INSTRUMENTATION > FLOW > Series V1 Vortex Flowmeter
Series V1 Vortex Flowmeter CLARK SOLUTIONS

Series V1 Vortex Flowmeter

1/4” to 2” Pipe Size, PVC, CPVC, or PVDF Construction

DESCRIPTION

The operation of the Universal vortex flow meter is based on the vortex shedding principle. As fluid moves around a body, vortices (eddies) are formed and move downstream. They form alternately, from one side to the other, causing pressure fluctuations. These are sensed by a piezoelectric crystal in the sensor tube, and are converted to a 4-20 mA or pulse signal. The frequency of the vortices is directly proportional to the flow. This results in extremely accurate and repeatable measurements with no troublesome moving parts.

A compact two-wire transmitter is a conveniently replaceable plug-in electronics module, located in a corrosion-resistant housing. 

Unlike stainless steel or paddle wheel designs, the vortex sensor is perfect for aggressive or easily contaminated flow media. Applications range from corrosive chemicals to ultrapure water. Although pre-calibrated for specific uses, units can be recalibrated in the field. Potentiometers are provided to adjust for zero and span, anywhere from 10 to 100 percent, without increasing the unit’s minimum readable flow or reducing accuracy.

Refer to our technical bulletin titled “Universal Vortex Flowmeters” for additional design information.

SPECIFICATIONS
GENERAL

Connection: Butt or threaded
Turndown Ratio: 12:1 (except 1/4”: 8:1)
Accuracy: ±1% of designed full scale, ±1% of rate with Vorsite 2000 remote indicator/controller
Repeatability: ±0.25% actual flow
Output Signal: Linear 4-20 mA (pulse options)
Power Supply: 13 to 30 Vdc
CSA Certified: CSA-LR63883
Weatherproof: NEMA-4X
Maximum Overrange: 125% for 1/2 hour, No overrange for
   Hi-Temp units
Response Time: 1.5 sec, first order; a 7.5 sec delay until true
   flow rate is indicated

V1 Vortex Flowmeter Diagram
V2 Graph
Dimensions(Inches)
Size PVC/CPVC PVDF (Butt)
A B C D A B C D
1/4" 3.81 1.75 5.25 2.50 5.90 0.63 4.87 1.31
1/2" 3.81 1.75 7.13 2.50 5.75 0.78 4.87 1.31
3/4" 3.81 1.75 7.63 2.50 5.75 0.94 4.87 1.44
1" 3.92 1.75 8.03 2.50 5.88 1.19 5.09 2.00
1-1/2" 3.90 2.00 8.37 2.50 6.21 1.50 6.24 2.50
2" 4.31 2.00 8.37 2.50 6.60 1.88 6.77 3.00
Max & Min Flow Rates
Max. Fluid Operating Temp./Press.
Size Weight Min. Flow  Max Flow
1/4" 1.5 lbs 0.6 GPM 5 GPM
1/2" 1.6 lbs 1.3 GPM 15 GPM
3/4" 1.7 lbs 2.1 GPM 25 GPM
1" 1.8 lbs 4.2 GPM 50 GPM
1-1/2" 2.7 lbs 8.3 GPM 100 GPM
2" 3.1 lbs 16.7 GPM 200 GPM

Temp

PVC (PSIG) CPVC (PSIG) PVDF (PSIG)
203ºF NR CF CF
150ºF NR 63 PSIG 130 PSIG
100ºF 93 PSIG 120 PSIG 150 PSIG
70ºF 150 PSIG 150 PSIG 150 PSIG
ORDERING INFORMATION
ORDER NUMBER ABCDEF
EXAMPLE:V1-M2A125F100B1P115LCDTPC3
PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS
A=MODEL B=MATERIAL C=MAX FLOW RATING AND LINE SIZE D=LINE CONNECTION E=OUTPUT SIGNAL F=SPAN ADJUSTMENT
Symbol GPM LPM Line Size
Inches MM
V1 M1=PVC A025F5 5 19 1/4 6.35 B1= Butt fusion, PVDF material only X1= 4-20 mA 15 GPM
M2=CPVC A050F15 15 57 1/2 20 E1= Male NPT (PVDF N/A) P1= Pulse output for use with Vorsite 2000 units Please advise maximum flow and unit of measure for proper span adjustment by factory. Specified maximum flow not to exceed 100% of designed flow. Example, 10 gpm = 20 mA
M4=PVDF A075F25 25 95 3/4 25 J1= Male JIS (PVDF N/A)
  A100F50 50 189 1 32 For Female NPT or Union connections, consult factory  
A125F100 100 379 1-1/4 40
A150F100 100 379 1-1/2 50  
A200F200 200 757 2 63
 
SPECIAL OPTIONS  (Multiple choices allowed. List all symbols required, or leave blank for none)
BD= Bi-directional flow (PVC/CPVC Only)
C1= Class 1000 cleaning
HT= High Temp (203°F/95°F max), PVDF only.  Consult factory for CPVC. HT Required in processes exceeding 150°F
Integral LCD rate display:
LCDT= LCD enclosure above horizontal meter
LCDB= LCD enclosure below horizontal meter
LCDR= LCD enclosure right of vertical meter
LCDL= LCD enclosure left of vertical meter
PC3= 3-pin connector, male side only ST= Stainless steel I.D. tag