INSTRUMENTATION > FLOW > DS25 Flowmeter, Alarm & Analog Output (Including Totalizer)




DS25 Flowmeter, Alarm & Analog Output CLARK SOLUTIONS

DS25 Flowmeter, Alarm & Analog Output (Including Totalizer)

F.S. Ranges 0.01-570 gpm Liquid, 0.44-1100 scfm Gas

DESCRIPTION
Model DS25 flowmeters work according to the proven variable area principle. A float is guided in a conical measuring tube and is nearly independent of the viscosity of the medium. The flowing medium moves the float in the flow direction. An externally mounted pointer indicator is magnetically coupled to the float and thus, following the float position, indicates the flow rate on a scale.

This indicator assembly is equipped with a scale calibrated to the operating conditions in the system and additionally may contain alarm contacts and analog output including totalizer.

The variable area flowmeter model DS25 is used for measuring and monitoring the flow of all kinds of liquids or gases. By using only stainless steel AISI 316 Ti for the wetted parts, the meter is especially suited for aggressive media or for use in food and drink applications (with Tri-Clamp or other hygienic process connections).

FEATURES
- For Liquids & Gases
- Pressure to 320 bar (40 & 100 bar standard)
- Temperature to 400°C
- AISI 316 Ti Stainless Steel Construction
- Individually Calibrated
- Alarm & Analog Outputs Available

INDICATOR
The indicator part of the DS25 consists of an aluminum or polyamide housing with a pointer assembly magnetically coupled to the float.

The scale may be calibrated in flow units or in percent. Additionally, transmitters including totalizer and alarm contacts may be mounted in the indicator housing.

Ambient Temperature:
              PA housing: -25°C ... +100°C
              AL housing: -25°C ... +130°C
              (for higher or lower operating temperatures
              use option "temperature isolation (DS25.A)")

OPTIONS
Temperature isolation (DS25.A):
          For media temperatures outside the limits given
          in the technical specifications for the indicator
          assembly the measuring tube and the indicator
          assembly may be temperature isolated by
          mounting the indicator at a distance of 60 mm
          from the measuring tube. This ensures that the
          unit may be operated at media temperatures as
          high as stated in the specifications for the
          measuring tube.
Damping (DS25.D):
          Float damping is recommended for gas or steam
          applications to prevent erratic up and down
          movement of the float.
Oxygen Applications: For use with oxygen the meters
          may be supplied oil and grease-free.
Certificates: On request
Tags: Stainless steel tags with customer specified text
          are optionally available.

PNEUMATIC TRANSMITTER
on request
SPECIFICATIONS
TECHNICAL SPECIFICATIONS (MEASURING TUBE)
Measurable Media: liquids and gases
Ranges: see Tables 2 and 3
Turndown Ratio: 10:1
Accuracy:
              DS25.1: 1.6% f.s.
              DS25.2: 2.5% f.s.
Process Connections: see Table 1
Max. Pressure: see Table 1
Media Temperature:
              DS25.1: -180°C ... +400°C
              DS25.2: -80°C ... +130°C
              (the actual operating temperature also
              depends on the max. permissible temperatures
              for the indicator and the options utilized
              in the unit)
Materials:
              DS25.1: all wetted parts stainless steel AISI 316 Ti
              DS25.2: all wetted parts stainless steel AISI 316 Ti
              with PTFE coating
Mounting: Vertical
Flow Direction: from bottom to top
Mounting Length: see Table 1
Straight Pipe Run Recommended:
              1/2" to 2 1/2": none
              3" through 4": min 5 x diameter upstream
Electrical Protection: IP65

ALARM CONTACTS
Model: inductive proximity switch, SJ3.5-N per DIN
              19234 (NAMUR); or SPDT Relay
Rated Voltage: 8 VDC
Output Signal: <= 1 mA = in alarm state; >=3 mA = not in
              alarm state
Ambient Temperature: -25°C ... +100°C (for higher or lower
              operating temperatures use option "temperature
              isolation (DS25.A)")
Explosion Protection: ATEX100 EEx ia IIC T6
Recommended Accessories: KF Transformer isolated barrier
              with relay output (Converts NAMUR output to
              SPDT relay)

TRANSMITTER
Output Signal: 4 ... 20 mA
Indication: LCD display, 8 digits (programmable for indication
              of flow rate or as non-resettable totalizer)
Supply Voltage: see ordering information
Max. Load: 4-wire: >= 500 Ohm
2-wire: (Supply Voltage-13.5 V) ÷ 20 mA
Operating Temperature: 0 ... 100°C (for higher or lower
              operating temperatures use option "temperature
              isolation (DS25.A)")
Electrical Connection: Cable Gland or PG11

INTRINSICALLY SAFE TRANSMITTER
Technical specifications same as standard unit, except:
Output Signal: 4 ... 20 mA, 2-wire
Operating Temperature: -25°C ... +70°C (for higher
              or lower operating temperatures use option
              "temperature isolation (DS25.A)")
Explosion Protection: ATX100 EEx ia IIC T6
Recommended Accessories: intrinsically safe power
              supply (see "Options")

TRANSFORMER ISOLATED BARRIER W/RELAY OUTPUTS
Per DIN 19234 (NAMUR)
Model Power No. Channels Contact Rating
KFA5-SR2-EX2.W 103.5-126 VAC 2 AC:253V/2 DC: 40V/2A
KFD5-SR2-EX2.W 20-30 VDC 2 AC:253V/2A DC: 40V/2A
POWER SUPPLY FOR INTRINSICALLY SAFE TRANSMITTER
Output Signal: 0 / 4...20 mA, galvanically separated
Supply Voltage:
              SE11.2: 24 VAC / DC
              Max. Load: 750 Ohm
              Control Circuit: intrinsically safe [EEx ia] IIC
STEAM JACKETS
Steam jackets are used to keep the media in the measuring tube at a required temperature. Consult us for available configurations.
Table 1-Connection Chart
Nominal Bore mm(in.) Description Pressure Rating Tube No. Connection Code Length L(mm)
15 (1/2") Flanges ANSI 1/2" 150 lbs. 1 102 250
Flanges ANSI 1/2" 300 lbs. 1 103 250
1/2" NPT Female 580 PSI 1 105 295
Flanges ANSI 1/2" 150 lbs. 2 207 250
Flanges ANSI 1/2" 300 lbs. 2 208 250
1/2" NPT Female 580 PSI 2 210 295
20 (3/4") Flanges ANSI 3/4" 150 lbs. 1 112 250
Flanges ANSI 3/4" 300 lbs. 1 113 250
3/4" NPT Female 580 PSI 1 115 295
Flanges ANSI 3/4" 150 lbs. 2 217 250
Flanges ANSI 3/4" 300 lbs. 2 218 250
3/4" NPT Female 580 PSI 2 220 295
25 (1") Flanges ANSI 1" 150 lbs. 1 122 250
Flanges ANSI 1" 300 lbs. 1 123 250
Tri-Clamp DN25 / 1" 150 PSI 1 127 250
Flanges ANSI 1" 150 lbs. 2 229 250
Flanges ANSI 1" 300 lbs. 2 230 250
Tri-Clamp DN25 / 1" 150 PSI 2 234 250
Flanges ANSI 1" 150 lbs. 3 336 250
Flanges ANSI 1" 300 lbs. 3 337 250
1" NPT Female 580 PSI 3 339 310
32 (1 1/4") Tri-Clamp DN32 150 PSI 1 141 250
Flanges ANSI 1 1/4" 150 lbs. 2 243 250
Flanges ANSI 1 1/4" 300 lbs. 2 244 250
Tri-Clamp DN32 150 PSI 2 245 250
Flanges ANSI 1 1/4" 150 lbs. 3 347 250
Flanges ANSI 1 1/4" 300 lbs. 3 348 250
1 1/4" NPT Female 580 PSI 3 350 310
40 (1 1/2") Tri-Clamp DN40 / 1 1/2" 150 PSI 1 151 250
Tri-Clamp DN40 / 1 1/2" 150 PSI 2 252 250
Flanges ANSI 1 1/2" 150 lbs. 3 354 250
Flanges ANSI 1 1/2" 300 lbs. 3 355 250
50 (2") Flanges ANSI 2" 150 lbs. 3 357 250
Flanges ANSI 2" 300 lbs. 3 358 250
Tri-Clamp DN50 / 2" 150 PSI 3 360 250
Flanges ANSI 2" 150 lbs. 4 462 250
Flanges ANSI 2" 300 lbs. 4 463 250
2" NPT Female 580 PSI 4 465 325
2" NPT Female 580 PSI 4 468 325
80 (3") Tri-Clamp DN80 / 3" 150 PSI 4 470 300
Flanges ANSI 3" 150 lbs. 5 572 250
Flanges ANSI 3" 300 lbs. 5 573 260
100 (4") Tri-Clamp DN100 / 4" 150 PSI 5 575 250
Flanges ANSI 4" 150 lbs. 6 678 250
Flanges ANSI 4" 300 lbs. 6    
125 (5") Flanges ANSI 5" 150 lbs. 6    
Flanges ANSI 5" 300 lbs. 6    
150 (6") Flanges ANSI 6" 150 lbs. 6    
Flanges ANSI 6" 300 lbs. 6    
*not available with "steam jacket" option
Table 2 - Range Codes
Model DS25.1, Stainless Steel Version
Water @20°C
Tube No. Range Code Range (g/m) Pressure Drop (PSI) Max Viscosity (Centipoise)
w/o Recalibration
1 101 0.001-0.01 0.58 2,9
102 0.017-0.176 0.58 4,5
103 0.027-0.277 0.58 6,4
104 0.044-0.44 0.58 9,2
105 0.044-0.44 0.087 5,1
2 206 0.044-0.44 0.087 5,1
207 0.07-0.7  0.218 8,2
208 0.07-0.7  0.087 7,1
209 0.1-1.1 0.58 13
210 0.1-1.1 0.087 8,8
211 0.17-1.76 0.58 18
212 0.17-1.76 0.087 10
213 0.27-2.77 0.58 23
214 0.27-2.77 0.218 17
215 0.44-4.4 0.58 27
216 0.44-4.4 0.21 19
217 0.7-7.0 0.58 31
218 1-10.0  0.653 -
3 319 0.44-4.4  0.102 17
320 0.7-7.0  0.102 20
321 1.1-11.0 0.595 44
322 1.1-11.0 0.232 16
323 1.7-17.0 0.595 50
324 2.6-26.0  0.604 -
4 425 1.1-11.0 0.116 29
426 1.7-17.0 0.116 33
427 2.2-27.0 0.682 72
428 2.7-27.0 0.116 37
429 4.4-44.0 0.682 82
430 4.4-44.0 0.276 58
431 7.0-70.0 0.682 92
432 10-100 0.914 -
5 533 11-110 0.87 -
534 17-170 0.87 -
535 26-260 0.87 -
6 638 44-440  1.02 -
Air/Gases @20°C, 1.013 bar abs.
Tube No. Range Code Range (SCFM) Pressure Drop (PSI)  
1 101 0.044-0.44  0.653  
102 0.07-0.7 0.653  
103 0.1-1.0 0.653  
104 0.17-1.77 0.653  
2 206 0.32-3.2 0.29  
207 0.23-2.3  0.16  
208 0.38-3.8 0.16  
209 0.44-4.4 0.653  
210 0.59-5.9 0.16  
211 0.76-7.6 0.653  
212 0.94-9.4 0.16  
213 1.2-12 0.653  
214 1.5-15 0.16  
215 1.8-18 0.653  
216 2-20 0.29  
3 319 2.3-23 0.174  
320 2.9-29 0.319  
321 4.1-41 0.194  
322 5.3-53 0.319  
323 7.7-77 0.682  
4 425 5.9-59 0.203  
426 7.7-77 0.363  
427 9.4-94 0.203  
428 12-118 0.363  
429 12-118 0.783  
430 17-170 0.203  
431 21-210 0.363  
432 29-290 0.783  
5 533 29-290 0.435  
534 44-440  0.943  
535 50-500 0.435  
536 70-700 0.943  
537 110-1100 0.943  
Table 3 - Range Codes
Model DS25.2, PTFE Coated
Water @20°C
Tube No. Range Code Range (g/m) Pressure Drop (PSI)
2 250 .044-0.44 0.232
251 0.07-0.7 0.232
252 0.1-1.1 0.232
253 0.17-1.76 0.232
254 0.27-2.77 0.232
255 0.44-4.4 0.261
3 356 0.7-7.0 0.290
357 1.1-11.0 0.290
358 1.7-17.0 0.319
4 459 1.7-17.0 0.290
460 2.2-27.0 0.290
461 4.4-44.0 0.290
462 7.0-70.0 0.319
5 563 7.0-70.0 0.363
564 11-110 0.363
565 17-170 0.363
6 666 28-280 0.435
Air/Gases @20°C, 1.013 bar abs.
Tube No. Range Code Range (SCFM) Pressure Drop (PSI)
2 250 0.2-2.0 0.29
251 0.3-3.0 0.29
252 0.5-5.0 0.29
253 0.76-7.6 0.29
254 1.2-12 0.29
255 2-20 0.319
3 356 2.9-29 0.363
357 5-50 0.363
4 459 8-80 0.363
460 12-120 0.363
461 21-210 0.363
5 563 29-290 0.174
564 52-520 0.319
FR2000 Flowmeter Diagram
FR2000 Flowmeter Diagram
Meas. Tube H1(mm) H2(mm) Wt(kg)
1 122 122 5
2 123 127 5
3 131 136 6.5
4 147 152 11
5 161 168 16
6 170 176 20
FR2000 Flowmeter Diagram
ORDERING INFORMATION
Order Number ABCDEFGHIJ
Example:  DS25-1105110410000CG
PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS
A=Model B=Material Version C=Process Connection D=Medium E=Measuring Range F=Indicator Housing G=Alarm contacts H=Analog Output I=Supply Voltage J=Electrical Connection
DS25 1 = stainless steel 101...678 = according to Table 1 1 = water / liquid 101...666 = according to range code  tables 2&3 1= Polyamide 0= without   0= without 00= without CG=Cable Gland
2 = wetted parts PTFE coated 999 = special connection 2 = air/ gases 999 =special range 2= Aluminum 1= 1 min contact 1S= 1 min contact, SPDT, w/ SE01.3 1= transmitter 02= 110 VAC, 4-20 mA, 4-wire PG11=PG11
          2= 1 max contact 2S= 1 max. contact, SPDT, w/ SE01.3 2= transmitter, intrinsically safe 03= 230 VAC, 4-20 mA, 4-wire  
3= 1 min/1 max contact 3S= 1 min/ 1 max contact, 2 xSPDT, w/ SE01.4 3= pneumatic transmitter 06= 24 VAC, 4-20 mA, 4-wire
4= 2 min contacts 4S= 2 min. contacts, 2 xSPDT, w/SE01.4   08= 24 VDC, 4-20 mA, 2-wire
5= 2 max contacts 5S= 2 max contacts, 2 xSPDT, w/ SE01.4 13= 3-15 psi
 
Options
Please indicate in writing
Further Ordering Information
Important: for complete identification of the meter the following information must be specified:
1 Order no. according to table above
2 Identify desired units of flow
3 Identify medium
4 Temperature (operational, max.)
5 Pressure (operational, max.)
6 Viscosity (for liquids only)
7 Specific gravity of medium
8 For gases only: reference conditions
9 Any additional application specific information