CLARK SOLUTIONS
DS04 Flow Meter/Switch
F.S. Ranges From 1.5 to 150 l/min water, 1 to 1400 l/min air
DESCRIPTION
The flow meter and switch model DS04 works according to a modified variable area principle. The float is guided in a cylindrical measuring tube by means of a slotted nozzle. The flowing medium moves the float in the flow direction. An externally mounted pointer indicator is magnetically coupled to the float. It follows the float position and indicates the flow rate on a scale.
A reed contact is mounted outside the meter in a sealed housing. When the float reaches the position of the reed contact the switch will close. With higher flows the float moves further upward until it reaches a built-in float stop, still keeping the switch closed. This ensures a bistable switch function at any time. The reed contact is adjustable over the full measuring range of the meter.
SPECIFICATIONS
Max Pressure:
Brass- 200 bar (2900 PSIG)
Stainless Steel- 300 bar (4,350 PSIG)
Pressure Drop: 0.02-0.4 bar (0.3-5.8 PSI)
Max Temperature: 120°C (optionally
160°C) for liquids, 90°C for gases
Materials:
Wetted Parts- Nickel plated brass or
316Ti SS
O-rings-
Brass Version - Buna
SS Version - Viton
Electrical Connections- DIN 43650 plug
Accuracy- ±5% f.s.
Ranges:
Water- 0.1-1.5 l/min to 10-150 l/min
Air- 1.0-28 l/min to 20-1400 l/min
(at 1.013 bar absolute and 20°C)
|
|
|
 |
|
|
APPLICATION
The variable area flow meter and switch model DS04 is used for measuring and monitoring the flow of low viscosity liquids and gases, i.e., in cooling loops of welding machines and laser systems, for pump monitoring, compressors and many other applications.
FEATURES
Small Mounting Dimensions
Brass or Stainless Steel Connections
Scales for Water and Air
High Switching Accuracy
Low Switching Hysteresis |
|
|
| CONTACTS |
| Function |
|
|
|
| N/O: |
250V |
3A |
100VA |
| SPDT: |
250V |
1.5A |
50VA |
| *EX-N/O: |
250V |
2A |
60 VA |
| *EX-SPDT: |
250V |
1A |
30VA |
| *Per ATEX 100aEXII 2 G, EEx m II T6 |
|
|
|
|
| DIMENSIONS |
| Model |
Dimensions in mm |
Weight |
| with |
w/o |
| SW |
D |
D1 |
B |
G |
T |
L |
Indication |
| DS04.1.x.x.x |
27 |
30 |
47 |
65 |
1/4 NPT |
14 |
130 |
800 |
850 |
| DS04.2.x.x.x |
27 |
30 |
47 |
65 |
1/2 NPT |
15 |
130 |
800 |
850 |
| DS04.2.x.x.05 |
27 |
30 |
47 |
65 |
1/2 NPT |
15 |
148 |
850 |
900 |
| DS04.3.x.x.x |
34 |
40 |
57 |
70 |
3/4 NPT |
18 |
152 |
1350 |
1400 |
| DS04.4.x.x.06/07 |
36 |
36 |
53 |
68 |
1.0 NPT |
19 |
156 |
1050 |
1100 |
| DS04.4.x.x.08 |
50 |
50 |
67 |
75 |
1.0 NPT |
20 |
200 |
2750 |
2800 |
| DS04.5.x.x.x |
50 |
50 |
67 |
75 |
1.0 NPT |
21 |
200 |
2950 |
3000 |
|
|
|
 |
|
|
|
 |
|
|
|
ORDERING INFORMATION
Order Number Example DS041N11WA011120
Miniature variable area flow meter and switch
|
|
|
| PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS |
| Connection: |
1N = 1/4 female NPT |
2N= 1/2 female NPT |
3N = 3/4 female NPT |
4N = 1 female NPT |
5N= 1 1/4 female NPT |
| Material: |
1= brass with 301 stainless steel spring |
2= all 316 stainless steel |
| Scale: |
1= for water |
2= for air |
| Measuring Ranges: |
Water |
Air |
| DS04.1 & DS04.2: |
WA01= 0.1-1.5 l/min |
LA01= 1.0-28 slpm |
| WA02= 0.2-3.0 l/min |
LA02= 4.0-60 slpm |
| WA03= 0.3-8.0 l/min |
LA03= 6.0-160 slpm |
| WA04= 1.0-12 l/min |
LA04= 20-240 slpm |
| DS04.2 & DS04.3 |
WA05= 2.0-18 l/min |
LA05= 40-360 slpm |
| DS04.3 & DS04.4 |
WA06= 3.0-35 l/min |
LA06= 60-700 slpm |
| WA07= 4.0-50 l/min |
LA07= 80-1000 slpm |
| DS04.4 Only |
|
LA08= 200-1400 slpm |
| Version: |
0= Switch only, without flow indication |
1= Flow meter and switch, with side indicator |
| No. of Contacts: |
1= 1 Contact |
2= 2 Contacts |
| Contact Function: |
1= N/O |
2= SPDT |
3S= Ex-N/O (EEX m II T6) |
3U= Ex-SPDT (EEX m II T6) |
| Options: |
0- Without |
1= Please List |
|
|
|
|
For assistance call 978-568-3400
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|