DS15 Flow Indicator, Switch, Transmitter CLARK SOLUTIONS
DS15 Flow Indicator, Switch, Transmitter
F.S. Flow Ranges from 24 lph to 50,000 lph Water

DESCRIPTION
The model DS15 flow meters work according to the proven variable area principle. The float is moved upward in a tapered tube by the flowing medium and its upper edge indicates the flow rate by means of a scale affixed on to the measuring tube.

By using a float with an integrated magnet, optional alarm contacts or an analog output transducer may be added.

All flow meters have a male thread on the measuring tube and are supplied with two schedule 80 PVC-U pipe couplings. Please call for coupling materials other than PVC .

The variety of materials used and the simple to exchange measuring scales make these meters universally suitable for most liquid and gaseous media.

Applications are in the water treatment industry, wastewater, plating and surface finishing, chemical and food industries and many more.

SPECIFICATIONS
Measuring Tube Material - PVC-U transparent, Polyamide, Polysulfone
    or PVDF (for use with alarm contacts or analog output
    transducer only)
Float Material - PVDF, optionally st. steel AISI 304 and PVDF with
    integrated magnet
O-Rings - EPDM, Viton optional
Pipe Connections - PVC, optionally PP, PVDF
Max Pressure - 10 bar @ 20°C
Max Temperature Flow Tube Only -
    PVC: 60°C
    Polyamide: 75°C
    Polysulfone: 100°C
    PVDF: 110°C
Max Temperature with connectors made of:
    PVC: 60°C
    PP: 80°C Max
    PVDF:110°C
Mounting Position - vertically, flow from bottom to top
Mounting - with straight pipe, 5-7 x pipe dia. upstream and
    downstream of meter F
Measuring Accuracy - ±4% F.S.
Scales - water scales (in LPH) and air scales (in m^(3)/h) referenced
    to 0, 1, 2, or 3 bar above atmosphere and 20°C are standard.
    For other media, i.e. gases with higher pressures, HCL (30%),
    NaOH (30%) as well as other units of measurement
    (m^(3)/h, l/sec, GPM) special scales can be supplied.

Accessories
Alarm Contacts - bistable, N/C or N/O contact function on rising flow
    Mounting: adjustable on measuring tube
    Contact Rating: Max 220 VAC, 0.5A Max 10A/10VA
    Operating Temperature: 0...+55°C
    Hysteresis: 3 mm of float height
    Electrical Connection: Two wire, independent of polarity
Analog & RS-232 output -
    The optional analog output transducer is mounted onto the
    measuring tube of the DS15 flowmeter and registers the height of
    the float by means of an analog Hall sensor. The integrated
    electronics converts this signal to a 4-20 mA output. Additionally a
    digital value is available via an RS-232 interface.

    To utilize the analog output transducer, the standard float must
    be exchanged for a float with an integral magnet.

    The transducer is equipped with an EPROM which is programmed
    especially for the application. Therefore it is not possible to
    field adjust the transducers without consulting the manufacturer.

Electrical connection: 6-pin plug per DIN 45322 (included)
Wiring
Electrical Connection For RS-232
Interface- 9 Pin Sub-D-Connector
Transducer Sub-D-Connector
Pin 2 (GND) Pin 5 (GND)
Pin 5 (TxD) Pin 2 (RxD)
Pin 6 (RxD)  Pin 3 (TxD)
Data Format- 9600 baud, 8 data bits, 1 stop bit, no parity
Table 1: Measuring Ranges
Tube       Range Number Range l/h water Range Air m3/h Outlet Atmospheric Range Air m3/h Outlet 1bar Range Air m3/h Outlet 2 bar Range Air m3/h Outlet 3 bar
1 101 3-24 0.2-1 0.2-1.2 0.25-1.55 0.3-1.75
102 5-60 0.2-2.5 0.4-3.2 0.2-3.8 0.3-4.4
103 10-100 0.6-3.6 0.6-5.0  0.75-6.0 0.8-7.0
104 25-250 0.5-9.0 1.0-13.0 1.0-16.0 1.5-19.5
2 201 5-50 0.4-2.8 0.2-3.2 0.4-3.6 0.3-4.0
202 15-150 0.8-6.2 1.0-9.0 1.0-11.0 1.5-12.0
203 5-250 0.9-9.5 1.0-13.0 1.0-16.0 2.0-20.0
204 40-400 2.0-15.0 2.0-20.0 3.0-26.0 3.0-30.0
3 301 15-150 0.5-5.5 1.0-9.0 1.0-11.0 1.0-10.5
302 40-400 2.0-14.0 2.0-20.0 3.0-26.0 3.0-30.0
303 60-600 2.5-22.0 4.0-31.0 4.0-38.0 5.0-45.0
304 100-1000 4.0-34.0 5.0-45.0 6.0-58.0 7.5-67.5
4 401 25-250 1.0-8.0 1.5-13.0 1.5-16.0 1.5-19.5
402 40-400 2.0-14.0 2.0-20.0 3.0-26.0 3.0-30.0
403 100-1000 4.0-34.0 5.0-45.0 5.0-55.0 6.0-66.0
404 150-1500 5.0-50.0 6.0-70.0 7.5-86.0 7.5-98.0
5 501 15-150 0.7-5.0 1-7.5 1-9  1.6-10
502 60-600 2.5-20 3.5-28 4-35 5-40
503 100-1000 4-34 5-50 8-60 8-70
504 200-2000 8-70 12-90 10-120 15-130
505 300-3000 10-90 15-140 20-160 20-190
506 600-6000 22-190 30-260 40-380 40-400
507 1000-10000 35-300 50-420 60-510 70-600
508 2500-25000 80-720 115-1050 140-1240 166-1400
509 10000-50000 400-1500 500-2100 600-2500 700-2900
6 601 15-150 0.7-5.5 1-7.5  1-9 1.6-10
602 30-300 1-10 1.5-14 2-18 2.8-20
603 60-600 2.5-20 3.5-28 4-35 5-40
604 100-1000 4-34 5-50 8-60 8-70
605 150-1500 5-50 7.5-67 9.5-83 11-96
606 250-2500 8.5-76 10-115 14-131 17-152
607 400-4000 14-125 10-170 24-210 28-245
608 600-6000 22-190 30-260 40-380 40-400
609 1000-10000 35-300 50-420 60-510 70-600
610 1500-15000 50-500 80-700 85-760 102-880
611 2500-25000 80-720 115-1050 140-1240 166-1400
612 10000-50000 400-1500 500-2100 600-2500 700-2900
Note: Arbitrary scales and other units of measurement available on request
Conversion Factors

For GPH: Multiply l/h by 0.264

For GPM: Divide l/h by 227

For SCFH:  Multiply m³/h by 35.315

For SCFM:  Multiply m³/h by 0.5886

Measuring Tube 1...4
DIMENSIONS (MM)
Table 2: Dimensions
Tube      Range Number Flow Tube Male Thread (BSP) *PVC Pipe Adapter L L1 **d  **DN
1 101...104 3/4" 3/8" 165 171 16 10
2 201...204 1’ 1/2" 170 176 20 15
3 301...304 1 1/4" 3/4" 185 191 25 20
4 401...404 1 1/2" 1" 200 206 20 25
5 501...503 1 1/2" 1" 335 341 32 25
504...505
2 1/4" 1 1/2" 335 341 50 40
506...507 2 3/4" 2" 335 341 63 50
508...509 3 1/2" 2 1/2" 335 341 75 65
6 601...604 1 1/2" 1" 350 356 32 25
605...606 2" 1 1/4" 350 356 40 3
607...609 2 3/4" 2" 350 356 63 50
610...612 3 1/2" 2 1/2" 350 356 75 65
*Two schedule 80 PVC-U pipe adapters/couplings are included with each flowmeter. As the thread on the flowmeter body is metric, care in fitting selection must be taken if connectors other than the PVC connectors supplied are to be used.
**Dimension of metric pipe coupling which can be supplied in materials other than PVC. Please consult factory.


2 ea. Schedule 80 PVC -U pipe adapters/couplings are supplied with each flowmeter. The adapters are for pipe sizes according to table 2.



ORDERING INFORMATION
ORDER NUMBER ABCDEF
EXAMPLE: DS15-11101PVC100
Measuring Tube 5...6
PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS
A=Model B=Flow Tube Material C=Scale D=Range
Number
E=Process
Connections
F=Float Material
DS15 1=PVC-U (standard) 1= Water Select From Table 1 PVC= Schedule 80 1= PVDF (standard)
2= Polyamide 2=Air @ Atmos PVC pipe termination per Table 2 2= 304 SS
3=Polysulfone 3=Air@1 bar 3= PVDF with integrated magnet (for meters with alarm or analog outputs)
4=PVDF 4= Air@2 bar N= None
  5= Air@3 bar S= Special
9= Special Scale  
 
Options
00= none
11= 1 alarm contact (N.C.)
21= 2 alarm contacts (N.C.)
12= 1 alarm contact (N.O.)
22= 2alarm contacts (N.O.)
50= analog , 4..20 mA & RS232 output
For assistance call 978-568-3400