Series V3 Vortex Flowmeter
3 to 8 Pipe Size, PVC, CPVC, or PVDF Construction
DESCRIPTION
The operation of the Universal vortex flow meter is based on the vortex shedding principle. As fluid moves around a body, vortices (eddies) are formed and move downstream. They form alternately, from one side to the other, causing pressure fluctuations. These are sensed by a piezoelectric crystal in the sensor tube, and are converted to a 4-20 mA or pulse signal. The frequency of the vortices is directly proportional to the flow. This results in extremely accurate and repeatable measurements with no troublesome moving parts.
A compact two-wire transmitter is a conveniently replaceable plug-in electronics module, located in a corrosion-resistant housing.
Unlike stainless steel or paddle wheel designs, the vortex sensor is perfect for aggressive or easily contaminated flow media. Applications range from corrosive chemicals to ultrapure water. Although pre-calibrated for specific uses, units can be recalibrated in the field. Potentiometers are provided to adjust for zero and span, anywhere from 10 to 100 percent, without increasing the units minimum readable flow or reducing accuracy.
Refer to our technical bulletin titled Universal Vortex Flowmeters for additional design information.
|
|
 |
|
|
SPECIFICATIONS
GENERAL
Connection: Flange
Turndown Ratio: 12:1
Accuracy: ±1% of designed full scale, ±1% of rate with Vorsite
2000 remote indicator/controller
Repeatability: ±0.25% actual flow
Output Signal: Linear 4-20 mA (pulse options)
Power Supply: 13 to 30 Vdc
CSA Certified: CSA-LR63883
Weatherproof: NEMA-4X
Maximum Overrange:
125% for 1/2 hour
No overrange for Hi-Temp units
Response Time: 1.5 sec, first order; a 7.5 sec delay until true
flow rate is indicated
|
|
 |
|
|
|
|
| Dimensions(Inches) |
|
|
| Size |
PVDF- ANSI 150 Standard |
| A |
B |
C |
D |
| 3" |
5.72 |
3.75 |
12.0 |
7.5 |
| 4" |
6.76 |
4.50 |
12.0 |
9.0 |
| 6" |
8.22 |
5.50 |
14.0 |
11.0 |
| 8" |
9.81 |
6.75 |
15.0 |
13.5 |
|
|
| Size |
PVDF- JIS 10K Standard |
| A |
B |
C |
D |
| 3" |
5.72 |
3.74 |
12.0 |
7.68 |
| 4" |
6.76 |
4.51 |
12.0 |
8.27 |
| 6" |
8.22 |
5.49 |
14.0 |
11.02 |
| 8" |
9.81 |
6.75 |
15.0 |
12.99 |
|
|
| Size |
PVDF- DIN Standard |
| A |
B |
C |
D |
| 3" |
5.72 |
3.74 |
12.0 |
7.68 |
| 4" |
6.76 |
4.51 |
12.0 |
8.27 |
| 6" |
8.22 |
5.49 |
14.0 |
11.02 |
| 8" |
9.81 |
6.75 |
15.0 |
12.99 |
|
| Size |
PVC/CPVC-ANSI 150 Standard |
| A |
B |
C |
D |
| 3" |
5.62 |
3.75 |
7.0 |
7.5 |
| 4" |
6.25 |
4.50 |
8.0 |
9.0 |
| 6" |
8.50 |
5.50 |
10.0 |
11.0 |
| 8" |
9.45 |
6.75 |
13.0 |
13.5 |
|
|
 |
|
|
|
| Max. Fluid Operating Temp./Press. |
|
|
| Max & Min Flow Rates |
|
| Temp |
PVC(PSIG) |
CPVC(PSIG) |
PVDF(PSIG) |
| 203ºF |
NR |
NR |
CF |
| 150ºF |
NR |
50 |
130 |
| 100ºF |
93 |
130 |
150 |
| 70ºF |
150 |
150 |
150 |
|
|
|
| Size |
Weight |
Min. Flow |
Max Flow |
| 3 |
6 LBS |
25 GPM |
300 GPM |
| 4 |
10 LBS |
50 GPM |
600 GPM |
| 6 |
16 LBS |
100 GPM |
1200 GPM |
| 8 |
29 LBS |
208 GPM |
2500 GPM |
|
|
|
|
|
 |
|
REPLACEABLE SENSOR
The V3 Series has the unique feature of allowing for sensor replacement without shutting down the process. This applies to all V3 units from 3" through 9".
The electronic module is easily replaced on all Universal vortex flow meters, V1, V2, V3 and V4, without having to interrupt the operation of the pipe system.
|
|
ORDERING INFORMATION
ORDER NUMBER ABCDEF
EXAMPLE: V3-M5A600F1200E5RX1900GPMPC3 |
|
| PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS |
| A=MODEL |
B=MATERIAL |
C=MAX FLOW RATING AND LINE SIZE |
D=LINE CONNECTION |
E=OUTPUT SIGNAL |
F=SPAN ADJUSTMENT |
| |
Line Size |
| Symbol |
GPM |
LPM |
Inches |
MM |
| V3 |
M1=PVC |
A300F300 |
300 |
1135 |
3 |
76.20 |
E5= "Van Stone" flange style (ANSI 150) |
RX1= 4-20 mA |
900 GPM |
| M2=CPVC |
A400F600 |
600 |
2300 |
4 |
101.6 |
J5= "Van Stone" flange style (JIS 10K, PVDF only) |
RP1= Pulse output for use with Vorsite 2000 units |
Please advise maximum flow and unit of measure for proper span adjustment by factory. |
| M5=PVDF |
A600F1200 |
1200 |
4600 |
6 |
152.4 |
| |
A900F2500 |
2500 |
9500 |
8 |
203.2 |
D5= "Van Stone" flange style (DIN) |
| |
*STAINLESS STEEL (PVC/CPVC/PVDF only) |
|
| E6= "Van Stone" flange style (ANSI 150) |
Specified maximum flow not to exceed 100% of designed flow. Example, 900 gpm = 20 mA |
| J6= "Van Stone" flange style (JIS 10K, PVDF only) |
| D6= "Van Stone" flange style (DIN) |
| *Note: PVC and CPVC meters are provided with flanges of the same material. PVDF meters are provided with PP flanges. |
| |
| SPECIAL OPTIONS (Multiple choices allowed. List all symbols required, or leave blank for none) |
| C1= Class 1000 cleaning |
| HT= High Temp (203°F/95°F max), PVDF only. Consult factory for CPVC. HT Required in processes exceeding 150°F |
| Integral LCD rate display: |
| LCDT= LCD enclosure above horizontal meter |
| LCDB= LCD enclosure below horizontal meter |
| LCDR= LCD enclosure right of vertical meter |
| LCDL= LCD enclosure left of vertical meter |
| PC3= 3-pin connector, male side only |
| ST= Stainless steel I.D. tag |
|
|
For assistance call 978-568-3400
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|