VS2 1/2” To 4” Flosonex™ Ultrasonic Vortex Flowmeter CLARK SOLUTIONS
VS2 1/2" To 4"Flosonex™ Ultrasonic Vortex Flowmeter
1/2” to 4” Pipe Size, PVDF Construction

DESCRIPTION

FloSonex vortex flow meters are designed for accurate flow rate measurement of ultra-pure and ultra-aggressive liquids.  The flow sensor consists of a solid flow tube and a removable PVDF sensor. The flow tube, fabricated from PVDF, is compatible with many liquids and the flow tube is completely passive containing no moving parts. The only active components are the two ultrasonic transducers sealed within the sensors. The sensors are easily removed from the flow tube with a blade screwdriver.  All repairs may be made without shutting the process down. Each FloSonex unit is permanently calibrated at the factory.  Removal of the sensors does not affect calibration. In the unlikely event of an electronics failure, calibration data may be downloaded to the new module.

Refer to our technical bulletin titled “Flosonex™ Ultrasonic Vortex Flowmeters” for additional design information.

SPECIFICATIONS
GENERAL

Size: 1/2" to 4”, Wafer Connection, ANSI 150, DIN or JIS
Material: PVDF
Flow Range:

Size Min. Flow Max Flow
1/2" 1 GPM 15 GPM
3/4" 1.25 GPM 25 GPM
1" 2.5 GPM 50 GPM
1-1/2" 5 GPM 100 GPM
2" 10 GPM 200 GPM
3" 15 GPM 300 GPM
4" 25 GPM 600 GPM
Graph

Accuracy: 0.75% of user-defined span
Repeatability: 0.25% of reading/point
Temperature/Pressure Ratings:
    16 bar @ 20°C (230 psi @ 70°F) (PVDF only)
    10 bar @ 38°C (150 psi @ 100°F) (PVDF only)
    8.9 bar @ 66°C (130 psi @ 150°F) (PVDF only)
    5.7 bar @ 95°C ( 83 psi @ 203°F) (PVDF only)
Output Signal: 4–20 mA (sourcing output, uses internal power)
    400 Ohm max loop resistance at 10 Vdc PS
    1400 Ohm max loop resistance at 24 Vdc PS
Power: 10–30 Vdc at 100 mA

Size A B C D E F
1/2 0.75 1.50 6.25 3.26 2.00 4.50
3/4 1.00 2.75 6.75 3.26 2.00 4.50
1 1.25 3.12 7.10 3.26 2.25 4.50
1-1/2 1.50 3.90 8.50 3.26 3.25 4.50
2 2.00 5.00 9.00 3.26 3.25 4.50
3 2.50 6.17 10.50 3.26 4.25 4.50
4 3.00 7.40 11.50 3.26 4.00 4.50
ORDERING INFORMATION
ORDER NUMBER ABCDEFG
EXAMPLE: VS2-M5A100F50J3RSX1XXX
PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS
A=MODEL B=
MATERIAL
C=MAX FLOW RATING AND LINE SIZE D=LINE CONNECTION E=VORTEX SIGNAL F=OUTPUT SIGNAL G=FULL SPAN READING
Symbol GPM LPM Line Size
Inches MM
VS2 M5= PVDF A050F15 15 56 1/2 20 E3=ANSI 150 RS = Replaceable Sensor X1= 4-20 mA *XXX
A075F25 25 94 3/4 25 D3=DIN P1= Pulse *Specify desired flow value at full span. For example, for order range A100F50 specify a value up to 50 GPM. If 40 is specified the output will be 20 mA at 40 GPM if 4-20 mA output is specified.
A100F50 50 189 1 32 J3=JIS  
A150F100 100 379 1-1/2 40  
A200F200 200 757 2 50
A300F300 300 1135 3 75
A400F600 600 2271 4 110
 
F=SPECIAL OPTIONS (Multiple choices allowed. List all symbols required, or leave blank for none)
C1 = Class 1000 cleaning
ST = Stainless steel ID tag
PL = Plastic tag
PC3 = 3-pin connector
For assistance call 978-568-3400