INSTRUMENTATION > FLOW > WMX101 Flanged Magnetic Flow Transmitter
CLARK SOLUTIONS

WMX101 Flanged Magnetic Flow Transmitter

4" to 10" Pipe, F.S. flow ranges 500 to 1800 GPM

DESCRIPTION

The WMX101 is a flanged electromagnetic flow meter for use in utility or industrial water and wastewater applications. An ingenious economical design makes it an ideal meter for applications where propeller meters have been the norm, but with no moving parts to wear the magnetic flow meter minimizes maintenance costs and dramatically decreases total cost of ownership.

For simplicity, no field programming is required. Large, domed measurement and grounding electrodes discourage fouling. Rate and total indication are standard. There is a solid-state pulse output for connection to standard telemetry systems or to an external 4-20 mA converter.

Power required for the meter is within easy range of a solar panel, which can be ordered as an accessory or obtained locally. A shielded power/pulse output cable with DIN connection is included with the meter. Optional features include immersible electronics for occasional vault flooding. The AO55 pulse to analog converter can be added where a 4-20 mA signal is required.

Click here for info on our other flow transmitters.

SPECIFICATIONS

Pipe Sizes: 4", 6", 8", 10"
Flanges: AWWA 150 lb. drilling
Pressure: 150 psi working pressure
Temperature: 10°F to 130°F
Environmental: NEMA 4X standard, short term 
     immersible option available
Accuracy (% of reading): ±1%, 10 to 100%; ±2%, 10% to cutoff
Materials:
     Body: Welded steel, epoxy powder coated
     Liner: HDPE
     Electronics Housing: Diecast Aluminum
     Electrodes: T316 stainless steel
Display:
6 Digit Rate of Flow Display 8 Digit Totalizer Display
Units Units
Gallons/Minute Gallons
Million Gallons/Minute Gallons X 1000
Liters/Second Cubic Meter
Cubic Feet Per minute Cubic Feet
Power: 12-24 VDC, 30 mA max. Output Signal: Current-sinking pulse, opto-isolated, 24 VDC, 10 mA max Empty Pipe Detection: Hardware/software, conductivity-based Flow Range:
Flow Range (GPM) Pipe Size
4" 6" 8" 10"
Min. 12 32 60 100
Max. 500 1200 1500 1800
DIMENSIONS (MM) Magnetic Flow Transmitter Dimensions
Meter Size WMX101 L H T Weight (Kg)
-400 250 188 15.88 10.5
-600 300 216 17.48 14.5
-800 350 241 17.48 21.5
-1000 450 264 17.48 32

RSP5 SOLAR PANEL OPTION

Magnetic Flow Transmitter Solar PanelFlow Sensor
The RSP5 5W solar panel makes it possible to use WMX101 flowmeters in remote applications where a reliable source of electricity is not available or practical. The RSP5 is intended for use with a standard 12V, 50 Amp-hour deep cycle battery (not included). It comes standard with a charge controller and galvanized steel mounting hardware and provides a 90-day back-up power supply for periods of darkness. Typical current at design operating point: 330 mA Typical voltage at design operating point: 15 V Weight: 3.63 Kg (8 lb) Overall height: 371 mm (14.625") Overall Width: 346 mm (13.625")

ORDERING INFORMATION ORDER NUMBER ABCDE EXAMPLE: WMX101-800GPMGA
PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS
A B C D E
Model Size Options Rate of Flow Units Totalizing Units
WMX101 400= 4" 00= None GPM=Gallons/Minute GA=Gallons
600=6" 45=Immersible MGD= Million Gallons.Day GT=Gallons X 1000
800=8" 39=Grooved Ends LPS=Liters/Second CF=Cubic Feet
1000=10" 38=Bi-Directional CFM= Cubic Feet/Minute CM=Cubic Meter

Accessories

PLEASE CALL 1-800-253-2497 TO ORDER THESE ITEMS
A055W Blind 4-20 mA converter, wall mount
PC42 Dual power supply, 110-115 VAC, 24 VDC
PC3 Power converter, plug-in, 110-115 VAC, 24 VDC
RSP5W Solar panel kit, 5 Watt
31051 Extra cable, specify length
31090 Grounding ring 4"
31091 Grounding ring 6"
31092 Grounding ring 8"
31093 Grounding ring 10"