VS1 3/4” & 1” Flosonex™ Ultrasonic Vortex Flowmeter CLARK SOLUTIONS
VS1 3/4" & 1" Flosonex™ Ultrasonic Vortex Flowmeter
3/4" & 1" Pipe Size, PFA or PVDF Construction

DESCRIPTION

FloSonex vortex flow meters are designed for accurate flow rate measurement of ultra-pure and ultra-aggressive liquids. The flow sensor consists of a solid flow tube and a removable PTFE or PVDF sensor. The flow tube is compatible with most processing liquids including DI water, hot (up to 160 °C), 95% sulfuric acid, phosphoric acid, SC1, SC2, “Piranha,” and many others. The flow tube is completely passive containing no moving parts. The only active components are the two ultrasonic transducers sealed within the sensors. The sensors are easily removed from the flow tube with a blade screwdriver. All repairs may be made without shutting the process down. Each FloSonex unit is permanently calibrated at the factory. Removal of the sensors does not affect calibration. In t e unlikely event of an electronics failure, calibration data may be downloaded to the new module.

Refer to our technical bulletin titled "Flosonex™ Ultrasonic Vortex Flowmeters" for additional design information.

SPECIFICATIONS
GENERAL

Size: 3/4" tubing, 1” tubing, full bore or low flow
Material: PFA , PVDF
Flow Range:
   3/4" tubing: 4 to 75 lpm (1.0 to 19 gpm)
   1” tubing, full bore: 6 to 150 lpm (1.4 to 39 gpm)
   1” tubing, low flow: 4 to 75 lpm (1.0 to 19 gpm)
Accuracy: 0.75% of user-defined span
Repeatability: 0.25% of reading/point
Temperature/Pressure Ratings:

Max. Temp PVDF PFA
356ºF NA 20 PSIG
203ºF CF 66 PSIG
150ºF 130 PSIG 93.5 PSIG
100ºF 150 PSIG 110 PSIG
70ºF 150 PSIG 110 PSIG
Graph

Output Signal: 4–20 mA (sourcing output, uses internal power)
   400 Ohm max loop resistance at 10 Vdc PS
   1400 Ohm max loop resistance at 24 Vdc PS
Power: 10–30 Vdc at 100 mA

      A B1 B2 C D E1 E2
3/4" PFA Flow Meter Remote Electronics 4.5 4.0 - 2.9 2.4 2.9 -
Direct Mount 4.5 4.0 5.8 2.9 2.4 2.9 4.5
1" PFA Flow Meter Remote Electronics 4.5 4.0 - 2.9 2.4 2.9 -
Direct Mount 4.5 4.0 5.8 2.9 2.4 2.9 4.5
ORDERING INFORMATION
ORDER NUMBER ABCDEF
EXAMPLE: VS1-M5A100L75F1PVDMX1
PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS
A=MODEL B= MATERIAL C=MAX FLOW RATING AND LINE SIZE D=LINE CONNECTION E=YOKE/ ELECTRONICS F=OUTPUT SIGNAL
Symbol GPM LPM Line Size
Inches MM
VS1 M7=PFA A075L75 19 75 3/4 25 F1= Flare End PVRM= PVDF/ Remote Mount X1= 4-20 mA
M5=PVDF (CF) A100L75 19 75 1 32 S1 = Sanitary end (PVDF only) TFRM= PTFE/ Remote Mount P1= Pulse
  A100L100 39 150 1 32 B1 = Butt end (consult factory) PVDM= PVDF/ Direct Mount  
 
F=SPECIAL OPTION
CA5M= 5 Meter Cable (Remote Electronics Only)
For assistance call 978-568-3400