Series V3 Vortex Flowmeter CLARK SOLUTIONS
Series V3 Vortex Flowmeter
3” to 8” Pipe Size, PVC, CPVC, or PVDF Construction

DESCRIPTION

The operation of the Universal vortex flow meter is based on the vortex shedding principle. As fluid moves around a body, vortices (eddies) are formed and move downstream. They form alternately, from one side to the other, causing pressure fluctuations.  These are sensed by a piezoelectric crystal in the sensor tube, and are converted to a 4-20 mA or pulse signal. The frequency of the vortices is directly proportional to the flow. This results in extremely accurate and repeatable measurements with no troublesome moving parts.

A compact two-wire transmitter is a conveniently replaceable plug-in electronics module, located in a corrosion-resistant housing.

Unlike stainless steel or paddle wheel designs, the vortex sensor is perfect for aggressive or easily contaminated flow media.  Applications range from corrosive chemicals to ultrapure water. Although pre-calibrated for specific uses, units can be recalibrated in the field. Potentiometers are provided to adjust for zero and span, anywhere from 10 to 100 percent, without increasing the unit’s minimum readable flow or reducing accuracy.

Refer to our technical bulletin titled “Universal Vortex Flowmeters” for additional design information.

SPECIFICATIONS
GENERAL

Connection: Flange
Turndown Ratio: 12:1
Accuracy: ±1% of designed full scale, ±1% of rate with Vorsite
   2000 remote indicator/controller
Repeatability: ±0.25% actual flow
Output Signal: Linear 4-20 mA (pulse options)
Power Supply: 13 to 30 Vdc
CSA Certified: CSA-LR63883
Weatherproof: NEMA-4X
Maximum Overrange:
    125% for 1/2 hour
   No overrange for Hi-Temp units
Response Time: 1.5 sec, first order; a 7.5 sec delay until true
   flow rate is indicated

V3 Vortex Flowmeter Diagram 1
Dimensions(Inches)
Size PVDF- ANSI 150 Standard
A B C D
3" 5.72 3.75 12.0 7.5
4" 6.76 4.50 12.0 9.0
6" 8.22 5.50 14.0 11.0
8" 9.81 6.75 15.0 13.5
Size PVDF- JIS 10K Standard
A B C D
3" 5.72 3.74 12.0 7.68
4" 6.76 4.51 12.0 8.27
6" 8.22 5.49 14.0 11.02
8" 9.81 6.75 15.0 12.99
Size PVDF- DIN Standard
A B C D
3" 5.72 3.74 12.0 7.68
4" 6.76 4.51 12.0 8.27
6" 8.22 5.49 14.0 11.02
8" 9.81 6.75 15.0 12.99
Size PVC/CPVC-ANSI 150 Standard
A B C D
3" 5.62 3.75 7.0 7.5
4" 6.25 4.50 8.0 9.0
6" 8.50 5.50 10.0 11.0
8" 9.45 6.75 13.0 13.5
V3 Graph
Max. Fluid Operating Temp./Press.
Max & Min Flow Rates
Temp PVC(PSIG) CPVC(PSIG) PVDF(PSIG)
203ºF NR NR CF
150ºF NR 50 130
100ºF 93 130 150
70ºF 150 150 150
Size Weight Min. Flow Max Flow
3 6 LBS 25 GPM 300 GPM
4 10 LBS 50 GPM 600 GPM
6 16 LBS 100 GPM 1200 GPM
8 29 LBS 208 GPM 2500 GPM
V3 Diagram 2
REPLACEABLE SENSOR

The V3 Series has the unique feature of allowing for sensor replacement without shutting down the process. This applies to all V3 units from 3" through 9".

The electronic module is easily replaced on all Universal vortex flow meters, V1, V2, V3 and V4, without having to interrupt the operation of the pipe system.

ORDERING INFORMATION
ORDER NUMBER ABCDEF
EXAMPLE: V3-M5A600F1200E5RX1900GPMPC3
PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS
A=MODEL B=MATERIAL C=MAX FLOW RATING AND LINE SIZE D=LINE CONNECTION E=OUTPUT SIGNAL F=SPAN ADJUSTMENT
  Line Size
Symbol GPM LPM Inches MM
V3 M1=PVC A300F300 300 1135 3 76.20 E5= "Van Stone" flange style (ANSI 150) RX1= 4-20 mA 900 GPM
M2=CPVC A400F600 600 2300 4 101.6 J5= "Van Stone" flange style (JIS 10K, PVDF only) RP1= Pulse output for use with Vorsite 2000 units Please advise maximum flow and unit of measure for proper span adjustment by factory.
M5=PVDF A600F1200 1200 4600 6 152.4
  A900F2500 2500 9500 8 203.2 D5= "Van Stone" flange style (DIN)
  *STAINLESS STEEL (PVC/CPVC/PVDF only)  
E6= "Van Stone" flange style (ANSI 150) Specified maximum flow not to exceed 100% of designed flow. Example, 900 gpm = 20 mA
J6= "Van Stone" flange style (JIS 10K, PVDF only)
D6= "Van Stone" flange style (DIN)
*Note: PVC and CPVC meters are provided with flanges of the same material.  PVDF meters are provided with PP flanges.
 
SPECIAL OPTIONS  (Multiple choices allowed. List all symbols required, or leave blank for none)
C1= Class 1000 cleaning
HT= High Temp (203°F/95°F max), PVDF only.  Consult factory for CPVC.  HT Required in processes exceeding 150°F
Integral LCD rate display:
LCDT= LCD enclosure above horizontal meter
LCDB= LCD enclosure below horizontal meter
LCDR= LCD enclosure right of vertical meter
LCDL= LCD enclosure left of vertical meter
PC3= 3-pin connector, male side only
ST= Stainless steel I.D. tag
For assistance call 978-568-3400