Ahlborn FDA-Series Pressure Sensors ALMEMO Ready DESCRIPTION |
FDA602S1K/S6K/S2K/612SR Differential Pressure Sensor with ALMEMO connector. For air flow measurement, the FDA602S1K/56K may be used with a pitot tube and calibrated to indicate velocity and differential.
FDA612SA barometric pressure sensor made highly accurate through piezo-resistive pressure sensor. |
|||||||||||||||||||||||||||||
| SPECIFICATIONS FDA602 - DIFFERENTIAL PRESSURE Measuring Range: FDA602-S1K: ±1250 Pa (5"w.c.), 1-40 m/s. FDA602-S6K: ±6800 Pa (27.3"w.c.), 2-90 m/s FDA602-M6: ±6800 Pa (27.3"w.c.) FDA612-MR: ±1000 mbar (14.5 PSIG) Accuracy: ±0.5% F.S. (0.2% typ.) Nominal Temperature: 22ºC ±2ºC Temperature Drift: 1.5%(0.5% typical) F.S. max. Position Sensitivity (FDA602M6 only): ±0.02"w.c. Max. Static Pressure: 3 bar (43.5 PSIG) Max. Differential Pressure: 3 x meas. range Operating Range: -10 +60ºC, 10 90% RH non-condensing Dimensions: 37 x 36 x 22mm Sensor Material: aluminum, nylon, silicone, silica gel, brass Hose Connections: for 3/16" ID flexible tubing FDA612SA - BAROMETRIC PRESSURE Measuring Range: 700…1050 mbar (20.7…31.0"Hg)Accuracy: ±0.5% F.S. (0.1% typ.) Nominal Temperature: 25ºC Temperature Drift: < ±1% of final value Max. Pressure: 2 x meas. range Operating Range: -10…+60°C, 10…90% RH non-condensing Dimensions: 90 x 20 x 7.6 mm Sensor Material: aluminum, nylon, silicone, silica gel, brass Hose Connections: Ø 5mm, 12mm long |
||||||||||||||||||||||||||||||
| ORDERING INFORMATION |
||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
| These products are for use with our portable, bench-top and rack mount meters and data loggers. Refer to our data logger data sheets for further application information or give us a call. |
||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
|
||||||||||||||||||