ALMEMO input connection plugs provide the ultimate versatility in connecting almost any sensor to an ALMEMO instrument. The connection plugs are available for a broad range of sensor inputs, including thermocouple, RTD, and thermistor. Additionally, “blank” plugs are available to measure various electrical sensor output signals, including DC and AC volts and millivolts, current, and resistance. Frequencies as high as 25KHz and pulses with frequencies as high as 65,000 per minute may also be connected. The blank plugs allow the user to store the sensor-specific parameters, e.g. zero, gain, and engineering unit designation, in an EEPROM in the ALMEMO connection plug.Zero and gain calibration adjustments to any attached sensor may be made through the microprocessor-based ALMEMO interface, and the adjustments are stored in non-volatile memory onboard the sensor’s plug.

A supply voltage of 6-12 VDC is available from an ALMEMO plug (depending on the specific ALMEMO device).


Almemo Plug

Get a printer friendly Acrobat™ file for each of the following:
Type of Sensor Model Measuring Range *Unit Resolution Linearization Accuracy Connection Plug
Resistance−based temperature sensors:
Pt100/1000−1 4−conductor FP Axxx
(See more...)
-200.0 … +850.0 °C 0.1 K ±0.05 K ±0.05 % of meas.v. ZA 9030−FS1 / 4
Pt100/1000−2 4−conductor FP Axxx
(See more...)
-200.00 … +400.00* °C 0.01 K ±0.05 K ZA 9030−FS2 / 5
Pt100−3 4−conductor FP Axxx
(See more...)
0.00 … +65.00* °C 0.001 K ±0.005 K ZA 9030−FS7
Ni100/1000 4−conductor   -60.00 … +240.00 °C 0.1 K ±0.05 K ZA 9030−FS3 / 6
Ntc type N FN Axxx -50.00 … +125.00 °C 0.01 K ±0.05 K ZA 9040−FS
Thermocouples:
NiCr−Ni (K) FT Axxx
(See more...)
-200.0 … +1370.0 °C 0.1 K ±0.05 K ±0.05 % of meas.v. ZA 9020−FS
NiCroSil−Nisil (N)   -200.0 … +1300.0 °C 0.1 K ±0.05 K ±0.05 % of meas.v. ZA 9020−FSN
Fe−CuNi (L)   -200.0 … +900.0 °C 0.1 K ±0.05 K ±0.05 % of meas.v. ZA 9021−FSL
Fe−CuNi (J)   -200.0 … +1000.0 °C 0.1 K ±0.05 K ±0.05 % of meas.v. ZA 9021−FSJ
Cu−CuNi (U)   -200.0 … +600.0 °C 0.1 K ±0.05 K ±0.05 % of meas.v. ZA 9000−FSU
Cu−CuNi (T)   -200.0 … +400.0 °C 0.1 K ±0.05 K ±0.05 % of meas.v. ZA 9021−FST
PtRh10−Pt (S)   0.0 … +1760.0 °C .1 K ±0.3 K ZA 9000−FSS
PtRh13−Pt (R)   0.0 … +1760.0 °C 0.1 K ±0.3 K ZA 9000−FSR
PtRh30−PtRh6 (B)   +400.0 …+1800.0 °C 0.1 K ±0.3 K ZA 9000−FSB
AuFe−Cr   -270.0 … +60.0 °C 0.1 K ±0.1 K ZA 9000−FSA
Electrical and digital signals:
Millivolt DC   -10.0 … +55.0 mV 1 µV ZA 9000−FS0
Millivolt 1 DC   -26.0 … +26.0 mV 1 µV ZA 9000−FS1
Millivolt 2 DC   -260.0 … +260.0 mV 0.01 mV ZA 9000−FS2
Volt DC   -2.6 … +2.6* V 0.1 mV ZA 9000−FS3
Volt DC   -26 … +26 V 1 mV ZA 9602−FS
for measuring bridges, supply 5V (example)   −26.0 ... +26.0 mV 1 µV ZA9650FS1V
for potentiometer, supply 2.5V   −2.6 ... +2.6* V 0.1mV ZA9025FS3
Volt AC (50Hz…2kHz) (example)   0 … +26 V 0.1 V ZA 9603−AK3
Volt AC (11Hz…250Hz) (example)   0 … +400 V 1 V ZA 9903−AB5
Ampere AC (11Hz…250Hz) (example)   0 … +10.00 A 0.01 A ZA 9904−AB2
Volt DC (sampling rate 1kHz) (example)   0 … +400 V 1 V ZA 9900−AB5
Ampere DC (sampling rate 1kHz) (example)   0 … +10.00 A 0.01 A ZA 9901−AB4
Milliampere DC   -32.0 … +32.0 mA 1 µA ZA 9601−FS1
Percent (4−20mA DC)   0.0 … 100.0 % 0.01 %   ZA 9601−FS2
Ohm   0.00 … 500.00* Ohm 0.01 Ohm ZA 9003−FS
Ohm   0.0 … 5000.0* Ohm 0.1 Ohm ZA 9003−FS2
Frequency   0 … 15000 Hz 1 Hz ZA 9909−AK1U
Pulses/measuring cycle   0 … 65000     ZA 9909−AK2U
Digital interface   0 … 65000     ZA 9919−AKxx
Digital input   0.00…100.00 %   ZA 9000−ES2
Infrared sensors:
Infrared 1 FI A628−1/5xSS 0.0 … +200.0 °C 0.1 K ±0.05 K ±0.05 % of meas.v.  
Infrared 4 FI A628−4xSS –30.0 … +100.0 °C 0.1 K ±0.05 K  
Infrared 6 FI A628−6xSS 0.0 … +500.0 °C 0.1 K ±0.1 K ±0.05 % of meas.v.  
Capacitive humidity sensors:
Relative humidity FH A646
(See more...)
5.0 … 98.0 %H 0.1 %  
Relative humidity with TC FH A646−R
(See more...)
5.0 … 98.0 %H 0.1 % ±0.5 %  
Dew point temperature   -25.0 … 100.0 °C 0.1 K ±0.2 K  
Mixture ratio   0.0 … 500.0 g/kg 0.1 g/kg ±0.5 % of meas.v.  
Partial vapor pressure   0.0 … 1013.2 mbar 0.1 mbar ±0.1mbar ±0.1 % of meas.v.  
Enthalpy   0.0 … 400.0 kJ/kg 0.1 kJ/kg ±0.5 % of meas.v.  
Psychrometer FN A846
(See more...)
        ZA 9846−AK
Humid temperature   0.00 …+100.00 °C 0.01 K ±0.05 K  
Relative humidity   0.0 … 100.0 %H 0.1 % ±1.0 %H  
Dew point temperature   -25.0 … 100.0 °C 0.1 K ±0.2 K  
Mixture ratio   0.0 … 500.0 g/kg 0.1 g/kg ±0.5% of meas.v.  
Partial vapor pressure   0.0 … 1013.2 mbar 0.1 mbar ±0.1mbar ±0.1% of meas.v.  
Enthalpy   0.0 … 400.0 kJ/kg 0.1 kJ/kg ±0.5% of meas.v.  
Flow sensors:
Rotating vane, normal FV A915−S120
(See more...)
0.30 … 20.00 m/s 0.01 m/s ±0.1 m/s ±0.2% of meas.v. ZA 9915−AKS1
Rotating vane, normal FV A915−S140
(See more...)
0.40 … 40.00 m/s 0.01 m/s ±0.2 m/s ±0.2% of meas.v. ZA 9915−AKS2
Rotating vane, micro FV A915−S220
(See more...)
0.50 … 20.00 m/s 0.01 m/s ±0.1 m/s ±0.2% of meas.v. ZA 9915−AKS3
Rotating vane, micro FV A915−S240
(See more...)
0.60 … 40.00 m/s 0.01 m/s ±0.2 m/s ±0.2% of meas.v. ZA 9915−AKS4
Rotating vane, macro FV A915−MA1
(See more...)
0.10 … 20.00 m/s 0.01 m/s ±0.1 m/s ±0.2% of meas.v. ZA 9915−AK5
Water turbine FV A915−WM 0.00 … 5.00 m/s 0.01 m/s ±0.1 m/s ±0.2% of meas.v. ZA 9915−AK6
Dyn. pressure sensor FD A602−S1K
(See more...)
0.5 … 40.0 m/s 0.1 m/s ±0.1 m/s  
Dyn. pressure sensor FD A602−S6
(See more...)
1.8 … 90.0 m/s 0.1 m/s ±0.1 m/s  
Thermoanemometer FV A935−TH
(See more...)
4 0 … 2.000 m/s 0 .001 m/s  
Thermoanemometer FV A9355−TH3
(See more...)
0 … 20.00 m/s 0.01 m/s  
Thermoanemometer FV A605−TA1 0.01 … 1.000 m/s 0.001 m/s  
Thermoanemometer FV A605−TA5 0.15 … 5.00 m/s 0.01 m/s  
Chemical probes:
Conductivity FY A641−LF 0.0...20.000 mS 0.001 mS ±0.2% of meas.v.  
O2 dissolved, saturation FY A640−O2 0 … 260 % 1%  
O2dissolved, concentration FY A640−O2 0.0 … 40.0 mg/l 0.1 mg/l ±0.2 mg/l  
O2 in gases Y 9600−O2 1 … 100 % 1%  
O3 in gases FY 9600−O3 0 … 300 ppb 20 ppb  
CO probe FY A600−CO
(See more...)
(e.g.) 0 … 300 ppm 1 ppm  
CO2 in gases FY A600−CO2
(See more...)
(e.g.)0.000… 0.500 % 0.01 % ±0.2 % of meas.v.  
pH−probe FY 96PH−Ex 0.0 … 14.00 pH 0.01 pH ZA 9610−AKY4
Redox probe FY 96RX−Ex 0.0 … 2600.0 mV 0.1 mV ZA 9610−AKY5
Optical radiation (examples):
Lux measuring probe FL A613−VL 0 … 260000 lux 1 lux  
Lux measuring probe FL A603−VL2 0.05 … 12500 lux 0.01 lux  
Lux measuring probe FL A603−VL4 1 … 250000 lux 1 lux  
UV measuring probe FL A613−UV 0 … 87.00 W/m2 0.01 W/m2  
UVA measuring probe FL A603−UV24 0.00004 … 100 mW/cm2 0.1 µW/cm2  
Radiometric meas. head FL A603−RW4 0.00004 … 10 mW/cm2 0.01 µW/cm2  
Photosynthesis meas. head FL A603−PS2 0.00001 … 2.5 µmol/m2*s 10 pmol/m2*s  
Further transducers that can be connected (examples):
Heat flow plates FQ Axxx -260.0 … +260.0 mV 0.01 mV ZA 9007−FS
Moisture sensor for materials H A696−MF 0 … 50.0 % 0.1%  
Differential pressure FD A612−SR 0 … 1000 mbar 0.1 mbar  
Barometer FD A612−SA 0.0 … 1050 mbar 0.1 mbar  
Pressure transducers FD−A602xx (e.g.) 0.00 … 10.00 bar 0.01 bar  
Force transducer FK Axxx (e.g.) 0.0 … 50.00 kN 0.01 kN  
Displacement transducers FW Axxx (e.g.) 0.0 … 150.00 mm 0.01 mm  
Tachometer FU A919−2 8 … 30000 rpm 1 rpm   ZA 9909−AK4U
Function values:
Difference          
Max. value          
Minimum value          
Average value over time          
Average value over meas. pt.          
Sum over measuring points   0 … 65000      
Total number of pulses ZA 9909−AK2U 0 … 65000      
Pulses/print cycle ZA 9909−AK2U 0 … 65000      
Alarm value   0.0 … 100.00 %    
Thermal coefficient M (q) / M (?T)          
Wet bulb globe temp. (0.1TT+0.7HT+0.2GT)          
Measuring value:
Cold junction temperature     °C    
Number of average values          
Volume flow   m3/h   0 ... 65000 m3/h      
* Data may vary depending on device; (see data sheet per device).


For your convenience, the following ALMEMO interface/connection plugs can be purchased online for connection of customer supplied temperature probes to AMR dataloggers. Also available are interface connectors for measurement of current, voltage and frequency. Please call Clark to discuss specific sensor requirements so we can be sure to supply the correct product for your application. Refer to the ALMEMO Manual (see pdf link on this page) for complete technical details.

ORDERING INFORMATION
FOR YOUR CONVENIENCE, THESE ITEMS ARE AVAILABLE ONLINE
ZA9000-FS2
ZA9000-FS3
ZA9020-FS
ZA9021-FSJ
ZA9021-FST
ZA9030-FS1
ZA9030-FS2
ZA9601-FS2
ZA9601-FSV12
ZA9602-FS
ZA9909-AK4U

Qty:

Show Discount Schedule


For assistance call 978-568-3400

pumps | valves | instrumentation | new products | contact clark | site/product directory | enewsletter | home