DESCRIPTION

The operation of the RVL vortex flow meter is based on the vortex shedding principle. As fluid moves around a body, vortices (eddies) are formed and move downstream. They form alternately, from one side to the other, causing pressure fluctuations. These are sensed by a piezoelectric crystal in the sensor tube, and are converted to a 4-20 mA, 0-5 VDC or pulse signal.

The frequency of the vortices is directly proportional to the flow. This results in extremely accurate and repeatable measurements with no troublesome moving parts.

Unlike stainless steel or paddle wheel designs, the vortex sensor is perfect for aggressive or easily contaminated flow media.

Applications include flow monitoring and control of corrosive chemicals and slurries in chemical processing, water/wastewater, and DI water.

SPECIFICATIONS

IN-LINE FLOWMETERS

Media: Liquids
Connection: Butt or NPT Male thread
Turndown Ratio: 12:1 (except 1/4": 8:1)
Accuracy: ±1% of full scale, 4-20 mA or 0-5 VDC;
		±2% of full scale, frequency pulse
Repeatability: ±0.25% actual flow
Output Signal: 4-20 mA, 0-5 Vdc or frequency pulse (source-sink driver; 
		1A source / 1.5A sink; typical output resistance 10 Ohms) 
		Power Supply: 13 to 30 Vdc
Weatherproof: NEMA-4X (IP 66)
Maximum Overrange: 125% for 1/2 hour,
		No overrange for Hi-Temp units
Response Time: 2 seconds minimum, step change in flow 
CSA: CSA File: 215035
		CSA Standard C22.2 No. O-M and No. 142-M

Dimensions (Inches)
Size PVC/CPVC PVDF (Butt)
A B C D A B C D
¼" 3.81 1.75 5.25 2.50 5.90 0.63 4.87 1.31
½" 3.81 1.75 7.13 2.50 5.75 0.78 4.87 1.31
¾" 3.81 1.75 7.63 2.50 5.75 0.94 4.87 1.44
1" 3.92 1.75 8.03 2.50 5.88 1.19 5.09 2.00
1½" 3.90 2.00 8.37 2.50 6.21 1.50 6.24 2.50
2" 4.31 2.00 8.37 2.50 6.60 1.88 6.77 3.00

Vortex diagram

Max. Fluid Operating Temperature
Temp. PVC (PSIG) CPVC (PSIG) PVDF (PSIG)
203°F NR 24 40
150°F NR 63 130
100°F 93 120 150
70°F 150 150 150
Max. & Min Flow
Size Weight Min. Flow Max. Flow
¼" 1.5lbs 0.6GPM 5GPM
½" 1.6lbs 1.3GPM 15GPM
¾" 1.7lbs 2.1GPM 25GPM
1" 1.8lbs 4.2GPM 50GPM
1½" 2.7lbs 8.3GPM 100GPM
2" 3.1lbs 16.7GPM 200GPM


ORDERING INFORMATION

ORDER NUMBER RVL-ABCDEF
EXAMPLE: RVL-050-N-4-X-N-1

A=Size/Range B=Body Style & End Connections C=Body Material D=Output E=Options1 F=Display
Size/Range Symbol GPM LPM Line Size
Inches MM
025 5 19 ¼ 6.35 B= Butt End Connection* 1=PVC X= 4-20 mA (standard) N= None N= None
050 15 57 ½ 20 N= NPT (Male) Thread 2=CPVC C= Class 1000 Cleaning 1=Top mount LCD
075 25 95 ¾ 25   4=PVDF P= Frequency Pulse H= High Temperature rated: 203°F (95°C)2 2=Bottom mount LCD
100 50 189 1 32 V= 0-5 Vdc S= Stainless Steel Tag 3=Right mount LCD
150 100 379 50 3= 3-Pin Connector 4= Left mount LCD
200 200 757 2 63
*available with PVDF material only
1 Multiple options may be selected
2 High Temperature option ONLY available with CPVC and PVDF body materials


CLARK SOLUTIONS

Series RVL Vortex Flowmeter

SPECIFICATIONS

WAFER MOUNTING

Medium: Liquids
Connection: Wafer
Turndown Ratio: 12:1 (except ¼": 8:1)
Accuracy: ±1% of full scale, 4-20 mA or 0-5 VDC;
		±2% of full scale, frequency pulse
Repeatability: ±0.25% actual flow
Output Signal: 4-20 mA, 0-5 Vdc or frequency pulse (source-sink 
		driver; 1A source / 1.5A sink; typical output resistance 
		10 Ohms)
Power Supply: 13 to 30 Vdc
Weatherproof: NEMA-4X (IP 66)
Maximum Overrange: 125% for ½ hour, no overrange for Hi-Temp units
Response Time: 2 seconds minimum, step change in flow
CSA: CSA File: 215035
		CSA Standard C22.2 No. O-M and No. 142-M
WAFER MOUNTING

Max. Fluid Operating Temperature/Pressure
Temp. PVC (PSIG) PP (PSIG) CPVC (PSIG) PVDF (PSIG)
203°F NR NR CF CF
150°F NR 90 100 130
100°F 400 130 130 150
70°F 150 150 150 150
Max. & Min Flow Rates
Size Weight Min. Flow Max. Flow
½" 0.8lbs 1.3GPM 15GPM
¾" 0.9lbs 2.1GPM 25GPM
1" 1.1lbs 4.2GPM 50GPM
1½" 1.7lbs 8.3GPM 100GPM
2" 2.6lbs 16.7GPM 200GPM
3" 4.8lbs 25.0GPM 300GPM

Dimensions (Inches)
Size PVDF – ANSI 150 Standard
A B C D
½" 5.85 0.78 2.03 1.75
¾" 5.90 0.94 2.03 2.13
1" 5.69 1.19 2.25 2.47
1½" 6.00 1.50 2.63 3.25
2" 6.37 1.88 3.22 4.00
3" 6.88 2.50 4.25 5.24

Dimensions diagram


ORDERING INFORMATION

ORDER NUMBER RVL-ABCDEF
EXAMPLE: RVL-050-W-4-X-N-1

A=Size/Range B=Body Style & End Connections C=Body Material D=Output E=Options1 F=Display
Size/Range Symbol GPM LPM Line Size
Inches MM
050 15 57 ½ 20 W= Wafer (mounts between flanges) 1=PVC X= 4-20 mA (standard) N= None N= None
050 15 57 ½ 20 2=CPVC C= Class 1000 Cleaning 1=Top mount LCD
075 25 95 ¾ 25 3= Polypropylene P= Frequency Pulse H= High Temperature rated: 203°F (95°C)2 2=Bottom mount LCD
100 50 189 1 32 V= 0-5 Vdc S= Stainless Steel Tag 3=Right mount LCD
150 100 379 50 4=PVDF 3= 3-Pin Connector 4= Left mount LCD
200 200 757 2 63
1 Multiple options may be selected
2 High Temperature option ONLY available with CPVC and PVDF body materials


CLARK SOLUTIONS

Series RVL Vortex Flowmeter

SPECIFICATIONS

IN-LINE FLARE END

Medium: Liquids
Connection: Tube (flare-end), Requires two flare tubing nuts (not included)
Turndown Ratio:
		½" size = 8:1
		¾" size = 12:1
		1" size = 12:1
Accuracy: ±1% of full scale, 4-20 mA or 0-5 VDC;
		±2% of full scale, frequency pulse
Repeatability: ±0.25% actual flow
Output Signal: 4-20 mA, 0-5 Vdc or frequency pulse (source-sink driver;
		1A source / 1.5A sink; typical output resistance 10 Ohms)
Power Supply: 13 to 30 Vdc
Weatherproof: NEMA-4X (IP 66)
Maximum Overrange: 125% for ½ hour, no overrange for Hi-Temp units
Response Time: 2 seconds minimum, step change in flow
CSA: CSA File: 215035
		CSA Standard C22.2 No. O-M and No. 142-M
IN-LINE FLARE END

Max. Fluid Operating Temperature/Pressure
Temp. PVDF (PSIG)
203°F 20
150°F 37
100°F 67
70°F 150
Max. & Min Flow Rates
Size Weight Min. Flow Max. Flow
½" 1.5lbs 0.6GPM 5GPM
¾" 1.6lbs 1.3GPM 15GPM
1" 1.7lbs 2.1GPM 25GPM


Dimensions (Inches)
Size A B C
½" 1.31 6.25 4.87
¾" 1.31 6.25 4.66
1" 1.44 6.59 5.42

Dimensions diagram


ORDERING INFORMATION

ORDER NUMBER RVL-ABCDEF
EXAMPLE: RVL-050L-W-4-X-N-1

A=Size/Range B=Body Style & End Connections C=Body Material D=Output E=Options1 F=Display
Size/Range Symbol GPM LPM Line Size
Inches MM
050L 15 57 ½ 20 W= Wafer (mounts between flanges) 4=PVDF X= 4-20 mA (standard) N= None N= None
075L 25 95 ¾ 25 C= Class 1000 Cleaning 1=Top mount LCD
100L 50 189 1 32 P= Frequency Pulse S= Stainless Steel Tag 2=Bottom mount LCD
V= 0-5 Vdc 3= 3-Pin Connector 3=Right mount LCD
4= Left mount LCD
1 Multiple options may be selected

In-Line Flow Meters for Liquids graph

WaferFlow Meters for Liquids graph

In-Line Flare End Flow Meters for Liquids graph


Series RVL Vortex Flowmeter