DS05 Flow Meter/Switch CLARK SOLUTIONS
DS05 Flow Meter/Switch
F.S. Ranges From 4 to 250 l/min water

DESCRIPTION
The flow meter and switch model DS05 works according to a modified variable area principle. The float is guided in a cylindrical measuring glass by means of a spring. The flowing medium moves the float in the flow direction. The upper edge of the float shows the momentary flow via an etched scale on the measuring glass.

A reed contact is mounted outside the meter in a sealed housing. When the float reaches the position of the reed contact the switch will close. With higher flows the float moves further upward until it reached a built-in float stop, still keeping the switch closed. This ensures a bistable switch function at any time. The reed contact is adjustable over the full switching range of the meter.

The built in spring and magnetic float are very reliable. As the spring opposes the float and the flow it is possible to mount the flow meter in any orientation.


SPECIFICATIONS
Max Pressure: 10 bar (145 PSIG)
Pressure Drop: 0.02-0.5 bar (0.3-7.2 PSI)
Max Temperature: 120°C (optionally 160°C)
  for liquids, 90°C for gases
Materials:
  Measuring Glass - Duran 50
  Housing - Aluminum
  Connections - Brass or Stainless
  O-rings -
              Brass Version - Buna
              SS Version - Viton
Electrical Connections - DIN 43650 plug
Accuracy - ±5% f.s.
Ranges:
  Water - 0.2-4.0 l/min to 30-250 l/min

APPLICATION
The variable area flow meter and switch model DS05 is used for measuring and monitoring the flow of low viscosity liquids and gases, i.e., in cooling loops of welding machines and laser systems, for pump monitoring, compressors and many other applications.


FEATURES

Small Mounting Dimensions

Brass or Stainless Steel Connections

Scales for Water and Air

High Switching Accuracy

Low Switching Hysteresis
CONTACTS
Function      
N/O: 250V 3A 100VA
SPDT:  250V 1.5A 50VA
*EX-N/O:  250V 2A 60 VA
*EX-SPDT:  250V 1A 30VA
*Per ATEX 100aEXII 2 G, EEx m II T6
DIMENSIONS
Model Dimensions in mm Weight (g)
SW D B G T L
DS05.1.x.x.x 32 43 67 1/4 NPT 14 132 625
DS05.2.x.x.x 32 43 67 1/2 NPT 15 135 625
DS05.2.x.x.05 32 43 67 1/2 NPT 15 163 650
DS05.3.x.x.06 32 43 67 3/4 NPT 18 167 850
DS05.3.x.x.07 41 50 70 3/4 NPT 18 152 1000
DS05.4.x.x.07 41 50 70 1.0 NPT 19 184 1000
DS05.4.x.x.08/09 41 50 70 1.0 NPT 19 184/200 1000
DS05.5.x.x.10 46 60 75 1-1/4 NPT 21 210 1400
DS05.5.X.X.11 46 55 73 1-1/4 NPT 21 222 1400
DS05
Electrical connection
ORDERING INFORMATION
Order Number Example DS0511N10311
Miniature variable area flow meter and switch
PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS
Connection: 1N= 1/4 “female NPT 2N= 1/2” female NPT 3N= 3/4” female NPT  4N= 1” female NPT 5N= 1 1/4 “ female NPT
Material: 1= brass with 301 stainless steel spring 2= all 316 stainless steel
Scale: 1= for water  
Measuring Ranges: Water
DS05.1 and DS05.2: 01= 0.2 - 4 l/min 02= 0.5 - 6 l/min 03= 0.5 - 8 l/min 04= 0.5 - 14 l/min
DS05.2 only: 05A= 2 - 22 l/min 05= 1-28 l/min    
DS05.3 only: 06= 2 - 45 l/min      
DS05.3 and DS05.4: 07= 2 -80 l/min 07A= 6-90 l/min    
DS05.4 only 08= 6-110 l/min      
DS05.5 only: 09= 15-150 l/min 10= 30 - 220 l/min Water 11= 35 - 250 l/min Water  
No. of contacts: 0= without contacts 1= 1 contact 2= 2 contacts  
Contact function: 1= N/O 2= SPDT 3S= Ex-N/O (EEX m II T6) 3U= Ex-SPDT (EEX m II T6)
Options: 0- Without 1= Please List    
For assistance call 978-568-3400