuring tube by means of a slotted nozzle. The flowing medium moves the float in the flow direction. An externally mounted pointer indicator is magnetically coupled to the float and thus, following the float position, indicates the flow rate on a scale.
A Reed contact is mounted outside the meter in a sealed housing. When the float reaches the position of the Reed contact the switch will close. With higher flows the float moves further upward until it reaches a built-in float stop, still keeping the switch closed. This ensures a bistable switch function at any time. The Reed contact is adjustable over the full measuring and switching range of the meter.
TECHNICAL SPECIFICATIONS
Max Pressure:
brass version: 2900 psi/200 bar
stainless steel version: 4350 psi/300 bar
Pressure Drop: 0.29-5.8 psi/0.02-0.4 bar
Max Temperature: 212°F/100°C
(320°F/160°C on request) for liquids
194 °F / 90 °C for gases
Materials:
Wetted Parts: brass version: nickel plated
brass
stainless steel version: st. steel 316
Ti/1.4571
O-rings: Buna (optionally: Viton, EPDM)
Electrical plug acc. to DIN 43650
Connection: (optionally: 1m cable
connection)
Accuracy: ±5% f.s. for water,
± 10% f. s. for air
Analog output: see model DSxx-A in
section "accessories"
|
|
 |
|
|
FEATURES
Small Mounting Dimensions
Materials: Brass or Stainless Steel
Scales for Water and Air
High Switching Accuracy
Very Small Switch Hysteresis
Robust Design without Glass Measuring Tube
Suitable for Pressures up to 4350 psi / 300 bar
APPLICATION
The variable area flow meter and switch model DS04 is used for
measuring and monitoring the flow of low viscosity liquids and gases,
i.e., in cooling circuits of welding machines and laser systems, for
pump monitoring, compressors and many other applications.
VERSIONS
- flow switch only with Reed contact
- optionally as flow meter and switch with external pointer
indicator and contact
MEASURING RANGES
Water: 1.5-23.8 GPH … 65-790 GPH
Air: 2-59 SCFH … 7-51 SCFM
(at 14.7 psia/1.013 bar abs. and 68°F/20°C)
MATERIALS
brass or stainless steel |
|
|
| CONTACTS |
| Function |
|
| N/O: |
250V, 3A, 100VA |
| SPDT: |
250V, 1.5A, 30VA |
| *EX-N/O: |
250V, 2A, 60VA |
| *EX-SPDT: |
250V, 1A, 30VA |
| *Per ATEX 100aEXII 2 G, EEx m II T6 |
|
|
|
|
|
|
|
| Model |
Mounting dimensions in inch / mm |
Weight (lbs / g) |
| SW |
D |
D1 |
B |
NPT / G |
T |
L |
without indication |
with indication |
| DS04.1.x.x.x |
1.06/27 |
1.18/30 |
1.85/47 |
2.80/71 |
1/4" |
0.55/14 |
5.12/130 |
1.76/800 |
1.87/850 |
| DS04.2.x.x.x |
1.06/27 |
1.18/30 |
1.85/47 |
2.80/71 |
1/2" |
0.59/15 |
5.12/130 |
1.76/800 |
1.87/850 |
| DS04.2.x.x.05 |
1.06/27 |
1.18/30 |
1.85/47 |
2.80/71 |
1/2" |
0.59/15 |
5.83/148 |
1.87/850 |
1.98/900 |
| DS04.3.x.x.x |
1.34/34 |
1.57/40 |
2.24/57 |
2.80/71 |
3/4" |
0.71/18 |
5.98/152 |
2.97/1350 |
3.08/1400 |
| DS04.4.x.x.06/07 |
1.42/36 |
1.42/36 |
2.09/53 |
2.99/76 |
1" |
0.75/19 |
6.14/156 |
2.31/1050 |
2.42/1100 |
| DS04.4.x.x.08 |
1.97/50 |
1.97/50 |
2.64/67 |
2.99/76 |
1" |
0.79/20 |
7.87/200 |
6.06/2750 |
6.17/2800 |
|
|
 |
|
|
|
|
 |
|
ORDERING INFORMATION
Order Number Example: DS04. 4. 1. 1. WA06. 1. 1. 1. 0
Variable Area Flowmeter And Switch For High Pressure Applications
|
|
|
| Model |
Connection |
Material |
Scale |
Measuring ranges |
Version |
No. of contacts |
Contact function |
| DS04.1 and DS04.2 |
DS04.2 and DS04.3 |
DS04.3 and DS04.4 |
DS04.4 only |
| Water |
Air |
Water |
Air |
Water |
Air |
Air |
| DS04 |
1N=1/4" NPT female |
1=brass |
1=for water |
WU01=1.523.8 GPH |
LU01=259 SCFH |
WU05=32285 GPH |
LU05=80760 SCFH |
WU06=50555 GPH |
LU07=224.5 SCFM |
LU08=751 SCFM |
0=switch only, without flow rate indication |
0=without contact |
0=without contact |
| 2N=1/2" NPT female |
2=all st. steel AISI 316 Ti/1.4571 |
2=for air (at 14.7 psia/1.013 bar abs. and 68°F/20°C) |
WU02=3.047.5 GPH |
LU02=8127 SCFH |
WA05=2-18 l/min |
LA05=40-360 Nl/min |
WU07=65790 GPH |
LA06=60-700 Nl/min |
LA08 = 200 - 1400 Nl/min
|
1=1 contact |
1=N/O |
| 3N=3/4" NPT female |
WU03=1.0127 GPH |
LU03 = 15 340 SCFH |
|
|
WA06=3-35 l/min |
LA07=80-1000 Nl/min |
|
2=2 contacts |
2=SPDT |
| 4N=1" NPT female |
|
WU04=16190 GPH |
LU04=40510 SCFH |
WA07=4-50 l/min |
1=flow meter and switch, with side indicator |
|
3S=Ex-N/O (EEx m II T6) |
| 1=G 1/4 female |
|
WA01=0.1-1.5 l/min |
LA01=1-28 Nl/min |
|
|
3U=Ex-SPDT (EEx m II T6) |
| 2=G 1/2 female |
WA02=0.2-3 l/min |
LA02=4-60 Nl/min |
|
| 3=G 3/4 female |
WA03=0.3-8 l/min |
LA03=6-160 Nl/min |
|
| 4 = G 1 female |
WA04=1-12 l/min |
LA04=20-240 Nl/min |
| |
| Options |
| 0 = without |
| 1 = please indicate |
|
|
 |
|
|
|
This product sold by PKP Process Instruments, Inc., a joint venture of Clark Solutions