Model 2200 Programmable Batch Controller CLARK SOLUTIONS
Model 2200 Programmable Batch Controller
Pulse Inputs, Pulse & Relay Outputs

DESCRIPTION

The Series 2200 is a full featured, programmable batch controller. The flexibility of the 2200 allows it to be used in a wide variety of fluid batching and blending operations that require volumetric or time based measurement. The front panel mounted keypad is used for programming, setting the batch parameters and operation. The two control relays may be programmed to operate one or two stage batch operations. While one relay provides the primary batch function, the other may be used as a prewarn, overrun signal or missing signal alarm. This second relay may also be used as a high or low flow alarm independent of the batching function. The START, STOP and RESET functions may also be duplicated for remote operation with the addition of an accessory card.

The two line X sixteen character alphanumeric display may be configured by the user to simultaneously display any two of the following: Flow Rate, Flow Total, Batch Status or Batch Count. The Batch Status mode may be programmed to count up or down, in either units of measure or percentage of batch. LEDs are used to indicate batching relay status.

The Series 2200 will measure a single batch, a preset number of batches or will batch continuously with a programmable time delay between batches. The "End of Batch" signal from one unit may be used to start another. Enabling the Automatic Overrun Compensation feature allows the 2200 to adjust the end of the batch based on the overrun of the previous batch.

The panel meter conforms to DIN Standard dimensions, 192 mm X 96 mm, for meter sizes and panel cutouts. The 2200 is also available in NEMA 4 and NEMA 4X wall mount versions.

The Series 2200 may be calibrated in the field. All flow sensors with a digital pulse, sine wave or analog sensors, including non-linear and logarithmic signals may be used. Up to twelve separate calibration points may be entered for linearization.

Programming is menu driven and all data is entered using five front panel mounted keys. A software lock allows the user to enter a password to prevent changing the totals, calibration or control settings. Programming flexibility is extended to the measurement units. The Series 2200 software contains nineteen rate of flow units and seven total flow units. There is also the provision for adding custom units for each. Also written into the software is a self-diagnostic program that assists the operator in troubleshooting any problems.

The 2200 also provides a standard pulse output to interface with other batch controllers or external data collection devices that accept a pulse or dry contact closure. The resolution of the TTL compatible signal may be programmed from the front keypad. All calibration information, units of measure, batch sizes and flow totals are stored in a non-volatile memory that does not require battery back-up for data storage.

A Model 2201 dual batch unit is available. This option allows two batch operations from a single unit. These can be volumetric batches from two flow streams using an optional input card, or time based. The dual batch version is equipped with four control relays.  The 2200 is expandable with a long list of options to custom tailor the unit for individual requirements.

These options include:

  • Second batch channel- converts the 2200 to a dual batch device.
  • Display backlighting- with variable contrast for low light situations.
  • Power supplies - 12 VDC, 12-36 VDC, 24 VAC, 115 VAC or 230 VAC.
  • Mechanical counters - built-in, non-resettable seven digit mechanical counters.
  • Control relays - C Form mechanical relays, two additional available, independently
       programmed from the keypad by rate for alarms orÊÊÊ pump control; or by
       total for counting and proportioning.
  • Analog output - isolated 4-20 mA, 0 to 5 Volt or 0 to 10 Volt outputs, programmed
       from the keypad.
  • Analog input - to accept inputs from other flow devices with analog outputs.
  • RS232/485 port- allows two way serial communication with the 2200.

Power Supply Options:10-26 VAC/12-36 VDC (24 VAC/12-36 VDC option),
    or 115/230 VAC, 50/60 Hz (115/230 VAC option),
    or 10.6-16 VDC (12 VDC option)
Power Consumption: 8.5 Watts maximum
Display: two lines X 16 characters, alphanumeric, dot matrix LCD display with variable
   contrast. Large 0.32" character height. STN (Super-Twisted Nematic) display type with
   +/- 20 degree viewing angle, optional backlighting
Weight: 3 pounds maximum (panel mount with DIN draw mounting brackets), 9.2
   pounds maximum wall mount
Operating Temperature: +32°F to +158°F (0°C to +70°C)
Storage Temperature: -40°F to +185°F (-40°C to +85°C)
Dimensions:
   Panel Mount: 7.56"W x 3.78"H x 4.625"D
   Wall Mount: 10.997"W x 9.5"H x 5.784"D
Sensor Input: digital pulse input
Input Impedance: 14 kOhms
Signal Amplitudes: 3 to 15 VDC (high) open or 0 to 1 VDC (low)
Frequency Input Range: 0 to 10 kHz
Sensor Calibration: 12 point linearization with 7 digit floating point “K” Factor and
   frequency table entries

UNITS OF MEASURE:
Flow rate: 19 standard, 1 custom programmable, custom flow rate unit: 7 character
   label 7 digit floating point conversion from gallons/minute to custom unit
Flow total: 7 standard, 1 custom programmable, custom flow total unit: 4 character
   label 7 digit floating point conversion from gallons to custom unit
Totalizer: 
   Range: 0 to 1,000,000,000 (i.e. 0 to 1,000,000,000 gallons, 0 to 1,000,000,000
      liters, etc.)
Data Update Rate: adjustable 0.5 seconds to 5.0 seconds in 0.5 second increments,
   adjustable averaging function for smoothing erratic flow rates
Pulse Output: Open collector transistor pulse in any standard or custom flow total units,
   adjustable 25 mS to 5.0 second pulse output width in 25 mS increments, Maximum
   sinking current: 300 mA @ 36 VDC
Batch Relay Output: SPDT contacts, 6.0 amps @ 250 VAC or 30 VDC maximum resistive
   load, user configured as batch relay, pre-warn, or overrun relay, coil energizes at
   "start" and de-energizes at "stop" or end of batch function
Relay Option: 2 optional relays-single batch unit only, SPDT contacts, 6.0 amps @ 250
   VAC or 30 VDC maximum resistive load, user configurable as totalizer, high rate alarm,
   or low rate alarm, adjustable 0 to 120 second delay (in 0.5 second increments) until 
   activation for alarm functions, 0 to 50% (of set point) hysteresis for alarm functions
Totalizer Option: Two 7 digit, non-resettable electromechanical counters, user
   configurable output in any standard or flow total units or number of batches

ORDERING INFORMATION
ORDER NUMBER ABCDEFGHIJ
EXAMPLE: 22-010111C01
PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS
A=MODEL B=MONITORING CAPABILITY C=CHANNEL MONITORING D=CARD OPTION 1 E=CARD OPTION 2 F=CARD OPTION 3 G=OPTIONS - RELAY SINGLE CHANNEL ONLY H=INPUT VOLTAGE / BACKLIGHTING I=COUNTER J=MOUNTING
22 0=Standard 0=Single Channel 0=No Option 0=No Option 0=No Option 1=No Added Relays A=12 VDC-Only without LCD Illumination 0=No Mechanical Counter 0=Panel Mount, NEMA 4X Front Panel
1=12 Point Linearization 1=Dual Channel 1=Remote Batch Card 1=Analog Output 1=Analog Output 1 2=2 Additional Relays B=24 VAC/12-36 VDC without LCD Illumination 1=One Mechanical Counter 1=Wall Mount, NEMA 4-Hinged Metal Enclosure
      2=Analog Input 1=Analog Output 2   C=115 VAC without LCD Illumination 2=2 Mechanical Counters 2=Wall Mount, NEMA 4X-Molded Case
3=Digital/Sine Wave Input-10 VDC Excitation 3=Digital/Sine Wave Input-10 VDC Excitation D=230 VAC without LCD Illumination   3=Wall Mount, NEMA 4X-Hinged Polymer Enclosure
4=Digital/Sine Wave Input-24 VDC Excitation 4=Digital/Sine Wave Input-24 VDC Excitation E=12 VDC-Only with LCD Illumination  
5=RS-232 Serial Communications Output 5=RS-232 Serial Communications Output F=24 VAC/12-36 VDC with LCD Illumination
6=RS-485 Serial Communications Output   G=115 VAC with LCD Illumination
  H=230 VAC with LCD Illumination