DS06 Flow Meter/Switch CLARK SOLUTIONS
DS06 Flow Meter/Switch for Water

F.S. Ranges From 4 to 250 l/min water

DESCRIPTION
The flow meter and switch model DS06 works according to a modified variable area principle. The float is guided in a cylindrical measuring tube by means of a slotted nozzle. The flowing medium moves the float in the flow direction. An externally mounted pointer indicator is magnetically coupled to the float. It follows the float position and indicates the flow rate on a scale.

A reed contact is mounted outside the meter in a sealed housing. When the float reaches the position of the reed contact the switch will close. With higher flows the float moves further upward until it reaches a built-in float stop, still keeping the switch closed. This ensures a bistable switch function at any time. The reed contact is adjustable over the full measuring range of the meter.

The built in spring and magnetic float are very reliable. As the spring opposes the float and the flow it is possible to mount the flow meter in any orientation.


SPECIFICATIONS
Max Pressure:
  Brass- 200 bar (2,900 PSIG)
  Stainless Steel - 300 bar (4,350
  PSIG)
Pressure Drop: 0.02-0.4 bar (0.3-5.8
  PSI)
Max Temperature: 100°C (160°C
  available as option)
Materials:
  Wetted Parts - Nickel plated brass
  or 316Ti SS1
  O-rings -
               Brass Version - Buna
              SS Version - Viton
Electrical Connections - DIN 43650
  plug
Accuracy - ±5% f.s.
Ranges:
  Water - 0.2-4.0 l/min to 30-250 l/min

DS06 Flow Switch (top) and DS06 Flow Meter/Switch
APPLICATION
The variable area flow meter and switch model DS06 is used for measuring and monitoring the flow of low viscosity liquids and gases, i.e., in cooling loops of welding machines and laser systems, for pump monitoring, compressors and many other applications.


FEATURES

Small Mounting Dimensions

Brass or Stainless Steel Connections

Scales for Water and Air

Universal Mounting Position

High Switching Accuracy

Low Switching Hysteresis
CONTACTS
Function      
N/O: 250V 3A 100VA
SPDT:  250V 1.5A 50VA
*EX-N/O:  250V 2A 60 VA
*EX-SPDT:  250V 1A 30VA
*Per ATEX 100aEXII 2 G, EEx m II T6
DIMENSIONS
Model Dimensions in mm Weight
with w/o
SW D D1 B G T L Indication
DS06.1.x.x.x 27 30 47 65 1/4 NPT 14 130 800 850
DS06.2.x.x.x 27 30 47 65 1/2 NPT 15 130 850 900
DS06.2.x.x.07/085 27 30 47 65 3/4 NPT 14 148 900 950
DS06.3.x.x.x 34 40 57 70 3/4 NPT 18 152 1400 1450
DS06.4.x.x.9-11 36 36 53 68 1.0 NPT 19 156 1100 1150
DS06.4.x.x.12 40 40 55 72 1.0 NPT 19 156 1100 1150
DS06.5.x.x.x 50 50 67 75 1-1/4 NPT 21 200 3000 3050
DS06.6.x.x.x 60 60 75 80 1-1/2 NPT 24 200 3800 3850
DS06 with indicator
Electrical Connection
ORDERING INFORMATION
Order Number Example DS061N1106112
Miniature variable area flow meter and switch
PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS
Connection: 1N= 1/4" female NPT 2N= 1/2" female NPT
3N= 3/4" female NPT 4N= 1" female NPT
5N= 1 1/4 “ female NPT 6N= 1 1/2" female NPT
Material: 1= brass with 301 stainless steel spring 2= all 316 stainless steel
Scale: 1= for water  
Measuring Ranges: Water
DS06.1 and DS06.2: 01= 0.2 -4 l/min 02= 0.4 -4.5 l/min
03= 0.6 -5 l/min  04= 0.5 -8 l/min
05= 1 -14 l/min 06= 1 -28 l/min
DS06.2 only: 07= 2 -40 l/min 08= 4 -55 l/min
DS06.3 and DS06.4: 09= 1 -70 l/min  10= 8 -90 l/min
11= 5 -110 l/min  
DS06.5 only: 12= 10 -150 l/min  
DS06.5 & DS06.6 only: 13= 35 -220 l/min  14= 35 -250 l/min
Version: 0= switch only, without flow rate indication 1= flow meter and switch, with side indicator
No. of contacts: 0= without contacts 1= 1 contact
2= 2 contacts  
Contact function: 1= N/O 2= SPDT
3S= Ex-N/O (EEX m II T6) 3U= Ex-SPDT (EEX m II T6)
For assistance call 978-568-3400

pumps | valves | instrumentation | new products | contact clark | site/product directory | enewsletter | home