| Clark Solutions 120 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Explosion Proof, Adjustable Ranges 30" Vac to 6000 PSI, -180°F to 650°F (Page 3 of 9)
|
||||||||||||||
| Range/Material Code | Adjustable Set Point Range High end of range on rise, low end on fall | Deadband | *Over Range Pressure | **Proof Pressure | ||||
|
psi Unless noted |
bar |
psi Unless noted |
bar |
psi |
bar |
psi |
bar |
|
|
Brass bellows with 1/4" NPT (female) nickel-plated brass pressure connection; Models 126 & 134 have zinc-plated steel spring exposed to media |
||||||||
|
126 |
30 to 3" Hg Vac |
-1 to 0.1 |
0.2" to 0.6" Hg |
0.01 to 0.02 |
80"wc |
0.2 |
5 |
0.3 |
|
134 |
30" Hg Vac to 20 psi |
-1 to 1.4 |
0.2" to 6" Hg |
0.01 to 0.02 |
20 |
1.4 |
25 |
1.7 |
|
137 |
15 to 80"wc |
0.04 to 0.19 |
2 to 6"wc |
0.01 to 0.02 |
80"wc |
0.2 |
5 |
0.3 |
|
144 |
0.5 to 20 |
0.04 to 1.4 |
0.1 to 0.3 |
0.01 to 0.02 |
20 |
1.4 |
25 |
1.7 |
|
152 |
1 to 50 |
0.07 to 3.4 |
0.1 to 0.5 |
0.01 to 0.03 |
50 |
3.4 |
75 |
5.2 |
|
156 |
2 to 100 |
0.14 to 6.9 |
0.2 to 0.6 |
0.01 to 0.04 |
100 |
6.9 |
125 |
8.6 |
|
164 |
4 to 200 |
0.3 to 13.8 |
0.2 to 1 |
0.01 to 0.01 |
200 |
13.8 |
200 |
13.8 |
|
Phosphor bronze bellows with 1/4" NPT (female) nickel-plated brass pressure connection |
||||||||
|
270 |
4 to 200 |
0.3 to 13.8 |
1 to 4 |
0.07 to 0.3 |
200 |
13.8 |
250 |
17.2 |
|
274 |
6 to 300 |
0.4 to 20.7 |
1 to 5 |
0.07 to 0.3 |
300 |
20.7 |
350 |
24.1 |
|
Welded 316L stainless steel bellows and 1/4" NPT (female) pressure connection |
||||||||
|
356 |
15 to 100 |
1.0 to 6.9 |
0.7 to 1.8 |
0.05 to 0.1 |
100 |
6.9 |
800 |
55.2 |
|
358 |
15 to 200 |
1.0 to 13.8 |
1 to 3 |
0.07 to 0.2 |
200 |
13.8 |
800 |
55.2 |
|
361 |
20 to 300 |
1.4 to 20.7 |
1 to 4 |
0.07 to 0.3 |
300 |
20.7 |
800 |
55.2 |
|
376 |
25 to 500 |
1.7 to 34.5 |
1.5 to 5 |
0.1 to 0.3 |
500 |
34.5 |
800 |
55.2 |
|
303 stainless steel piston and Buna-N O-Ring with 1/4" (female) pressure connection ( not recommended for gas service since drying of the O-Ring seal can allow bleeding of medium into the atmosphere) |
||||||||
|
612 |
125 to 3,000 |
8.6 to 206.8 |
40 to 250 |
2.8 to 17.2 |
6,000 |
413.7 |
10,000 |
689.5 |
|
616 |
700 to 5000 |
48.3 to 344.7 |
40 to 375 |
2.8 to 25.9 |
6,000 |
413.7 |
10,000 |
689.5 |
|
316 stainless steel bellows and 1/4" NPT (female) pressure connection (not recommended for rapid or high cycling pressure changes) |
||||||||
|
680 |
100 to 1700 |
6.9 to 117.2 |
9 to 40 |
0.6 to 2.8 |
1700 |
117.2 |
2500 |
172.4 |
|
Buna-N diaphragm and O-Ring with 1/4" NPT (female) nickel-plated brass pressure connection; Optional Viton® diaphragm & O-Ring available for code 704-705 |
||||||||
|
701 |
1.5 to 30 |
0.1 to 2.1 |
1 to 2 |
0.07 to 0.14 |
500 |
34.5 |
1000 |
68.9 |
|
702 |
3 to 100 |
0.2 to 6.9 |
1 to 4 |
0.07 to 0.3 |
500 |
34.5 |
1000 |
68.9 |
|
703 |
9 to 300 |
0.6 to 20.7 |
1 to 5 |
0.07 to 0.3 |
500 |
34.5 |
1000 |
68.9 |
|
704 |
15 to 500 |
1.0 to 34.5 |
2 to 8 |
0.14 to 0.6 |
1500 |
103.4 |
2500 |
172.4 |
|
705 |
30 to 1000 |
2.1 to 68.9 |
3 to 20 |
0.21 to 1.4 |
1500 |
103.4 |
2500 |
172.4 |
|
Buna-N diaphragm and O-Ring with 1/4" NPT (female) aluminum pressure connection and cap |
||||||||
|
450 |
30" to 3" Hg Vac |
-1.0 to -0.1 |
0.1 to 0.3"Hg |
0.003 to 0.1 |
80"wc |
0.2 |
225 |
15.5 |
|
451 |
2 to 80"wc |
0.005 to 0.2 |
0.8 to 2"wc |
0.002 to 0.005 |
80"wc |
0.2 |
225 |
15.5 |
|
452 |
30" Hg Vac to 20 psi |
-1 to 1.4 |
0.1 to 0.4" Hg |
0.003 to 0.01 |
20 |
1.4 |
225 |
15.5 |
|
453 |
0.5 to 20 |
0.03 to 1.4 |
0.05 to 0.1 |
0.003 to 0.01 |
20 |
1.4 |
225 |
15.5 |
|
454 |
0.8 to 30 |
0.06 to 2.1 |
0.05 to 0.2 |
0.003 to 0.014 |
30 |
2.1 |
225 |
15.5 |
|
Teflon® diaphragm and O-Ring with 1/4" NPT (female) 316L stainless steel pressure connection and cap |
||||||||
|
550 |
30" to 3" Hg Vac |
-1 to 0.1 |
0.1 to 0.4" Hg |
0.003 to 0.01 |
80"wc |
0.2 |
225 |
15.5 |
|
551 |
2 to 80"wc |
0.005 to 0.2 |
1 to 4"wc |
0.003 to 0.01 |
80"wc |
0.2 |
225 |
15.5 |
|
552 |
30" Hg Vac to 20 psi |
-1 to 1.4 |
0.2 to 0.5" Hg |
0.007 to 0.02 |
20 |
1.4 |
225 |
15.5 |
|
553 |
0.5 to 20 |
0.03 to 1.4 |
0.1 to 0.2 |
0.007 to 0.014 |
20 |
1.4 |
225 |
15.5 |
|
554 |
0.8 to 30 |
0.06 to 2.1 |
0.1 to 0.3 |
0.007 to 0.02 |
30 |
2.1 |
225 |
15.5 |
|
555 |
2 to 100 |
0.14 to 6.9 |
0.2 to 0.4 |
0.014 to 0.03 |
100 |
6.9 |
225 |
15.5 |
| *Over Range Pressure: The maximum pressure that may be applied continuously without causing damage and maintaining set point repeatability | ||||||||
| ** Proof Pressure: The maximum pressure to which a pressure sensor may be occasionally subjected, which causes no permanent damage. Unit may require calibration. | ||||||||
| Range/Material Code | Adjustable Set Point Range | Deadband | **Proof Pressure | Dial Divisions | |||
|
psi |
bar |
psi |
bar |
psi |
bar |
psi |
|
|
Welded 316L stainless steel bellows with 1/2" NPT (female) pressure connection |
|||||||
|
S126B |
30" Hg Vac to 0 |
-1 to 0 |
0.2 to 0.9" Hg |
7 to 30.5 mbar |
5 |
0.3 |
0.5" Hg |
|
S134B |
30" Hg Vac to 20 |
-1 to 1.4 |
0.2 to 1.2" Hg |
7 to 40.6 mbar |
25 |
1.7 |
1" Hg & 0.5 psi |
|
S137B |
2 to 80"wc |
0.005 to 0.2 |
2 to 10"wc |
5 to 20 mbar |
5 |
0.3 |
2"wc |
|
S144B |
0 to 20 |
0 to 1.4 |
0.1 to 0.5 |
7 to 34.5 mbar |
25 |
1.7 |
0.5 |
|
S146B |
0 to 30 |
0 to 2.1 |
0.1 to 0.6 |
6.9 to 41.4 mbar |
40 |
2.78 |
0.5 |
|
S156B |
0 to 100 |
0 to 6.9 |
0.2 to 0.8 |
13.8 to 55.2 mbar |
125 |
8.6 |
2 |
|
S164B |
0 to 200 |
0 to 13.8 |
0.3 to 2 |
20.7 to 138 mbar |
200 |
13.8 |
5 |
|
Brass bellows with 1/4" NPT (female) nickel-plated brass pressure connection; Models 126 & 134 have zinc-plated steel spring exposed to media |
|||||||
|
126 |
30" Hg Vac to 0 |
-1 to 0 |
0.2" to 0.9" Hg |
7 to 30.5 mbar |
5 |
0.3 |
0.5" Hg |
|
134 |
30" Hg Vac to 20 psi |
-1 to 1.4 |
0.2" to 1.2" Hg |
7 to 40.6 mbar |
25 |
1.7 |
1" Hg & 0.5 psi |
|
137 |
2 to 80"wc |
0.005 to 0.2 |
2 to 10"wc |
5 to 20 mbar |
5 |
0.3 |
2"wc |
|
144 |
0 to 20 |
0 to 1.4 |
0.1 to 0.5 |
6.9 to 34.5 mbar |
25 |
1.7 |
0.5 |
|
146 |
0 to 30 |
0 to 2.1 |
0.1 to 0.6 |
6.9 to 41.4 mbar |
40 |
2.8 |
0.5 |
|
156 |
0 to 100 |
0 to 6.9 |
0.2 to 0.8 |
13.8 to 55.2 mbar |
125 |
8.6 |
2 |
|
164 |
0 to 200 |
0 to 13.8 |
0.3 to 2.0 |
20.7 to 138 mbar |
200 |
13.8 |
5 |
|
Welded 316L stainless steel bellows and 1/4" NPT (female) pressure connection |
|||||||
|
358 |
0 to 200 |
0 to 13.8 |
1.5 to 8 |
0.1 to 0.6 |
250 |
17.2 |
5 |
|
361 |
0 to 300 |
0 to 20.7 |
2 to 9 |
0.1 to 0.6 |
350 |
24.1 |
10 |
|
376 |
0 to 500 |
0 to 34.5 |
3 to 12 |
0.2 to 0.8 |
575 |
39.6 |
10 |
|
303 stainless steel piston and Buna-N O-Ring with 1/4" (female) pressure connection ( not recommended for gas service since drying of the O-Ring seal can allow bleeding of medium into the atmosphere |
|||||||
|
612 |
200 to 3000 |
13.8 to 207 |
40 to 250 |
2.8 to 17.2 |
10000 |
689.5 |
50 |
|
614 |
500 to 6000 |
34.5 to 413.7 |
50 to 400 |
3.4 to 27.6 |
10000 |
689.5 |
100 |
| ** Proof Pressure: The maximum pressure to which a pressure sensor may be occasionally subjected, which causes no permanent damage. Unit may require calibration. | |||||||
| Page | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
For assistance call 978-568-3400